Exam 24: Expansion Devices
Exam 1: Heat and Pressure45 Questions
Exam 2: Matter and Energy32 Questions
Exam 3: Refrigeration and Refrigerants38 Questions
Exam 4: General Safety Practices31 Questions
Exam 5: Tools and Equipment30 Questions
Exam 6: Fasteners32 Questions
Exam 7: Tubing and Piping45 Questions
Exam 8: Leak Detection, System Evacuation and System Clean-Up33 Questions
Exam 9: Refrigerant and Oil Chemistry and Managementrecovery, Recycling, Reclaiming, and Retrofitting39 Questions
Exam 10: System Charging27 Questions
Exam 11: Calibrating Instruments34 Questions
Exam 12: Basic Electricity and Magnetism46 Questions
Exam 13: Introduction to Automatic Controls30 Questions
Exam 14: Automatic Control Components and Applications34 Questions
Exam 15: Troubleshooting Basic Controls33 Questions
Exam 16: Advanced Automatic Controlsdirect Digital Controls Ddc and Pneumatics35 Questions
Exam 17: Types of Electric Motors36 Questions
Exam 18: Application of Motors33 Questions
Exam 19: Motor Controls31 Questions
Exam 20: Troubleshooting Electric Motors30 Questions
Exam 21: Evaporators and the Refrigeration System37 Questions
Exam 22: Condensers35 Questions
Exam 23: Compressors35 Questions
Exam 24: Expansion Devices29 Questions
Exam 25: Special Refrigeration System Components35 Questions
Exam 26: Application of Refrigeration Systems34 Questions
Exam 27: Commercial Ice Machines35 Questions
Exam 28: Special Refrigeration Applications27 Questions
Exam 29: Troubleshooting and Typical Operating Conditions for Commercial Refrigeration34 Questions
Exam 30: Electric Heat29 Questions
Exam 31: Gas Heat27 Questions
Exam 32: Oil Heat35 Questions
Exam 33: Hydronic Heat35 Questions
Exam 34: Indoor Air Quality35 Questions
Exam 35: Comfort and Psychrometrics35 Questions
Exam 36: Refrigeration Applied to Air Conditioning31 Questions
Exam 37: Air Distribution and Balance35 Questions
Exam 38: Installation32 Questions
Exam 39: Residential Energy Auditing35 Questions
Exam 40: Typical Operating Conditions25 Questions
Exam 41: Troubleshooting28 Questions
Exam 42: Heat Gain and Heat Loss in Buildings35 Questions
Exam 43: Air Source Heat Pumps35 Questions
Exam 44: Geothermal Heat Pumps31 Questions
Exam 45: Domestic Refrigerators and Freezers35 Questions
Exam 46: Room Air Conditioners34 Questions
Exam 47: High-Pressure, Low-Pressure, and Absorption Chilled-Water Systems35 Questions
Exam 48: Cooling Towers and Pumps30 Questions
Exam 49: Operation, Maintenance, and Troubleshooting of Chilled-Water Air Conditioning Systems28 Questions
Exam 50: Commercial Rooftop, Packaged, Variable Refrigerant Flow, and Variable Air Volume Systems35 Questions
Select questions type
A thermostatic expansion valve meters refrigerant flow to the evaporator based on the ____.
(Multiple Choice)
4.9/5
(37)
AXVs are usually found on smaller equipment with somewhat constant evaporator loads .
(True/False)
4.8/5
(38)
Explain why the external equalizer line on a thermostatic expansion valve should always be installed after (downstream of) the thermal bulb.
(Essay)
4.8/5
(38)
The automatic expansion valve maintains a constant ____________________ in the evaporator .
(Short Answer)
4.8/5
(31)
If the thermal bulb assembly develops a leak, what will occur?
(Multiple Choice)
4.8/5
(39)
The pin or valve port piston of the electronic step-motor expansion valve can move in a linear motion of 0.0000783 in./step .
(True/False)
4.9/5
(34)
The pressure-limiting TXV is desirable in low temperature applications because it keeps the suction pressure to the compressor down during hot pulldowns .
(True/False)
4.9/5
(30)
Showing 21 - 29 of 29
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)