Exam 50: Commercial Rooftop, Packaged, Variable Refrigerant Flow, and Variable Air Volume Systems
Exam 1: Heat and Pressure45 Questions
Exam 2: Matter and Energy32 Questions
Exam 3: Refrigeration and Refrigerants38 Questions
Exam 4: General Safety Practices31 Questions
Exam 5: Tools and Equipment30 Questions
Exam 6: Fasteners32 Questions
Exam 7: Tubing and Piping45 Questions
Exam 8: Leak Detection, System Evacuation and System Clean-Up33 Questions
Exam 9: Refrigerant and Oil Chemistry and Managementrecovery, Recycling, Reclaiming, and Retrofitting39 Questions
Exam 10: System Charging27 Questions
Exam 11: Calibrating Instruments34 Questions
Exam 12: Basic Electricity and Magnetism46 Questions
Exam 13: Introduction to Automatic Controls30 Questions
Exam 14: Automatic Control Components and Applications34 Questions
Exam 15: Troubleshooting Basic Controls33 Questions
Exam 16: Advanced Automatic Controlsdirect Digital Controls Ddc and Pneumatics35 Questions
Exam 17: Types of Electric Motors36 Questions
Exam 18: Application of Motors33 Questions
Exam 19: Motor Controls31 Questions
Exam 20: Troubleshooting Electric Motors30 Questions
Exam 21: Evaporators and the Refrigeration System37 Questions
Exam 22: Condensers35 Questions
Exam 23: Compressors35 Questions
Exam 24: Expansion Devices29 Questions
Exam 25: Special Refrigeration System Components35 Questions
Exam 26: Application of Refrigeration Systems34 Questions
Exam 27: Commercial Ice Machines35 Questions
Exam 28: Special Refrigeration Applications27 Questions
Exam 29: Troubleshooting and Typical Operating Conditions for Commercial Refrigeration34 Questions
Exam 30: Electric Heat29 Questions
Exam 31: Gas Heat27 Questions
Exam 32: Oil Heat35 Questions
Exam 33: Hydronic Heat35 Questions
Exam 34: Indoor Air Quality35 Questions
Exam 35: Comfort and Psychrometrics35 Questions
Exam 36: Refrigeration Applied to Air Conditioning31 Questions
Exam 37: Air Distribution and Balance35 Questions
Exam 38: Installation32 Questions
Exam 39: Residential Energy Auditing35 Questions
Exam 40: Typical Operating Conditions25 Questions
Exam 41: Troubleshooting28 Questions
Exam 42: Heat Gain and Heat Loss in Buildings35 Questions
Exam 43: Air Source Heat Pumps35 Questions
Exam 44: Geothermal Heat Pumps31 Questions
Exam 45: Domestic Refrigerators and Freezers35 Questions
Exam 46: Room Air Conditioners34 Questions
Exam 47: High-Pressure, Low-Pressure, and Absorption Chilled-Water Systems35 Questions
Exam 48: Cooling Towers and Pumps30 Questions
Exam 49: Operation, Maintenance, and Troubleshooting of Chilled-Water Air Conditioning Systems28 Questions
Exam 50: Commercial Rooftop, Packaged, Variable Refrigerant Flow, and Variable Air Volume Systems35 Questions
Select questions type
The term enthalpy refers to the total heat content in the air, which accounts for both the temperature (sensible heat portion) and the moisture content (latent heat portion) of the air.
(True/False)
4.9/5
(41)
The unit's location should be carefully selected so the system's operation is not adversely affected by air being able to ____ the condenser coil.
(Multiple Choice)
5.0/5
(30)
By utilizing a strategy called demand control ventilation, DCV, the amount of outside air being brought into the building can be varied based on the actual occupancy level in the structure.
(True/False)
4.8/5
(28)
If the curb is mounted as part of a new construction process, it can be assembled and installed as soon as the ____ support system is in place.
(Multiple Choice)
4.9/5
(44)
By tapping his fist on his ____, the crew member is telling the crane operator to use the main hoist.
(Multiple Choice)
4.8/5
(41)
____ are intended to help provide the correct amount of ventilation and also help reduce cooling costs by allowing outside air to be introduced to the conditioned space when conditions are correct.
(Multiple Choice)
4.9/5
(44)
How do variable refrigerant flow (VRF) systems modulate the volume of refrigerant that is pumped through the system?
(Essay)
4.8/5
(37)
The economizer is able to increase or decrease the amount of outside air that is brought into the structure with two ____.
(Multiple Choice)
4.9/5
(27)
The rooftop unit houses the fans and blowers that move air through the heating and cooling portions of the unit but not through the condenser.
(True/False)
4.8/5
(44)
Although packaged air-conditioning equipment comes precharged with refrigerant and no field piping must be done, the installation of a rooftop package unit involves many steps and can be very dangerous.
(True/False)
4.9/5
(33)
The amount of refrigerant indicated on the ____ is the total refrigerant charge for the unit, not simply a holding charge as in the case of a split-type system.
(Multiple Choice)
4.8/5
(40)
Some roofs are bonded, which are roofs that carry a written warranty or insurance policy that protects the building owner in the event damage from leaks occurs.
(True/False)
4.8/5
(43)
The water coil in a dry cooler can contain 100% water or can be a mix of water with ____________________.
(Short Answer)
5.0/5
(39)
Many rooftop package units are equipped with multiple ____________________ fans.
(Short Answer)
4.9/5
(39)
Showing 21 - 35 of 35