Exam 8: Overload Units
Exam 1: Electric Induction Theory20 Questions
Exam 2: Induction Motor Overview21 Questions
Exam 3: Three-Phase Motor Theory20 Questions
Exam 4: Single-Phase Induction Motors20 Questions
Exam 5: Electric Motor Connections24 Questions
Exam 6: Motor Nameplates23 Questions
Exam 7: Magnetic Relays and Contactors20 Questions
Exam 8: Overload Units20 Questions
Exam 9: Magnetic Motor Starters21 Questions
Exam 10: Motor Starter Circuits20 Questions
Exam 11: Motor Control Circuit Ladder Diagram Documentation23 Questions
Exam 12: Two-Wire Motor Control20 Questions
Exam 13: Three-Wire Motor Control20 Questions
Exam 14: Control Circuits20 Questions
Exam 15: Variable Frequency Drive Principles24 Questions
Exam 16: Commissioning a VFD20 Questions
Select questions type
Overload units are designed with an inverse time-delay function.
Free
(True/False)
4.8/5
(38)
Correct Answer:
True
The absolute best way to assure adequate motor protection is to consult the cover of the motor ____, the motor control center, or the manufacturers catalog at the time of installation.
Free
(Multiple Choice)
4.8/5
(34)
Correct Answer:
A
The eutectic alloy in the heater barrel element is a material that goes from a solid state to a liquid state without going through an intermediate ____ stage.
Free
(Multiple Choice)
4.8/5
(33)
Correct Answer:
C
Overload protection is designed with inverse time-delay trip characteristics.This means the ____ the overload current the faster the circuit will open, but a smaller overload would take much longer to open the circuit.
(Multiple Choice)
4.8/5
(41)
Overload units utilize the motor load current to mimic the _______________ characteristics of the motor being protected.
(Short Answer)
4.8/5
(29)
Overload units are designed to help energize a motor that is building up excessive heat.
(True/False)
4.8/5
(36)
Electronic type of thermal overload units are adjustable for a range of motor load currents, and are set for the full load amperes (FLA) of the specific motor load.
(True/False)
4.7/5
(38)
The most common type of overload unit is the electronic overload unit.
(True/False)
4.8/5
(35)
What is the best way to assure adequate protection for an overload unit?
(Essay)
4.7/5
(36)
When the melting alloy is a solid, the shaft of the ratchet wheel is held from turning.
(True/False)
4.7/5
(33)
Electronic motor overload units ____ the motor differently than either the melting alloy or the bimetallic overload units.
(Multiple Choice)
4.7/5
(42)
The overload unit contacts are connected in parallel with the motor starter contactor unit control coil.
(True/False)
4.8/5
(35)
When the bimetallic strip is heated, the metal with the lower thermal expansion characteristic will become longer, and cause the metal strip to bend.
(True/False)
5.0/5
(34)
It is important to understand that each different type of overload protection method requires its own _______________.
(Short Answer)
4.8/5
(34)
Thermal overload units conduct the motor load current through heater elements.
(True/False)
4.9/5
(41)
The thermal overload unit of the motor starter is located below the ____ contractor.
(Multiple Choice)
4.9/5
(40)
The _______________ unit is operated by heat developed from the motor load current going through the overload heaters.
(Short Answer)
4.9/5
(40)
The three most common types of overload units are the melting alloy (eutectic), bimetallic, and _______________.
(Short Answer)
4.9/5
(43)