Exam 8: Overload Units

arrow
  • Select Tags
search iconSearch Question
  • Select Tags

Overload units are designed with an inverse time-delay function.

Free
(True/False)
4.8/5
(38)
Correct Answer:
Verified

True

The absolute best way to assure adequate motor protection is to consult the cover of the motor ____, the motor control center, or the manufacturers catalog at the time of installation.

Free
(Multiple Choice)
4.8/5
(34)
Correct Answer:
Verified

A

The eutectic alloy in the heater barrel element is a material that goes from a solid state to a liquid state without going through an intermediate ____ stage.

Free
(Multiple Choice)
4.8/5
(33)
Correct Answer:
Verified

C

Overload protection is designed with inverse time-delay trip characteristics.This means the ____ the overload current the faster the circuit will open, but a smaller overload would take much longer to open the circuit.

(Multiple Choice)
4.8/5
(41)

Overload units utilize the motor load current to mimic the _______________ characteristics of the motor being protected.

(Short Answer)
4.8/5
(29)

Overload units are designed to help energize a motor that is building up excessive heat.

(True/False)
4.8/5
(36)

Electronic type of thermal overload units are adjustable for a range of motor load currents, and are set for the full load amperes (FLA) of the specific motor load.

(True/False)
4.7/5
(38)

The most common type of overload unit is the electronic overload unit.

(True/False)
4.8/5
(35)

What is the best way to assure adequate protection for an overload unit?

(Essay)
4.7/5
(36)

When the melting alloy is a solid, the shaft of the ratchet wheel is held from turning.

(True/False)
4.7/5
(33)

Electronic motor overload units ____ the motor differently than either the melting alloy or the bimetallic overload units.

(Multiple Choice)
4.7/5
(42)

What are the three most common types of overload units?

(Essay)
4.8/5
(34)

The overload unit contacts are connected in parallel with the motor starter contactor unit control coil.

(True/False)
4.8/5
(35)

When the bimetallic strip is heated, the metal with the lower thermal expansion characteristic will become longer, and cause the metal strip to bend.

(True/False)
5.0/5
(34)

It is important to understand that each different type of overload protection method requires its own _______________.

(Short Answer)
4.8/5
(34)

Thermal overload units conduct the motor load current through heater elements.

(True/False)
4.9/5
(41)

The thermal overload unit of the motor starter is located below the ____ contractor.

(Multiple Choice)
4.9/5
(40)

A bimetallic strip is used as a(n) _______________ lever.

(Short Answer)
4.7/5
(46)

The _______________ unit is operated by heat developed from the motor load current going through the overload heaters.

(Short Answer)
4.9/5
(40)

The three most common types of overload units are the melting alloy (eutectic), bimetallic, and _______________.

(Short Answer)
4.9/5
(43)
close modal

Filters

  • Essay(0)
  • Multiple Choice(0)
  • Short Answer(0)
  • True False(0)
  • Matching(0)