Exam 6: Special Purpose Motor, Control Devices and Programmable Logic Controllers
Exam 1: Introduction to Industrial Control Systems, Discrete Control Input and Output Devices105 Questions
Exam 2: Solidstate Devices in Industrial Applications, Operational Amplifiers and Linear ICS79 Questions
Exam 3: SCRS, Triacs, Other Thryristors, Discrete Automation Sensors and Devices100 Questions
Exam 4: Analog Processes Control Devices, Sensors and Safety102 Questions
Exam 5: DC Motors, Control Circuits, AC Motors and Variable Speed Drives89 Questions
Exam 6: Special Purpose Motor, Control Devices and Programmable Logic Controllers125 Questions
Exam 7: Embedded Microcontrollers, Open and Closed Loop Process Control130 Questions
Exam 8: Industrial Robots, Automation Systems and Data Communication Between Intelligent Machines115 Questions
Select questions type
When the on -off transitions from each of the two tracks of an optical encoder are counted, the resolution is increased by a factor of eight.
Free
(True/False)
4.8/5
(38)
Correct Answer:
False
The best PLC language for developing the basic structure of the program is
Free
(Multiple Choice)
4.8/5
(32)
Correct Answer:
B
Detent torque is the maximum load -originating torque that the motor can stand without moving from its position with the stator energized.
Free
(True/False)
4.8/5
(31)
Correct Answer:
False
Relay ladder logic and ladder logic for a PLC program are similar because the output symbols and control logic are on a rung, but different because the PLC ladder never has field device switch contacts located in it.
(True/False)
4.7/5
(48)
The IEC 61131 ladder logic symbol library has only input contacts and output symbols available.
(True/False)
4.9/5
(38)
Which one of the following is not a part of the PLC scan cycle?
(Multiple Choice)
4.7/5
(41)
Examine on contacts look like NO contact symbols and must have NO contacts on the associated field device wired to the input pin for that address.
(True/False)
4.9/5
(41)
Which of the following is NOT a sequential function chart sequence?
(Multiple Choice)
4.8/5
(40)
Which of the following statements is NOT true during a PLC scan?
(Multiple Choice)
4.8/5
(39)
The DeviceNet module is used to communicate primarily with motor controllers.
(True/False)
4.7/5
(36)
Scan time is the time it takes for the PLC to read all input data and write that data into an input register.
(True/False)
4.8/5
(42)
Match the Allen Bradley SLC 500 register symbol with the register function.
-C5
(Multiple Choice)
4.8/5
(38)
In rack/slot addressing the slot location of the PLC processor is indicated in the address.
(True/False)
4.9/5
(31)
Comparitors in the SLC 500 PLC must always be used on the input or right side of the ladder rung.
(True/False)
4.9/5
(31)
The permanent magnetic DC motor acquires its magnetic field from a permanent magnetic and an electromagnetic.
(True/False)
4.9/5
(43)
Use the following ladder logic rung when matching the following answers.
-Output coil is active when

(Multiple Choice)
4.9/5
(49)
Showing 1 - 20 of 125
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)