When the on -off transitions from each of the two tracks of an optical encoder are counted, the resolution is increased by a factor of eight.

Free
(True/False)
4.8/5
(38)
Correct Answer:
Verified

False

The best PLC language for developing the basic structure of the program is

Free
(Multiple Choice)
4.8/5
(32)
Correct Answer:
Verified

B

Detent torque is the maximum load -originating torque that the motor can stand without moving from its position with the stator energized.

Free
(True/False)
4.8/5
(31)
Correct Answer:
Verified

False

The output symbol on a PLC ladder logic rung is active if

(Multiple Choice)
4.7/5
(26)

A conventional PM motor is also known as a wound rotor PM motor.

(True/False)
4.9/5
(35)

Relay ladder logic and ladder logic for a PLC program are similar because the output symbols and control logic are on a rung, but different because the PLC ladder never has field device switch contacts located in it.

(True/False)
4.7/5
(48)

The IEC 61131 ladder logic symbol library has only input contacts and output symbols available.

(True/False)
4.9/5
(38)

Which one of the following is not a part of the PLC scan cycle?

(Multiple Choice)
4.7/5
(41)

Examine on contacts look like NO contact symbols and must have NO contacts on the associated field device wired to the input pin for that address.

(True/False)
4.9/5
(41)

Which of the following is NOT a sequential function chart sequence?

(Multiple Choice)
4.8/5
(40)

Which of the following statements is NOT true during a PLC scan?

(Multiple Choice)
4.8/5
(39)

The DeviceNet module is used to communicate primarily with motor controllers.

(True/False)
4.7/5
(36)

Scan time is the time it takes for the PLC to read all input data and write that data into an input register.

(True/False)
4.8/5
(42)

Match the Allen Bradley SLC 500 register symbol with the register function. -C5

(Multiple Choice)
4.8/5
(38)

In rack/slot addressing the slot location of the PLC processor is indicated in the address.

(True/False)
4.9/5
(31)

Match the features to its motor . -Runs hot

(Multiple Choice)
4.8/5
(27)

Comparitors in the SLC 500 PLC must always be used on the input or right side of the ladder rung.

(True/False)
4.9/5
(31)

The permanent magnetic DC motor acquires its magnetic field from a permanent magnetic and an electromagnetic.

(True/False)
4.9/5
(43)

If the input address is I:4/10, then

(Multiple Choice)
4.8/5
(30)

Use the following ladder logic rung when matching the following answers. ‪ Use the following ladder logic rung when matching the following answers. ‪   -Output coil is active when -Output coil is active when

(Multiple Choice)
4.9/5
(49)