The formula for dose length product (DLP)is
Free
(Multiple Choice)
4.9/5
(38)
Correct Answer:
A
A pitch of 1 indicates that with each rotation of the tube
Free
(Multiple Choice)
4.9/5
(30)
Correct Answer:
C
Automatic tube current modulation is a method
Free
(Multiple Choice)
4.7/5
(35)
Correct Answer:
D
Which of the following measures mean absorbed dose in the scanned object volume,adjusted for weighted index and pitch in MSCT?
(Multiple Choice)
4.8/5
(31)
This shading artifact is due to the beam energy changing (and therefore the CT numbers)as the beam passes through the anatomy
(Multiple Choice)
4.9/5
(30)
The collimator that improves image contrast by limiting the amount of scatter radiation that reaches the detector is the
(Multiple Choice)
4.8/5
(29)
The DAS receives an electrical signal from the detector-photodiode.
(True/False)
4.9/5
(40)
The scintillation-type detector is commonly used in today's CT scanner.
(True/False)
4.8/5
(35)
How will a pixel with a CT number of -250 appear if the WW is 600 and the WL is -300?
(Multiple Choice)
4.8/5
(35)
The composite electrical signal based on transmission values is the
(Multiple Choice)
4.8/5
(27)
The high-frequency generator used in CT scanning has minimal voltage ripple,allowing
(Multiple Choice)
4.8/5
(27)
Which of the following is used to trigger a message when cumulative dose at a location,plus the dose for the next planned and confirmed scan(s),is likely to exceed a pre-programmed value?
(Multiple Choice)
4.8/5
(43)
Most modern CT scanners are based on _______________________ technology.
(Multiple Choice)
4.9/5
(33)
Because of the minimal amount of scatter radiation produced during a CT scan,there is no need to be concerned with the protection of others who must remain in the room during a CT scan.
(True/False)
4.8/5
(40)