Exam 10: Radiographic Exposure Technique
Exam 1: Introduction to the Imaging Sciences75 Questions
Exam 2: Structure of the Atom63 Questions
Exam 3: Electromagnetic and Particulate Radiation58 Questions
Exam 4: X-Ray Circuit147 Questions
Exam 5: The X-Ray Tube108 Questions
Exam 6: X-Ray Production68 Questions
Exam 7: X-Ray Interactions With Matter63 Questions
Exam 8: Image Production66 Questions
Exam 9: Image Characteristics161 Questions
Exam 10: Radiographic Exposure Technique163 Questions
Exam 11: Scatter Control80 Questions
Exam 12: Image Receptors167 Questions
Exam 13: Automatic Exposure Control60 Questions
Exam 14: Image Intensified Fluoroscopy100 Questions
Exam 15: Additional Equipment54 Questions
Exam 16: Computed Tomography125 Questions
Select questions type
If a film image has to be repeated because of a positioning error,what should be done if the density was just a little too much?
Free
(Multiple Choice)
4.8/5
(35)
Correct Answer:
D
Using excessive kVp with a digital IR results in:
Free
(Multiple Choice)
4.7/5
(41)
Correct Answer:
D
What mA should be selected to produce 32 mAs using a 0.04 exposure time?
(Multiple Choice)
4.9/5
(35)
If 400 mA @ 0.03 s produces a film image of a knee that is just a bit too light to see the bony structure,the exposure factors should be changed to:
(Multiple Choice)
5.0/5
(38)
If a film image appears dark,to produce a diagnostic image you may decide to:
(Multiple Choice)
4.8/5
(39)
If the intensity of radiation at 72 inches is 225 mR,what is the intensity if the SID is decreased to 40 inches?
(Multiple Choice)
4.9/5
(37)
Using a grid to reduce scatter radiation reaching the film-screen IR results in:
(Multiple Choice)
4.8/5
(42)
Exposure factors that include higher kVp and lower mAs are recommended for both film and digital imaging to reduce patient exposure.
(True/False)
4.8/5
(40)
A magnification of factor of 1 cannot be achieved with radiographic imaging.
(True/False)
4.7/5
(31)
The ________________ body habitus accounts for approximately 50% of the adult population.
(Multiple Choice)
4.9/5
(34)
Which of the following results in increased scatter radiation reaching the IR?
(Multiple Choice)
4.9/5
(37)
The optimal kVp for digital image receptors should be _________ than that for film-screen image receptors.
(Multiple Choice)
4.7/5
(36)
The relationship between kVp and the quantity of remnant radiation is known as the:
(Multiple Choice)
4.9/5
(37)
As the SID increases,the x-ray photons in the beam become less perpendicular to the object being imaged.
(True/False)
4.8/5
(42)
Which of the following is the correct formula to determine how mAs should be adjusted when different ratio grids are used?
(Multiple Choice)
4.8/5
(35)
Which of the following has an effect on how much mAs is used for a specific examination?
(Multiple Choice)
4.8/5
(40)
With digital imaging,if the image receptor is not exposed to enough radiation:
(Multiple Choice)
4.9/5
(36)
Assuming that all of these produce a similar amount of exit radiation,which of the following exposure factors minimize the radiation dose to the patient?
(Multiple Choice)
4.9/5
(38)
Showing 1 - 20 of 163
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)