Exam 11: Retrofit and Future Trends

arrow
  • Select Tags
search iconSearch Question
flashcardsStudy Flashcards
  • Select Tags

XH7 and XH9 desiccants are compatible with R-134a and R-12 refrigerants.

(True/False)
5.0/5
(34)

What questions should the technician ask the customer if there is a possibility that the refrigerant is contaminated?

(Essay)
4.7/5
(41)

R-744 systems require about half the refrigerant capacity of current R-134a systems.

(True/False)
4.7/5
(37)

The air conditioning system is purged of refrigerant if the manifold gauges show a vacuum.

(True/False)
4.8/5
(38)

Technician A says changing any part of an original design changes the performance of the equipment.Technician B says if an extra fan and motor are added,a relay should also be added.Who is correct?

(Multiple Choice)
4.8/5
(35)

The retro fit label's background color for R-134a refrigerant is:

(Multiple Choice)
4.9/5
(45)

What is the maximum capacity a recovery cylinder should be filled to at ambient temperatures.

(Short Answer)
4.8/5
(32)

All of the following statements about thermostatic expansion vales on retrofitted systems are true,EXCEPT:

(Multiple Choice)
4.8/5
(43)

Evacuation of an air conditioning system is being discussed.Technician A says one factor affecting the speed of evacuation is internal restrictions.Technician B says all of the oil is usually removed during evacuation.Who is correct?

(Multiple Choice)
4.9/5
(36)

Technician A says the purity of refrigerants has been set by SAE purity standards for both R-12 and R-134a.Technician B says refrigerant should test at least 98 percent pure when tested with a purity tester.Who is correct?

(Multiple Choice)
4.9/5
(35)

What does it mean if after 5 minutes,the vacuum pump cannot pull a reasonable vacuum on the refrigerant system?

(Short Answer)
4.7/5
(30)

Why would a R-744 refrigerant system work well on a fuel cell-powered vehicle?

(Essay)
4.9/5
(41)

During the retrofit process,when should service ports be changed from R-12 to R-134a access type?

(Essay)
4.8/5
(31)

R-12 with greater than 2 percent of R-134a is considered contaminated.

(True/False)
4.9/5
(38)

R-744 is an acceptable substitute for both R-12 and R-134a in a refrigerant system retrofit.

(True/False)
4.8/5
(35)

Technician A says that the shop that performed the A/C system retrofit must be identified on the retrofit label.Technician Bsays that the new refrigerant installed must be identified on the retrofit label.Who is correct?

(Multiple Choice)
4.8/5
(40)

During the charging process of a FOT cycling-clutch system,how can you override the system so the compressor will stay engaged and not cycle?

(Essay)
4.9/5
(21)

The R-744 system can serve as a source of heat for the passenger compartment through the use of an integrated heat pump.

(True/False)
4.8/5
(23)

Discuss the use of conversion service fittings for conversions of R-12 to R-134a refrigerant.

(Essay)
4.9/5
(37)

Give the general guidelines for determining whether a compressor should be replaced during retrofit.

(Essay)
4.7/5
(37)
Showing 21 - 40 of 45
close modal

Filters

  • Essay(0)
  • Multiple Choice(0)
  • Short Answer(0)
  • True False(0)