Exam 18: Bisecting Technique
Exam 1: Radiation History8 Questions
Exam 2: Radiation Physics32 Questions
Exam 3: Radiation Characteristics21 Questions
Exam 4: Radiation Biology32 Questions
Exam 5: Radiation Protection24 Questions
Exam 6: Dental X-Ray Equipment12 Questions
Exam 7: Dental X-Ray Film43 Questions
Exam 8: Dental X-Ray Image Characteristics23 Questions
Exam 9: Dental X-Ray Film Processing70 Questions
Exam 10: Quality Assurance in the Dental Office25 Questions
Exam 11: Dental Radiographs and the Dental Radiographer11 Questions
Exam 12: Patient Relations and the Dental Radiographer10 Questions
Exam 13: Patient Education and the Dental Radiographer17 Questions
Exam 14: Legal Issues and the Dental Radiographer16 Questions
Exam 15: Infection Control and the Dental Radiographer24 Questions
Exam 16: Introduction to Radiographic Examinations11 Questions
Exam 17: Paralleling Technique26 Questions
Exam 18: Bisecting Technique32 Questions
Exam 19: Bite-Wing Technique17 Questions
Exam 20: Exposure and Technique Errors24 Questions
Exam 21: Occlusal and Localization Techniques18 Questions
Exam 22: Panoramic Imaging31 Questions
Exam 23: Extraoral Imaging28 Questions
Exam 24: Imaging of Patients With Special Needs18 Questions
Exam 25: Digital Imaging21 Questions
Exam 26: Three-Dimensional Digital Imaging26 Questions
Exam 27: Normal Anatomy: Intraoral Images62 Questions
Exam 28: Film Mounting and Viewing17 Questions
Exam 29: Normal Anatomy: Panoramic Images29 Questions
Exam 30: Introduction to Image Interpretation6 Questions
Exam 31: Descriptive Terminology18 Questions
Exam 32: Identification of Restorations, Dental Materials, and Foreign Objects15 Questions
Exam 33: Interpretation of Dental Caries12 Questions
Exam 34: Interpretation of Periodontal Disease12 Questions
Exam 35: Interpretation of Trauma and Pulpal and Periapical Lesions20 Questions
Select questions type
When the bisecting technique is used, the central ray is directed at 90 degrees to the:
Free
(Multiple Choice)
4.8/5
(44)
Correct Answer:
D
According to the text, the disadvantages of the bisecting technique outweigh the advantages. Therefore, the paralleling technique is preferred over the bisecting technique for exposure of periapical films and should be used whenever possible.
Free
(Multiple Choice)
4.8/5
(34)
Correct Answer:
A
When the bisecting technique is used, foreshortening will occur if the central ray is directed perpendicular to the:
Free
(Multiple Choice)
4.8/5
(31)
Correct Answer:
A
With the bisecting technique, the recommended vertical angulation range for maxillary canines is ____ degrees.
(Multiple Choice)
4.9/5
(45)
Film should be placed approximately ____ inch beyond the incisal or occlusal surfaces when using the bisecting technique.
(Multiple Choice)
4.9/5
(34)
With the ____ technique, the vertical angulation is determined by the imaginary bisector; the central ray is directed perpendicular to the imaginary bisector.
(Multiple Choice)
4.9/5
(27)
With the finger-holding method, which of the following would be used to hold the maxillary right molar film?
(Multiple Choice)
4.8/5
(28)
With the bisecting technique, the recommended vertical angulation range for mandibular molars is ____ degrees.
(Multiple Choice)
4.8/5
(39)
According to the recommended posterior periapical exposure sequence for the bisecting technique, the second posterior quadrant exposed should be the:
(Multiple Choice)
4.8/5
(36)
Horizontal angulation refers to the placement of the position-indicating device (PID) in a(n) ____ plane. Vertical angulation refers to the positioning of the PID in a(n) ____ plane.
(Multiple Choice)
4.8/5
(29)
Which of the following commercially available film holders are recommended for use with either the paralleling or the bisecting technique?
1) Rinn XCP instruments
2) Rinn BAI instruments
3) Precision film holder
4) Stabe bite-block
5) EEZEE-Grip film holder
(Multiple Choice)
4.8/5
(34)
The primary disadvantage of the bisecting technique when contrasted with the paralleling technique is:
(Multiple Choice)
4.8/5
(33)
The primary benefit of using film holders with the bisecting technique is:
(Multiple Choice)
4.9/5
(34)
Which size film is traditionally used with the bisecting technique?
(Multiple Choice)
4.8/5
(35)
When Rinn BAI instruments are used, "BAI" refers to which of the following?
(Multiple Choice)
4.9/5
(31)
The recommended anterior periapical exposure sequence for the bisecting technique starts with the:
(Multiple Choice)
4.8/5
(35)
For the maxillary premolar exposure, the front edge of the film should be aligned with the midline of the maxillary:
(Multiple Choice)
4.9/5
(32)
With the bite-wing technique, the vertical angulation is predetermined; the central ray is directed at ____ degrees to the occlusal plane.
(Multiple Choice)
4.9/5
(35)
With size 2 film, a total of ____ anterior film placements are used in the bisecting technique.
(Multiple Choice)
4.7/5
(49)
For the mandibular molar exposure, the front edge of the film should be aligned with the midline of the:
(Multiple Choice)
4.8/5
(34)
Showing 1 - 20 of 32
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)