Deck 19: Specific Equipment

Full screen (f)
exit full mode
Question
Individual office furnishings of the freestanding type, or groups of individual office furnishings that are electrically connected, are mechanically contiguous, and do not exceed 30 ft (9.0 m) when assembled, shall be permitted to connect to the building's electrical system by means of a ____.

A) single flexible cord and plug
B) rigid raceway
C) surge protector and concealed wiring
D) dual flexible cable and panel board
Use Space or
up arrow
down arrow
to flip the card.
Question
Flexible metal conduit, ____ metal conduit, liquidtight flexible nonmetallic conduit, and flexible cords and cables are permitted wiring methods on the counterweight assembly and on the car assembly in elevators.

A) rigid sealed
B) flexible hybrid
C) liquidtight flexible
D) liquidtight rigid
Question
A luminaire intended for installation in a pool or fountain structure's forming shell, where completely surrounded by water, is referred to as ____.

A) a wet niche luminaire
B) aquatic luminaire
C) forming shell
D) packaged source
Question
Electric signs and outline lighting systems shall be marked with the manufacturer's name, trademark or other identification, ____, and current rating.

A) input voltage
B) output wattage
C) potential lumens
D) average load
Question
Circuit voltage of heating/air-conditioning equipment branch circuits located on the elevator car shall not exceed ____ volts.

A) 500
B) 600
C) 800
D) 1000
Question
Article 647 covers the installation and wiring of sensitive electronic equipment that is connected to a separately derived system operating at ____ volts line-to-line and 60 volts to ground.

A) 100
B) 112
C) 120
D) 180
Question
Neon tubing secondary conductor(s) shall be supported within ____ in.(150 mm) of the electrode connection.

A) 4
B) 6
C) 12
D) 18
Question
A separately derived ____ with 60 volts on each of two ungrounded conductors to an equipment grounding conductor can be used to reduce objectionable noise in sensitive electronic equipment locations.

A) 110-volt, single-phase, 3-wire system
B) 115-volt, single-phase, 3-wire system
C) 120-volt, single-phase, 3-wire system
D) 125-volt, single-phase, 3-wire system
Question
Electric signs and outline lighting system equipment in wet locations, unless of the listed watertight type, shall be weatherproof and, if necessary, have ____ in accordance with 600.9(D)(1) through (3).

A) surge protection
B) lightning protection
C) a front-mounted disconnect
D) drain holes
Question
The minimum conductor size for traveling cables that feed lighting circuits is ____ AWG copper.

A) 14
B) 16
C) 18
D) 20
Question
An electric vehicle supply equipment's coupling means shall be stored or located at a height of not less than ____ above the floor level for indoor locations and 24 in.(600 mm) above the grade level for outdoor locations.

A) 12 in.(305 mm)
B) 14 in.(357 mm)
C) 18 in.(450 mm)
D) 24 in.(610 mm)
Question
Neon tubing's length and design shall not cause a continuous overcurrent beyond the capacity of the transformer or ____.

A) surge protection
B) disconnecting means
C) electronic power supply
D) branch circuit
Question
Conductors in pipe organs shall have ____ insulation.

A) standard polymer
B) thermoplastic or thermosetting
C) thermoelastic or thermo-molded
D) hybrid plastic/polymer
Question
Branch circuits and feeders in a separately derived 60-volts to ground system shall be provided with a means to ____.

A) prevent current surges
B) simultaneously disconnect all ungrounded conductors
C) protect from lightning discharges
D) permit service access
Question
Equipment used to combine and level-match a multiplicity of electronic signals, as from microphones, electronic instruments, and recorded audio, is referred to as a(n) ____.

A) panel board
B) mixer
C) audio swapper
D) signal transformer
Question
DC power shall be supplied by a listed dc power supply with a maximum output of ____ volts.

A) 10
B) 20
C) 25
D) 30
Question
A pipe organ should use a minimum of ____ AWG conductors for electronic signal circuits, and at least 26 AWG for electromagnetic valve supply.

A) 24
B) 26
C) 28
D) 30
Question
FMC, LFMC, or LFNC of _____ nominal trade size or larger and no longer than 6 ft (1.8 m) can be installed between control panels and machine motors, machine brakes, motor-generator sets, disconnecting means, and pumping unit motors and valves.

A) 1/4
B) 3/8
C) 5/8
D) 3/4
Question
Each hoistway elevator pit shall have at least one ____-volt, single phase, 15- or 20-ampere duplex receptacle

A) 100
B) 120
C) 125
D) 140
Question
All ____ receptacle outlets used in technical applications shall be GFCI protected.

A) 15- and 20-ampere
B) 15- and 25-ampere
C) 15- and 30-ampere
D) 20- and 30-ampere
Question
Unencapsulated structural reinforcing steel in pools shall be ____.

A) bonded together by steel tie wires or the equivalent
B) grounded via rigid wire cables to an earth ground
C) bonded using equipotential bonding
D) encased in corrosion-resistant materials
Question
Equipotential bonding required by 680.26 shall be installed to reduce ____ in the pool area.

A) power surges
B) shorting
C) load
D) voltage gradients
Question
A junction box for an underwater application shall be comprised of ____, brass, suitable plastic, or other approved corrosion-resistant material.

A) stainless steel
B) aluminum
C) tin
D) copper
Question
Unit heaters shall not be mounted over the pool or within the area extending ____ horizontally from the inside walls of a pool.

A) 5 ft (1.5 m)
B) 6 ft (1.8 m)
C) 8 ft (2.4 m)
D) 9 ft (2.7 m)
Question
Where a permanently installed pool is installed, no fewer than one 125-volt 15- or 20-ampere receptacle on a general-purpose branch circuit shall be located a minimum of ____, but no more than 20 ft (6.0 m), from the pool's inside wall.

A) 5 ft (1.52 m)
B) 6 ft (1.83 m)
C) 8 ft (2.44 m)
D) 12 ft (3.66 m)
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/25
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 19: Specific Equipment
1
Individual office furnishings of the freestanding type, or groups of individual office furnishings that are electrically connected, are mechanically contiguous, and do not exceed 30 ft (9.0 m) when assembled, shall be permitted to connect to the building's electrical system by means of a ____.

A) single flexible cord and plug
B) rigid raceway
C) surge protector and concealed wiring
D) dual flexible cable and panel board
A
2
Flexible metal conduit, ____ metal conduit, liquidtight flexible nonmetallic conduit, and flexible cords and cables are permitted wiring methods on the counterweight assembly and on the car assembly in elevators.

A) rigid sealed
B) flexible hybrid
C) liquidtight flexible
D) liquidtight rigid
C
3
A luminaire intended for installation in a pool or fountain structure's forming shell, where completely surrounded by water, is referred to as ____.

A) a wet niche luminaire
B) aquatic luminaire
C) forming shell
D) packaged source
A
4
Electric signs and outline lighting systems shall be marked with the manufacturer's name, trademark or other identification, ____, and current rating.

A) input voltage
B) output wattage
C) potential lumens
D) average load
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
5
Circuit voltage of heating/air-conditioning equipment branch circuits located on the elevator car shall not exceed ____ volts.

A) 500
B) 600
C) 800
D) 1000
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
6
Article 647 covers the installation and wiring of sensitive electronic equipment that is connected to a separately derived system operating at ____ volts line-to-line and 60 volts to ground.

A) 100
B) 112
C) 120
D) 180
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
7
Neon tubing secondary conductor(s) shall be supported within ____ in.(150 mm) of the electrode connection.

A) 4
B) 6
C) 12
D) 18
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
8
A separately derived ____ with 60 volts on each of two ungrounded conductors to an equipment grounding conductor can be used to reduce objectionable noise in sensitive electronic equipment locations.

A) 110-volt, single-phase, 3-wire system
B) 115-volt, single-phase, 3-wire system
C) 120-volt, single-phase, 3-wire system
D) 125-volt, single-phase, 3-wire system
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
9
Electric signs and outline lighting system equipment in wet locations, unless of the listed watertight type, shall be weatherproof and, if necessary, have ____ in accordance with 600.9(D)(1) through (3).

A) surge protection
B) lightning protection
C) a front-mounted disconnect
D) drain holes
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
10
The minimum conductor size for traveling cables that feed lighting circuits is ____ AWG copper.

A) 14
B) 16
C) 18
D) 20
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
11
An electric vehicle supply equipment's coupling means shall be stored or located at a height of not less than ____ above the floor level for indoor locations and 24 in.(600 mm) above the grade level for outdoor locations.

A) 12 in.(305 mm)
B) 14 in.(357 mm)
C) 18 in.(450 mm)
D) 24 in.(610 mm)
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
12
Neon tubing's length and design shall not cause a continuous overcurrent beyond the capacity of the transformer or ____.

A) surge protection
B) disconnecting means
C) electronic power supply
D) branch circuit
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
13
Conductors in pipe organs shall have ____ insulation.

A) standard polymer
B) thermoplastic or thermosetting
C) thermoelastic or thermo-molded
D) hybrid plastic/polymer
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
14
Branch circuits and feeders in a separately derived 60-volts to ground system shall be provided with a means to ____.

A) prevent current surges
B) simultaneously disconnect all ungrounded conductors
C) protect from lightning discharges
D) permit service access
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
15
Equipment used to combine and level-match a multiplicity of electronic signals, as from microphones, electronic instruments, and recorded audio, is referred to as a(n) ____.

A) panel board
B) mixer
C) audio swapper
D) signal transformer
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
16
DC power shall be supplied by a listed dc power supply with a maximum output of ____ volts.

A) 10
B) 20
C) 25
D) 30
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
17
A pipe organ should use a minimum of ____ AWG conductors for electronic signal circuits, and at least 26 AWG for electromagnetic valve supply.

A) 24
B) 26
C) 28
D) 30
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
18
FMC, LFMC, or LFNC of _____ nominal trade size or larger and no longer than 6 ft (1.8 m) can be installed between control panels and machine motors, machine brakes, motor-generator sets, disconnecting means, and pumping unit motors and valves.

A) 1/4
B) 3/8
C) 5/8
D) 3/4
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
19
Each hoistway elevator pit shall have at least one ____-volt, single phase, 15- or 20-ampere duplex receptacle

A) 100
B) 120
C) 125
D) 140
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
20
All ____ receptacle outlets used in technical applications shall be GFCI protected.

A) 15- and 20-ampere
B) 15- and 25-ampere
C) 15- and 30-ampere
D) 20- and 30-ampere
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
21
Unencapsulated structural reinforcing steel in pools shall be ____.

A) bonded together by steel tie wires or the equivalent
B) grounded via rigid wire cables to an earth ground
C) bonded using equipotential bonding
D) encased in corrosion-resistant materials
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
22
Equipotential bonding required by 680.26 shall be installed to reduce ____ in the pool area.

A) power surges
B) shorting
C) load
D) voltage gradients
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
23
A junction box for an underwater application shall be comprised of ____, brass, suitable plastic, or other approved corrosion-resistant material.

A) stainless steel
B) aluminum
C) tin
D) copper
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
24
Unit heaters shall not be mounted over the pool or within the area extending ____ horizontally from the inside walls of a pool.

A) 5 ft (1.5 m)
B) 6 ft (1.8 m)
C) 8 ft (2.4 m)
D) 9 ft (2.7 m)
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
25
Where a permanently installed pool is installed, no fewer than one 125-volt 15- or 20-ampere receptacle on a general-purpose branch circuit shall be located a minimum of ____, but no more than 20 ft (6.0 m), from the pool's inside wall.

A) 5 ft (1.52 m)
B) 6 ft (1.83 m)
C) 8 ft (2.44 m)
D) 12 ft (3.66 m)
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck