Exam 19: Specific Equipment
Exam 1: Introduction to the National Electrical Code13 Questions
Exam 2: Definitions25 Questions
Exam 3: Boxes and Enclosures25 Questions
Exam 4: Cables17 Questions
Exam 5: Raceways and Conductors26 Questions
Exam 6: General Provisions25 Questions
Exam 7: Specific Provisions25 Questions
Exam 8: Load Calculations25 Questions
Exam 9: Services and Electrical Equipment27 Questions
Exam 10: Comprehensive Provisions25 Questions
Exam 11: Load Calculations14 Questions
Exam 12: General Provisions25 Questions
Exam 13: Nondwelling Load Calculations17 Questions
Exam 14: Services Feeders and Equipment25 Questions
Exam 15: Hazardous Classified Locations25 Questions
Exam 16: Health Care25 Questions
Exam 17: Industrial Locations25 Questions
Exam 18: Special Occupancies26 Questions
Exam 19: Specific Equipment25 Questions
Select questions type
Unit heaters shall not be mounted over the pool or within the area extending ____ horizontally from the inside walls of a pool.
Free
(Multiple Choice)
4.9/5
(43)
Correct Answer:
A
DC power shall be supplied by a listed dc power supply with a maximum output of ____ volts.
Free
(Multiple Choice)
4.8/5
(45)
Correct Answer:
D
Circuit voltage of heating/air-conditioning equipment branch circuits located on the elevator car shall not exceed ____ volts.
Free
(Multiple Choice)
4.9/5
(32)
Correct Answer:
D
Neon tubing secondary conductor(s) shall be supported within ____ in.(150 mm) of the electrode connection.
(Multiple Choice)
4.9/5
(31)
An electric vehicle supply equipment's coupling means shall be stored or located at a height of not less than ____ above the floor level for indoor locations and 24 in.(600 mm) above the grade level for outdoor locations.
(Multiple Choice)
4.8/5
(38)
A pipe organ should use a minimum of ____ AWG conductors for electronic signal circuits, and at least 26 AWG for electromagnetic valve supply.
(Multiple Choice)
5.0/5
(35)
Equipment used to combine and level-match a multiplicity of electronic signals, as from microphones, electronic instruments, and recorded audio, is referred to as a(n) ____.
(Multiple Choice)
4.8/5
(35)
Equipotential bonding required by 680.26 shall be installed to reduce ____ in the pool area.
(Multiple Choice)
4.9/5
(42)
A junction box for an underwater application shall be comprised of ____, brass, suitable plastic, or other approved corrosion-resistant material.
(Multiple Choice)
4.9/5
(33)
The minimum conductor size for traveling cables that feed lighting circuits is ____ AWG copper.
(Multiple Choice)
4.8/5
(42)
A luminaire intended for installation in a pool or fountain structure's forming shell, where completely surrounded by water, is referred to as ____.
(Multiple Choice)
4.9/5
(32)
Unencapsulated structural reinforcing steel in pools shall be ____.
(Multiple Choice)
4.9/5
(44)
FMC, LFMC, or LFNC of _____ nominal trade size or larger and no longer than 6 ft (1.8 m) can be installed between control panels and machine motors, machine brakes, motor-generator sets, disconnecting means, and pumping unit motors and valves.
(Multiple Choice)
4.8/5
(36)
Flexible metal conduit, ____ metal conduit, liquidtight flexible nonmetallic conduit, and flexible cords and cables are permitted wiring methods on the counterweight assembly and on the car assembly in elevators.
(Multiple Choice)
4.9/5
(41)
Article 647 covers the installation and wiring of sensitive electronic equipment that is connected to a separately derived system operating at ____ volts line-to-line and 60 volts to ground.
(Multiple Choice)
4.8/5
(39)
Each hoistway elevator pit shall have at least one ____-volt, single phase, 15- or 20-ampere duplex receptacle
(Multiple Choice)
4.9/5
(36)
Electric signs and outline lighting system equipment in wet locations, unless of the listed watertight type, shall be weatherproof and, if necessary, have ____ in accordance with 600.9(D)(1) through (3).
(Multiple Choice)
4.8/5
(38)
Electric signs and outline lighting systems shall be marked with the manufacturer's name, trademark or other identification, ____, and current rating.
(Multiple Choice)
4.8/5
(42)
Branch circuits and feeders in a separately derived 60-volts to ground system shall be provided with a means to ____.
(Multiple Choice)
5.0/5
(37)
Showing 1 - 20 of 25
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)