Deck 5: Raceways and Conductors

Full screen (f)
exit full mode
Question
Liquidtight flexible metal conduit (LFMC) is a raceway of circular cross section having a(n) ____ over an inner flexible metal core.

A) outer liquidtight, nonmetallic, sunlight-resistant jacket
B) inflexible PVC coating
C) immersible (water tight) surface
D) sunlight-resistant, rigid, metallic outer jacket
Use Space or
up arrow
down arrow
to flip the card.
Question
Raceways installed within drop ceilings must ____.

A) be grounded internally to support wires
B) have adequate ventilation on all sides
C) have secure support provided by the support wires and associated fittings
D) be connected directly to a junction box
Question
Electric metal tubing (EMT) provides protection from ____.

A) all but severe physical damage
B) inadvertent grounding
C) water damage
D) lightening
Question
____ in the ends of larger conduits (2 to 6 in.) can prevent conduit collapses or other deformities.

A) Mounting supports
B) Mounting threaded ends
C) Installing elbows
D) Installing PVC plugs
Question
Electrical metallic tubing must not be ____.

A) colored
B) threaded
C) bent
D) placed in drywall
Question
A group of conductors that fit into one conduit may not fit into another type because the ____ of different types of conduit vary.

A) interfaces
B) spacing requirements
C) internal diameters
D) carrying capacity
Question
Article 100 defines raceway as a(n) ____designed expressly for holding wires, cables, or busbars.

A) bracketed suspension system
B) enclosed channel of metallic (or nonmetallic) materials
C) polymer-based vertical conduit
D) metallic duct
Question
NEC identifies ____ types of rigid PVC conduit.

A) two
B) three
C) five
D) ten
Question
Flexible metal conduit (FMC) is a raceway of circular cross section made of ____.

A) PVC laminated steel
B) helically wound, formed, and interlocked metal strips
C) concentrically wound aluminum alloy
D) interlocking metal and PVC conglomerate
Question
Contact of dissimilar metals (except for the combination of aluminum and steel) should be avoided wherever possible to lessen the potential for ____.

A) galvanic action
B) inadvertent shorting
C) structural weakening
D) static charging
Question
The minimum approved electrical trade size for EMT is ____ inches.

A) .15
B) .25
C) .5
D) .75
Question
The equivalent of ____ is the maximum allowed between pull points.

A) one quarter bends (90° total)
B) two half bends (180° total)
C) three quarter bends (270° total)
D) four quarter bends (360° total)
Question
The definition for intermediate metal conduit (IMC) and rigid metal conduit (RMC) is ____.

A) listed by the UL
B) determined locally
C) essentially the same
D) explained in terms of differing diameters
Question
PVC bends must be made so that the conduit remains undamaged and the internal diameter of the conduit is ____.

A) not reduced
B) reduced by no more than one third
C) reduced by no more than one half
D) reduced by no more than two thirds
Question
Grounding conductors are required for circuits over ____ amperes.

A) 10
B) 20
C) 30
D) 40
Question
Surface nonmetallic raceways and their fittings must be designed so that sections can be mechanically coupled together and installed without subjecting the wires to ____.

A) bending
B) abrasion
C) compression
D) tension
Question
Rigid metal conduit (RMC) is a threadable raceway of ____ designed for the physical protection and routing of conductors and cables.

A) an incompressible material
B) circular cross section
C) galvanized steel
D) various bending radii
Question
Raceway fill calculations are a prerequisite in ____ needed for particular circuits.

A) circuit loads
B) material requirements
C) schematic requirements
D) determining the size of raceway
Question
All cut ends of IMC and RMC must be ____.

A) anchored in a junction box
B) welded
C) color coded
D) reamed
Question
Bends must be made so that the conduit or tubing remains undamaged with its internal diameter ____.

A) diminished by no more than a tenth
B) diminished by no more than half
C) diminished by no more than a third
D) basically undiminished
Question
Half-round and flat-top raceways not over 4 inches in width must be covered by ____ or more of concrete (or wood).

A) .25 inches
B) .5 inches
C) .75 inches
D) one inch
Question
Underfloor raceway dead ends must be ____.

A) open
B) accessible
C) closed
D) non-accessible
Question
Splices and taps are permitted within surface metal raceway having a removable cover that ____.

A) is accessible at another junction
B) contains a trap facility
C) contains a branch to a junction box
D) remains accessible after installation
Question
A header is a transverse raceway ____.

A) that forms a continuous, unbroken conductor connecting individual outlets
B) in a cellular metal floor, that may be approved as enclosures for electric conductors
C) within rigid tubing enclosed in tubular space whose axis is parallel to the axis of a metal floor member
D) for electric conductors, providing access to predetermined cells of a cellular metal floor
Question
Wireways are ____ housing and protecting electric wires (and cables).

A) conductors for signaling circuits between a motor
B) troughs with hinged or removable covers for
C) ceiling fixtures connecting to luminaires or
D) current carrying junction boxes
Question
A multiconductor cable, optical fiber cable, or flexible cords of two or more conductors is treated as ____ for percentage conduit fill area calculations.

A) two conductors
B) three conductors
C) a single conductor
D) a neutral node
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/26
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 5: Raceways and Conductors
1
Liquidtight flexible metal conduit (LFMC) is a raceway of circular cross section having a(n) ____ over an inner flexible metal core.

A) outer liquidtight, nonmetallic, sunlight-resistant jacket
B) inflexible PVC coating
C) immersible (water tight) surface
D) sunlight-resistant, rigid, metallic outer jacket
A
2
Raceways installed within drop ceilings must ____.

A) be grounded internally to support wires
B) have adequate ventilation on all sides
C) have secure support provided by the support wires and associated fittings
D) be connected directly to a junction box
C
3
Electric metal tubing (EMT) provides protection from ____.

A) all but severe physical damage
B) inadvertent grounding
C) water damage
D) lightening
A
4
____ in the ends of larger conduits (2 to 6 in.) can prevent conduit collapses or other deformities.

A) Mounting supports
B) Mounting threaded ends
C) Installing elbows
D) Installing PVC plugs
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
5
Electrical metallic tubing must not be ____.

A) colored
B) threaded
C) bent
D) placed in drywall
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
6
A group of conductors that fit into one conduit may not fit into another type because the ____ of different types of conduit vary.

A) interfaces
B) spacing requirements
C) internal diameters
D) carrying capacity
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
7
Article 100 defines raceway as a(n) ____designed expressly for holding wires, cables, or busbars.

A) bracketed suspension system
B) enclosed channel of metallic (or nonmetallic) materials
C) polymer-based vertical conduit
D) metallic duct
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
8
NEC identifies ____ types of rigid PVC conduit.

A) two
B) three
C) five
D) ten
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
9
Flexible metal conduit (FMC) is a raceway of circular cross section made of ____.

A) PVC laminated steel
B) helically wound, formed, and interlocked metal strips
C) concentrically wound aluminum alloy
D) interlocking metal and PVC conglomerate
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
10
Contact of dissimilar metals (except for the combination of aluminum and steel) should be avoided wherever possible to lessen the potential for ____.

A) galvanic action
B) inadvertent shorting
C) structural weakening
D) static charging
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
11
The minimum approved electrical trade size for EMT is ____ inches.

A) .15
B) .25
C) .5
D) .75
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
12
The equivalent of ____ is the maximum allowed between pull points.

A) one quarter bends (90° total)
B) two half bends (180° total)
C) three quarter bends (270° total)
D) four quarter bends (360° total)
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
13
The definition for intermediate metal conduit (IMC) and rigid metal conduit (RMC) is ____.

A) listed by the UL
B) determined locally
C) essentially the same
D) explained in terms of differing diameters
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
14
PVC bends must be made so that the conduit remains undamaged and the internal diameter of the conduit is ____.

A) not reduced
B) reduced by no more than one third
C) reduced by no more than one half
D) reduced by no more than two thirds
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
15
Grounding conductors are required for circuits over ____ amperes.

A) 10
B) 20
C) 30
D) 40
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
16
Surface nonmetallic raceways and their fittings must be designed so that sections can be mechanically coupled together and installed without subjecting the wires to ____.

A) bending
B) abrasion
C) compression
D) tension
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
17
Rigid metal conduit (RMC) is a threadable raceway of ____ designed for the physical protection and routing of conductors and cables.

A) an incompressible material
B) circular cross section
C) galvanized steel
D) various bending radii
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
18
Raceway fill calculations are a prerequisite in ____ needed for particular circuits.

A) circuit loads
B) material requirements
C) schematic requirements
D) determining the size of raceway
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
19
All cut ends of IMC and RMC must be ____.

A) anchored in a junction box
B) welded
C) color coded
D) reamed
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
20
Bends must be made so that the conduit or tubing remains undamaged with its internal diameter ____.

A) diminished by no more than a tenth
B) diminished by no more than half
C) diminished by no more than a third
D) basically undiminished
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
21
Half-round and flat-top raceways not over 4 inches in width must be covered by ____ or more of concrete (or wood).

A) .25 inches
B) .5 inches
C) .75 inches
D) one inch
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
22
Underfloor raceway dead ends must be ____.

A) open
B) accessible
C) closed
D) non-accessible
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
23
Splices and taps are permitted within surface metal raceway having a removable cover that ____.

A) is accessible at another junction
B) contains a trap facility
C) contains a branch to a junction box
D) remains accessible after installation
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
24
A header is a transverse raceway ____.

A) that forms a continuous, unbroken conductor connecting individual outlets
B) in a cellular metal floor, that may be approved as enclosures for electric conductors
C) within rigid tubing enclosed in tubular space whose axis is parallel to the axis of a metal floor member
D) for electric conductors, providing access to predetermined cells of a cellular metal floor
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
25
Wireways are ____ housing and protecting electric wires (and cables).

A) conductors for signaling circuits between a motor
B) troughs with hinged or removable covers for
C) ceiling fixtures connecting to luminaires or
D) current carrying junction boxes
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
26
A multiconductor cable, optical fiber cable, or flexible cords of two or more conductors is treated as ____ for percentage conduit fill area calculations.

A) two conductors
B) three conductors
C) a single conductor
D) a neutral node
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 26 flashcards in this deck.