Exam 5: Raceways and Conductors
Exam 1: Introduction to the National Electrical Code13 Questions
Exam 2: Definitions25 Questions
Exam 3: Boxes and Enclosures25 Questions
Exam 4: Cables17 Questions
Exam 5: Raceways and Conductors26 Questions
Exam 6: General Provisions25 Questions
Exam 7: Specific Provisions25 Questions
Exam 8: Load Calculations25 Questions
Exam 9: Services and Electrical Equipment27 Questions
Exam 10: Comprehensive Provisions25 Questions
Exam 11: Load Calculations14 Questions
Exam 12: General Provisions25 Questions
Exam 13: Nondwelling Load Calculations19 Questions
Exam 14: Services, Feeders, and Equipment25 Questions
Exam 15: Hazardous Classified Locations25 Questions
Exam 16: Health Care25 Questions
Exam 17: Industrial Locations25 Questions
Exam 18: Special Occupancies25 Questions
Exam 19: Specific Equipment25 Questions
Select questions type
Flexible metal conduit (FMC) is a raceway of circular cross section made of ____.
Free
(Multiple Choice)
4.9/5
(36)
Correct Answer:
B
Grounding conductors are required for circuits over ____ amperes.
Free
(Multiple Choice)
4.9/5
(38)
Correct Answer:
B
NEC identifies ____ types of rigid PVC conduit.
Free
(Multiple Choice)
4.8/5
(41)
Correct Answer:
C
Bends must be made so that the conduit or tubing remains undamaged with its internal diameter ____.
(Multiple Choice)
4.8/5
(39)
Liquidtight flexible metal conduit (LFMC) is a raceway of circular cross section having a(n) ____ over an inner flexible metal core.
(Multiple Choice)
5.0/5
(31)
The equivalent of ____ is the maximum allowed between pull points.
(Multiple Choice)
4.7/5
(27)
The minimum approved electrical trade size for EMT is ____ inches.
(Multiple Choice)
4.8/5
(33)
Surface nonmetallic raceways and their fittings must be designed so that sections can be mechanically coupled together and installed without subjecting the wires to ____.
(Multiple Choice)
4.8/5
(35)
Half-round and flat-top raceways not over 4 inches in width must be covered by ____ or more of concrete (or wood).
(Multiple Choice)
4.7/5
(37)
Contact of dissimilar metals (except for the combination of aluminum and steel) should be avoided wherever possible to lessen the potential for ____.
(Multiple Choice)
4.8/5
(39)
Rigid metal conduit (RMC) is a threadable raceway of ____ designed for the physical protection and routing of conductors and cables.
(Multiple Choice)
4.8/5
(33)
Wireways are ____ housing and protecting electric wires (and cables).
(Multiple Choice)
4.9/5
(40)
A group of conductors that fit into one conduit may not fit into another type because the ____ of different types of conduit vary.
(Multiple Choice)
4.8/5
(35)
Article 100 defines raceway as a(n) ____designed expressly for holding wires, cables, or busbars.
(Multiple Choice)
4.9/5
(29)
PVC bends must be made so that the conduit remains undamaged and the internal diameter of the conduit is ____.
(Multiple Choice)
4.8/5
(33)
Splices and taps are permitted within surface metal raceway having a removable cover that ____.
(Multiple Choice)
4.7/5
(31)