Deck 32: Exposure Systems and Charts
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/39
Play
Full screen (f)
Deck 32: Exposure Systems and Charts
1
When viewing phantom images, professionals are not asked to select the
A)single best image.
B)images outside acceptance limits.
C)images within acceptance limits.
D)all of the above
A)single best image.
B)images outside acceptance limits.
C)images within acceptance limits.
D)all of the above
single best image.
2
Technique systems function best when a single variable is permitted to vary.
True
3
Most x-ray generators permit finer adjustment of kVp stations than of time or mA settings.
True
4
Many computerized exposure control systems utilize anatomically based programming.
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
5
Technique systems function best when a
A)large number of variables can be held constant.
B)single factor is permitted to vary.
C)method of consistency is used to produce a quality image.
D)all of the above
A)large number of variables can be held constant.
B)single factor is permitted to vary.
C)method of consistency is used to produce a quality image.
D)all of the above
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
6
Fixed kVp systems
A)produce more scatter radiation than other systems.
B)shorten exposure latitude.
C)increase x-ray tube wear.
D)are very popular because of the low contrast images.
A)produce more scatter radiation than other systems.
B)shorten exposure latitude.
C)increase x-ray tube wear.
D)are very popular because of the low contrast images.
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
7
The device used to measure part thickness is called a
A)collimator.
B)caliper.
C)protractor.
D)goniometer.
A)collimator.
B)caliper.
C)protractor.
D)goniometer.
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
8
When a new piece of imaging equipment is added to the imaging chain, technique charts must be re-established.
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
9
Fixed kVp systems produce more scatter radiation than other systems.
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
10
Fixed kVp systems tend to decrease patient dose.
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
11
Fixed kVp systems
A)increase the consistency of image density.
B)increase the consistency of image contrast.
C)lengthen exposure latitude.
D)all of the above
A)increase the consistency of image density.
B)increase the consistency of image contrast.
C)lengthen exposure latitude.
D)all of the above
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
12
Fixed kVp systems
A)decrease patient dose.
B)reduce x-ray tube wear.
C)decrease time settings.
D)all of the above
A)decrease patient dose.
B)reduce x-ray tube wear.
C)decrease time settings.
D)all of the above
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
13
When AEC systems are used, the selection of ____ is eliminated.
A)mA
B)exposure time
C)kVp
D)detectors
A)mA
B)exposure time
C)kVp
D)detectors
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
14
The goal of any radiographic exposure system is to provide a method of consistency in the quality of image production.
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
15
Once phantom images have been produced, they must be shown to
A)all diagnosing radiologists only.
B)image quality control radiographers only.
C)diagnosing radiologists and image quality control radiographers.
D)radiology equipment representatives.
A)all diagnosing radiologists only.
B)image quality control radiographers only.
C)diagnosing radiologists and image quality control radiographers.
D)radiology equipment representatives.
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
16
When establishing a technique chart, the initial step involves
A)producing phantom images.
B)performing clinical trials.
C)performing clinical fine-tuning.
D)all of the above
A)producing phantom images.
B)performing clinical trials.
C)performing clinical fine-tuning.
D)all of the above
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
17
Technique systems function best when a large number of variables are permitted to vary.
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
18
Once a technique chart has been established, the process is terminated.
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
19
When establishing technique charts, clinical trials precede phantom testing.
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
20
Variable kVp systems
A)produce higher contrast images than other systems do.
B)enhance the visibility of detail.
C)increase the perception of resolution.
D)all of the above
A)produce higher contrast images than other systems do.
B)enhance the visibility of detail.
C)increase the perception of resolution.
D)all of the above
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
21
All of the following are advantages of the fixed kVp technique system EXCEPT:
A)Patient dose is higher.
B)mAs values are at a minimum based upon thickness.
C)Radiographic contrast is predictable and uniform.
D)A greater exposure latitude is permitted.
A)Patient dose is higher.
B)mAs values are at a minimum based upon thickness.
C)Radiographic contrast is predictable and uniform.
D)A greater exposure latitude is permitted.
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
22
Match the following choices with the correct statement as each relates to exposure systems.
made of tissue-equivalent material
A)calipers
B)Arthur Fuchs
C)APR
D)variable kVp system
E)fixed kVp system
F)AEC
G)Ed C. Jerman
H)phantom
I)fixed kVp systems
J)120 kVp
K)15% rule
L)2 kVp rule
made of tissue-equivalent material
A)calipers
B)Arthur Fuchs
C)APR
D)variable kVp system
E)fixed kVp system
F)AEC
G)Ed C. Jerman
H)phantom
I)fixed kVp systems
J)120 kVp
K)15% rule
L)2 kVp rule
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
23
Match the following choices with the correct statement as each relates to exposure systems.
92 kVp increased to 106 kVp
A)calipers
B)Arthur Fuchs
C)APR
D)variable kVp system
E)fixed kVp system
F)AEC
G)Ed C. Jerman
H)phantom
I)fixed kVp systems
J)120 kVp
K)15% rule
L)2 kVp rule
92 kVp increased to 106 kVp
A)calipers
B)Arthur Fuchs
C)APR
D)variable kVp system
E)fixed kVp system
F)AEC
G)Ed C. Jerman
H)phantom
I)fixed kVp systems
J)120 kVp
K)15% rule
L)2 kVp rule
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
24
With a fixed kVp technique system,
A)radiographic contrast varies based upon the optimum kVp.
B)the average beam energy varies.
C)mAs is varied.
D)all of the above
A)radiographic contrast varies based upon the optimum kVp.
B)the average beam energy varies.
C)mAs is varied.
D)all of the above
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
25
When using a variable kVp exposure technique system,
A)a mAs value is identified for each body part and thickness.
B)small changes in patient thickness can be accommodated with small changes in mAs.
C)kVp varies as a function of patient thickness.
D)all of the above
A)a mAs value is identified for each body part and thickness.
B)small changes in patient thickness can be accommodated with small changes in mAs.
C)kVp varies as a function of patient thickness.
D)all of the above
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
26
Match the following choices with the correct statement as each relates to exposure systems.
became popular in the 1940s
A)calipers
B)Arthur Fuchs
C)APR
D)variable kVp system
E)fixed kVp system
F)AEC
G)Ed C. Jerman
H)phantom
I)fixed kVp systems
J)120 kVp
K)15% rule
L)2 kVp rule
became popular in the 1940s
A)calipers
B)Arthur Fuchs
C)APR
D)variable kVp system
E)fixed kVp system
F)AEC
G)Ed C. Jerman
H)phantom
I)fixed kVp systems
J)120 kVp
K)15% rule
L)2 kVp rule
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
27
Match the following choices with the correct statement as each relates to exposure systems.
mAs is varied to achieve an appropriate image receptor exposure.
A)calipers
B)Arthur Fuchs
C)APR
D)variable kVp system
E)fixed kVp system
F)AEC
G)Ed C. Jerman
H)phantom
I)fixed kVp systems
J)120 kVp
K)15% rule
L)2 kVp rule
mAs is varied to achieve an appropriate image receptor exposure.
A)calipers
B)Arthur Fuchs
C)APR
D)variable kVp system
E)fixed kVp system
F)AEC
G)Ed C. Jerman
H)phantom
I)fixed kVp systems
J)120 kVp
K)15% rule
L)2 kVp rule
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
28
A common term used for AEC is
A)APR.
B)DQE.
C)phototiming.
D)edge detection radiography (EDR).
A)APR.
B)DQE.
C)phototiming.
D)edge detection radiography (EDR).
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
29
Match the following choices with the correct statement as each relates to exposure systems.
preprogrammed exposure techniques
A)calipers
B)Arthur Fuchs
C)APR
D)variable kVp system
E)fixed kVp system
F)AEC
G)Ed C. Jerman
H)phantom
I)fixed kVp systems
J)120 kVp
K)15% rule
L)2 kVp rule
preprogrammed exposure techniques
A)calipers
B)Arthur Fuchs
C)APR
D)variable kVp system
E)fixed kVp system
F)AEC
G)Ed C. Jerman
H)phantom
I)fixed kVp systems
J)120 kVp
K)15% rule
L)2 kVp rule
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
30
Match the following choices with the correct statement as each relates to exposure systems.
father of radiologic technology
A)calipers
B)Arthur Fuchs
C)APR
D)variable kVp system
E)fixed kVp system
F)AEC
G)Ed C. Jerman
H)phantom
I)fixed kVp systems
J)120 kVp
K)15% rule
L)2 kVp rule
father of radiologic technology
A)calipers
B)Arthur Fuchs
C)APR
D)variable kVp system
E)fixed kVp system
F)AEC
G)Ed C. Jerman
H)phantom
I)fixed kVp systems
J)120 kVp
K)15% rule
L)2 kVp rule
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
31
When not using AEC as an exposure technique selection,
A)measuring the patient is very important.
B)AEC detector combinations are critical.
C)the size of the patient is not a factor.
D)none of the above
A)measuring the patient is very important.
B)AEC detector combinations are critical.
C)the size of the patient is not a factor.
D)none of the above
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
32
Match the following choices with the correct statement as each relates to exposure systems.
used to measure part thickness
A)calipers
B)Arthur Fuchs
C)APR
D)variable kVp system
E)fixed kVp system
F)AEC
G)Ed C. Jerman
H)phantom
I)fixed kVp systems
J)120 kVp
K)15% rule
L)2 kVp rule
used to measure part thickness
A)calipers
B)Arthur Fuchs
C)APR
D)variable kVp system
E)fixed kVp system
F)AEC
G)Ed C. Jerman
H)phantom
I)fixed kVp systems
J)120 kVp
K)15% rule
L)2 kVp rule
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
33
Pre-programmed exposure techniques provided by the equipment manufacturer
A)should be viewed as exact for all situations.
B)should be viewed as a starting point for technique selection.
C)are based upon a national standard and widely accepted by everyone.
D)take into account the age of the system and modify techniques accordingly.
A)should be viewed as exact for all situations.
B)should be viewed as a starting point for technique selection.
C)are based upon a national standard and widely accepted by everyone.
D)take into account the age of the system and modify techniques accordingly.
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
34
Anatomically programmed radiography (APR) exposure settings
A)are suggested factors.
B)may be modified by the radiographer.
C)may be reprogrammed by the user.
D)all of the above
A)are suggested factors.
B)may be modified by the radiographer.
C)may be reprogrammed by the user.
D)all of the above
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
35
When developing a fixed kVp exposure system it is important to remember that
A)tube heat loading increases
B)the optimal kVp selected is the maximum kVp established
C)exposure times may be longer.
D)a single kVp value is acceptable for all body parts and thicknesses.
A)tube heat loading increases
B)the optimal kVp selected is the maximum kVp established
C)exposure times may be longer.
D)a single kVp value is acceptable for all body parts and thicknesses.
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
36
Match the following choices with the correct statement as each relates to exposure systems.
also known as phototiming
A)calipers
B)Arthur Fuchs
C)APR
D)variable kVp system
E)fixed kVp system
F)AEC
G)Ed C. Jerman
H)phantom
I)fixed kVp systems
J)120 kVp
K)15% rule
L)2 kVp rule
also known as phototiming
A)calipers
B)Arthur Fuchs
C)APR
D)variable kVp system
E)fixed kVp system
F)AEC
G)Ed C. Jerman
H)phantom
I)fixed kVp systems
J)120 kVp
K)15% rule
L)2 kVp rule
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
37
When formulating an exposure technique chart system, a successful sequence of steps is as follows:
1) clinical trials
2) clinical fine-tuning
3) ongoing fine-tuning
4) creation of phantom images
5) using the phantom images to extrapolate a chart
6) selecting the optimal phantom image
7) phantom testing
A)1, 4, 5, 2, 3, 6, 7
B)4, 6, 1, 7, 2, 3, 5
C)4, 6, 5, 7, 1, 2, 3
D)7, 4, 5, 6, 1, 2, 3
1) clinical trials
2) clinical fine-tuning
3) ongoing fine-tuning
4) creation of phantom images
5) using the phantom images to extrapolate a chart
6) selecting the optimal phantom image
7) phantom testing
A)1, 4, 5, 2, 3, 6, 7
B)4, 6, 1, 7, 2, 3, 5
C)4, 6, 5, 7, 1, 2, 3
D)7, 4, 5, 6, 1, 2, 3
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
38
Match the following choices with the correct statement as each relates to exposure systems.
developed a scientific approach to exposure techniques
A)calipers
B)Arthur Fuchs
C)APR
D)variable kVp system
E)fixed kVp system
F)AEC
G)Ed C. Jerman
H)phantom
I)fixed kVp systems
J)120 kVp
K)15% rule
L)2 kVp rule
developed a scientific approach to exposure techniques
A)calipers
B)Arthur Fuchs
C)APR
D)variable kVp system
E)fixed kVp system
F)AEC
G)Ed C. Jerman
H)phantom
I)fixed kVp systems
J)120 kVp
K)15% rule
L)2 kVp rule
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck
39
Match the following choices with the correct statement as each relates to exposure systems.
inconsistent radiographic image contrast
A)calipers
B)Arthur Fuchs
C)APR
D)variable kVp system
E)fixed kVp system
F)AEC
G)Ed C. Jerman
H)phantom
I)fixed kVp systems
J)120 kVp
K)15% rule
L)2 kVp rule
inconsistent radiographic image contrast
A)calipers
B)Arthur Fuchs
C)APR
D)variable kVp system
E)fixed kVp system
F)AEC
G)Ed C. Jerman
H)phantom
I)fixed kVp systems
J)120 kVp
K)15% rule
L)2 kVp rule
Unlock Deck
Unlock for access to all 39 flashcards in this deck.
Unlock Deck
k this deck