Once phantom images have been produced, they must be shown to

Free
(Multiple Choice)
4.9/5
(44)
Correct Answer:
Verified

C

Match the following choices with the correct statement as each relates to exposure systems. -92 kVp increased to 106 kVp

Free
(Multiple Choice)
4.9/5
(38)
Correct Answer:
Verified

K

Pre-programmed exposure techniques provided by the equipment manufacturer

Free
(Multiple Choice)
4.9/5
(36)
Correct Answer:
Verified

B

Technique systems function best when a single variable is permitted to vary.

(True/False)
4.9/5
(33)

Technique systems function best when a

(Multiple Choice)
5.0/5
(36)

Fixed kVp systems

(Multiple Choice)
4.8/5
(37)

Match the following choices with the correct statement as each relates to exposure systems. -mAs is varied to achieve an appropriate image receptor exposure.

(Multiple Choice)
4.7/5
(39)

Anatomically programmed radiography (APR) exposure settings

(Multiple Choice)
4.8/5
(35)

Fixed kVp systems produce more scatter radiation than other systems.

(True/False)
4.8/5
(37)

Most x-ray generators permit finer adjustment of kVp stations than of time or mA settings.

(True/False)
4.8/5
(46)

When a new piece of imaging equipment is added to the imaging chain, technique charts must be re-established.

(True/False)
4.8/5
(35)

When using a variable kVp exposure technique system,

(Multiple Choice)
4.7/5
(45)

Variable kVp systems

(Multiple Choice)
4.9/5
(36)

Technique systems function best when a large number of variables are permitted to vary.

(True/False)
5.0/5
(32)

All of the following are advantages of the fixed kVp technique system EXCEPT:

(Multiple Choice)
4.7/5
(44)

Once a technique chart has been established, the process is terminated.

(True/False)
4.8/5
(34)

When not using AEC as an exposure technique selection,

(Multiple Choice)
4.8/5
(37)

Fixed kVp systems

(Multiple Choice)
4.8/5
(30)

When formulating an exposure technique chart system, a successful sequence of steps is as follows: 1) clinical trials 2) clinical fine-tuning 3) ongoing fine-tuning 4) creation of phantom images 5) using the phantom images to extrapolate a chart 6) selecting the optimal phantom image 7) phantom testing

(Multiple Choice)
4.9/5
(45)

Fixed kVp systems tend to decrease patient dose.

(True/False)
4.8/5
(32)