Deck 13: Drainage,waste,and Vent Segments and Sizing

Full screen (f)
exit full mode
Question
MATCHING
Match the following terms:
a.Loop Vent
b.Stack Vent
c.Septic tank
d.Trap Distance
e.Soil Stack
f.Common Vent
g.Drainage Fixture Unit
h.Perc test
i.Effluent
j.Stack
k.Relief Vent
Fabricated holding tank or structure to contain sewage and solids.
Use Space or
up arrow
down arrow
to flip the card.
Question
All horizontal drains must have adequate slope to evacuate wastewater and solids.
Question
Cleanouts are required based on changes in direction,distance,and at the base of a waste stack.
Question
A ____________________ and a horizontal branch are often the same pipe,depending on the complexity of piping configuration.
Question
MATCHING
Match the following terms:
a.Loop Vent
b.Stack Vent
c.Septic tank
d.Trap Distance
e.Soil Stack
f.Common Vent
g.Drainage Fixture Unit
h.Perc test
i.Effluent
j.Stack
k.Relief Vent
Special vent similar to a circuit vent,except it terminates connecting to a stack vent instead of a vent stack;only used on a top floor or at the highest branch interval.
Question
____________________ is a drain for allowable fixtures being utilized as a vent for other fixtures.
Question
MATCHING
Match the following terms:
a.Loop Vent
b.Stack Vent
c.Septic tank
d.Trap Distance
e.Soil Stack
f.Common Vent
g.Drainage Fixture Unit
h.Perc test
i.Effluent
j.Stack
k.Relief Vent
Vent serving two fixture drains located on the same floor and either connecting at the same height or at different heights to the drain.
Question
The building drain is sized based on the drainage load of the entire system,and minimum sizing is dictated by codes.
Question
Most codes allow any pipe greater than 8" to be served with a 4" cleanout.
Question
All codes dictate that no vent be extended to open air.
Question
Many codes state a building drain must extend at least __________ and a maximum of __________ from the exterior of the building.
Question
All relief vents are sized based on their specific use and determined by using a codebook,but cannot be less than __________ the diameter of the drain they serve,and no smaller than __________".
Question
A fixture drain installed aboveground is sized based on the particular fixture served.
Question
MATCHING
Match the following terms:
a.Loop Vent
b.Stack Vent
c.Septic tank
d.Trap Distance
e.Soil Stack
f.Common Vent
g.Drainage Fixture Unit
h.Perc test
i.Effluent
j.Stack
k.Relief Vent
Pipe circulating air between a drainage and vent system.It has several specific areas of installation and is sized based on its use.
Question
The _______________ is the main vertical drain pipe that begins with its connection to the building drain and terminates with its connection to the stack vent.
Question
Most codes only allow a maximum of three toilets on a 3" horizontal branch.
Question
Layout for a DWV system is typically the first process completed on a project,and other piping systems are installed around the DWV system.
Question
The IPC and UPC have some different drainage fixture unit values and and minimum trap and drain sizes for the same fixtures.
Question
Most codes dictate that the stack vent cannot transition horizontally until it is 8" above the flood level rim of the highest fixture connecting to the waste stack.
Question
Most codes allow a 2" fixture drain to be served by a 1-1/2" removable slip joint.
Question
List the major components of a domestic water vent.
Question
MATCHING
Match the following terms:
a.Loop Vent
b.Stack Vent
c.Septic tank
d.Trap Distance
e.Soil Stack
f.Common Vent
g.Drainage Fixture Unit
h.Perc test
i.Effluent
j.Stack
k.Relief Vent
Dimension a trap weir is located from its protective vent.
Question
What are the three flow positions of a drainage system?
Question
MATCHING
Match the following terms:
a.Loop Vent
b.Stack Vent
c.Septic tank
d.Trap Distance
e.Soil Stack
f.Common Vent
g.Drainage Fixture Unit
h.Perc test
i.Effluent
j.Stack
k.Relief Vent
Abbreviated as dfu;a determining factor based on rate of flow measured in gallons per minute or liters per second into a drainage system from a plumbing fixture;used to size pipe.
Question
MATCHING
Match the following terms:
a.Loop Vent
b.Stack Vent
c.Septic tank
d.Trap Distance
e.Soil Stack
f.Common Vent
g.Drainage Fixture Unit
h.Perc test
i.Effluent
j.Stack
k.Relief Vent
Vertical pipe conveying wastewater that contains fecal matter;is the same pipe as a waste stack and can be installed with horizontal offsets.
Question
MATCHING
Match the following terms:
a.Loop Vent
b.Stack Vent
c.Septic tank
d.Trap Distance
e.Soil Stack
f.Common Vent
g.Drainage Fixture Unit
h.Perc test
i.Effluent
j.Stack
k.Relief Vent
Wastewater that has been separated from solids,but may contain dissolved sewage solids.
Question
MATCHING
Match the following terms:
a.Loop Vent
b.Stack Vent
c.Septic tank
d.Trap Distance
e.Soil Stack
f.Common Vent
g.Drainage Fixture Unit
h.Perc test
i.Effluent
j.Stack
k.Relief Vent
Vertical pipe that is at least one story in height.Can be installed with horizontal offsets.
Question
MATCHING
Match the following terms:
a.Loop Vent
b.Stack Vent
c.Septic tank
d.Trap Distance
e.Soil Stack
f.Common Vent
g.Drainage Fixture Unit
h.Perc test
i.Effluent
j.Stack
k.Relief Vent
Trade name for percolation test;a method to evaluate percolation conditions of soil.
Question
What are the two legal methods of waste termination?
Question
MATCHING
Match the following terms:
a.Loop Vent
b.Stack Vent
c.Septic tank
d.Trap Distance
e.Soil Stack
f.Common Vent
g.Drainage Fixture Unit
h.Perc test
i.Effluent
j.Stack
k.Relief Vent
Vertical pipe that connects to a soil or waste stack and extends to open air or connects with another approved vent;can be installed with horizontal offsets.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/30
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 13: Drainage,waste,and Vent Segments and Sizing
1
MATCHING
Match the following terms:
a.Loop Vent
b.Stack Vent
c.Septic tank
d.Trap Distance
e.Soil Stack
f.Common Vent
g.Drainage Fixture Unit
h.Perc test
i.Effluent
j.Stack
k.Relief Vent
Fabricated holding tank or structure to contain sewage and solids.
C
2
All horizontal drains must have adequate slope to evacuate wastewater and solids.
True
3
Cleanouts are required based on changes in direction,distance,and at the base of a waste stack.
True
4
A ____________________ and a horizontal branch are often the same pipe,depending on the complexity of piping configuration.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
5
MATCHING
Match the following terms:
a.Loop Vent
b.Stack Vent
c.Septic tank
d.Trap Distance
e.Soil Stack
f.Common Vent
g.Drainage Fixture Unit
h.Perc test
i.Effluent
j.Stack
k.Relief Vent
Special vent similar to a circuit vent,except it terminates connecting to a stack vent instead of a vent stack;only used on a top floor or at the highest branch interval.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
6
____________________ is a drain for allowable fixtures being utilized as a vent for other fixtures.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
7
MATCHING
Match the following terms:
a.Loop Vent
b.Stack Vent
c.Septic tank
d.Trap Distance
e.Soil Stack
f.Common Vent
g.Drainage Fixture Unit
h.Perc test
i.Effluent
j.Stack
k.Relief Vent
Vent serving two fixture drains located on the same floor and either connecting at the same height or at different heights to the drain.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
8
The building drain is sized based on the drainage load of the entire system,and minimum sizing is dictated by codes.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
9
Most codes allow any pipe greater than 8" to be served with a 4" cleanout.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
10
All codes dictate that no vent be extended to open air.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
11
Many codes state a building drain must extend at least __________ and a maximum of __________ from the exterior of the building.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
12
All relief vents are sized based on their specific use and determined by using a codebook,but cannot be less than __________ the diameter of the drain they serve,and no smaller than __________".
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
13
A fixture drain installed aboveground is sized based on the particular fixture served.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
14
MATCHING
Match the following terms:
a.Loop Vent
b.Stack Vent
c.Septic tank
d.Trap Distance
e.Soil Stack
f.Common Vent
g.Drainage Fixture Unit
h.Perc test
i.Effluent
j.Stack
k.Relief Vent
Pipe circulating air between a drainage and vent system.It has several specific areas of installation and is sized based on its use.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
15
The _______________ is the main vertical drain pipe that begins with its connection to the building drain and terminates with its connection to the stack vent.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
16
Most codes only allow a maximum of three toilets on a 3" horizontal branch.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
17
Layout for a DWV system is typically the first process completed on a project,and other piping systems are installed around the DWV system.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
18
The IPC and UPC have some different drainage fixture unit values and and minimum trap and drain sizes for the same fixtures.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
19
Most codes dictate that the stack vent cannot transition horizontally until it is 8" above the flood level rim of the highest fixture connecting to the waste stack.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
20
Most codes allow a 2" fixture drain to be served by a 1-1/2" removable slip joint.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
21
List the major components of a domestic water vent.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
22
MATCHING
Match the following terms:
a.Loop Vent
b.Stack Vent
c.Septic tank
d.Trap Distance
e.Soil Stack
f.Common Vent
g.Drainage Fixture Unit
h.Perc test
i.Effluent
j.Stack
k.Relief Vent
Dimension a trap weir is located from its protective vent.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
23
What are the three flow positions of a drainage system?
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
24
MATCHING
Match the following terms:
a.Loop Vent
b.Stack Vent
c.Septic tank
d.Trap Distance
e.Soil Stack
f.Common Vent
g.Drainage Fixture Unit
h.Perc test
i.Effluent
j.Stack
k.Relief Vent
Abbreviated as dfu;a determining factor based on rate of flow measured in gallons per minute or liters per second into a drainage system from a plumbing fixture;used to size pipe.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
25
MATCHING
Match the following terms:
a.Loop Vent
b.Stack Vent
c.Septic tank
d.Trap Distance
e.Soil Stack
f.Common Vent
g.Drainage Fixture Unit
h.Perc test
i.Effluent
j.Stack
k.Relief Vent
Vertical pipe conveying wastewater that contains fecal matter;is the same pipe as a waste stack and can be installed with horizontal offsets.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
26
MATCHING
Match the following terms:
a.Loop Vent
b.Stack Vent
c.Septic tank
d.Trap Distance
e.Soil Stack
f.Common Vent
g.Drainage Fixture Unit
h.Perc test
i.Effluent
j.Stack
k.Relief Vent
Wastewater that has been separated from solids,but may contain dissolved sewage solids.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
27
MATCHING
Match the following terms:
a.Loop Vent
b.Stack Vent
c.Septic tank
d.Trap Distance
e.Soil Stack
f.Common Vent
g.Drainage Fixture Unit
h.Perc test
i.Effluent
j.Stack
k.Relief Vent
Vertical pipe that is at least one story in height.Can be installed with horizontal offsets.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
28
MATCHING
Match the following terms:
a.Loop Vent
b.Stack Vent
c.Septic tank
d.Trap Distance
e.Soil Stack
f.Common Vent
g.Drainage Fixture Unit
h.Perc test
i.Effluent
j.Stack
k.Relief Vent
Trade name for percolation test;a method to evaluate percolation conditions of soil.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
29
What are the two legal methods of waste termination?
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
30
MATCHING
Match the following terms:
a.Loop Vent
b.Stack Vent
c.Septic tank
d.Trap Distance
e.Soil Stack
f.Common Vent
g.Drainage Fixture Unit
h.Perc test
i.Effluent
j.Stack
k.Relief Vent
Vertical pipe that connects to a soil or waste stack and extends to open air or connects with another approved vent;can be installed with horizontal offsets.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 30 flashcards in this deck.