Exam 13: Plc Installation Practices,editing,and Troubleshooting
Exam 1: Programmable Logic Controllers Plcs: an Overview59 Questions
Exam 2: Plc Hardware Components84 Questions
Exam 3: Number Systems and Codes37 Questions
Exam 4: Fundamentals of Logic48 Questions
Exam 5: Basics of Plc Programming80 Questions
Exam 6: Developing Fundamental Plc Wiring Diagrams and Ladder Logic Programs85 Questions
Exam 7: Programming Timers58 Questions
Exam 8: Programming Counters62 Questions
Exam 9: Program Control Instructions89 Questions
Exam 10: Data Manipulation Instructions83 Questions
Exam 11: Math Instructions59 Questions
Exam 12: Sequencer and Shift Register Instructions71 Questions
Exam 13: Plc Installation Practices,editing,and Troubleshooting87 Questions
Exam 14: Process Control,network Systems and Scada112 Questions
Exam 15: Controllogix Controllers - Part 1 - Memory and Project Organization65 Questions
Exam 16: Controllogix Controllers - Part 2 - Bit Level Programming34 Questions
Exam 17: Controllogix Controllers - Part 3 - Programming Timers23 Questions
Exam 18: Controllogix Controllers - Part 4 - Programming Counters13 Questions
Exam 19: Controllogix Controllers - Part 5 - Math,comparison,and Move Instructions15 Questions
Exam 20: Controllogix Controllers - Part 6 - Function Block Programming22 Questions
Select questions type
If the scan time is too long,a watchdog error will be declared.
Free
(True/False)
4.9/5
(34)
Correct Answer:
True
Assume an open in the field wiring is suspected between the output module and output load device.This condition would be confirmed if:
Free
(Multiple Choice)
4.8/5
(34)
Correct Answer:
A
PLC malfunctions due to electrical noise usually produce temporary occurrences of operating errors.
Free
(True/False)
4.8/5
(37)
Correct Answer:
True
One of the diagnostic checks carried out by the processor is the proper operation of all I/O devices.
(True/False)
4.9/5
(39)
Which of the following would not normally be located within the PLC enclosure?
(Multiple Choice)
4.9/5
(33)
The cross reference function allows you to view the transition history of a data table value.
(True/False)
4.8/5
(39)
An enclosure is used to shield the controller from electrical noise and airborne contaminants.
(True/False)
4.9/5
(35)
Which of the choices of the troubleshooting guide shown indicates a problem with the wiring to the output device or the output device itself? 

(Multiple Choice)
4.9/5
(34)
The status indicator on an input module will normally be illuminated if the input device is off and examined for an off condition.
(True/False)
4.8/5
(31)
Communications protocol is a standardized method for establishing communications between different PLC devices.
(True/False)
4.7/5
(39)
Certain input field devices may have a small leakage current when they are:
(Multiple Choice)
4.9/5
(46)
Proper grounding procedures for a PLC installation specify that:
(Multiple Choice)
4.9/5
(32)
Typically,PLC systems installed inside an enclosure can withstand a maximum of:
(Multiple Choice)
4.9/5
(35)
The input wiring or device is suspected as being the source of a PLC problem.If this circuit is not at fault,then the status indicator on the input module should be illuminated when the input device is:
(Multiple Choice)
4.8/5
(33)
The offline programming mode permits the user to change the program during the machine operation.
(True/False)
4.9/5
(25)
A bleeder resistor can be connected to drain off unwanted module leakage current.
(True/False)
4.9/5
(44)
Showing 1 - 20 of 87
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)