Exam 11: Math Instructions
Exam 1: Programmable Logic Controllers Plcs: an Overview59 Questions
Exam 2: Plc Hardware Components84 Questions
Exam 3: Number Systems and Codes37 Questions
Exam 4: Fundamentals of Logic48 Questions
Exam 5: Basics of Plc Programming80 Questions
Exam 6: Developing Fundamental Plc Wiring Diagrams and Ladder Logic Programs85 Questions
Exam 7: Programming Timers58 Questions
Exam 8: Programming Counters62 Questions
Exam 9: Program Control Instructions89 Questions
Exam 10: Data Manipulation Instructions83 Questions
Exam 11: Math Instructions59 Questions
Exam 12: Sequencer and Shift Register Instructions71 Questions
Exam 13: Plc Installation Practices,editing,and Troubleshooting87 Questions
Exam 14: Process Control,network Systems and Scada112 Questions
Exam 15: Controllogix Controllers - Part 1 - Memory and Project Organization65 Questions
Exam 16: Controllogix Controllers - Part 2 - Bit Level Programming34 Questions
Exam 17: Controllogix Controllers - Part 3 - Programming Timers23 Questions
Exam 18: Controllogix Controllers - Part 4 - Programming Counters13 Questions
Exam 19: Controllogix Controllers - Part 5 - Math,comparison,and Move Instructions15 Questions
Exam 20: Controllogix Controllers - Part 6 - Function Block Programming22 Questions
Select questions type
Assume output 0:3/2 is energized and the values of the numbers stored in words N7:0 and N7:1 are 500 and 40,respectively.The value of the number stored in word N7:8 would be 13. 

Free
(True/False)
4.9/5
(37)
Correct Answer:
True
Assume the accumulated count of counter C5:0 and C5:1 to be 124 and 248,respectively.As a result: 

Free
(Multiple Choice)
4.8/5
(40)
Correct Answer:
A
All PLC manufacturers use the same format for math instructions.
Free
(True/False)
4.9/5
(40)
Correct Answer:
False
Assume that the light is to come on after a total count of 120.As a result: 

(Multiple Choice)
4.9/5
(36)
The program is telling the processor to energize output 0:6/2 whenever the value of N7:8 is equal to that of N7:4. 

(True/False)
4.8/5
(39)
The rung logic is telling the processor to divide the value of word N7:4 by the value of N7:6. 

(True/False)
4.9/5
(36)
The preset full weight of the vessel is changed by changing: 

(Multiple Choice)
4.8/5
(33)
The program is telling the processor to energize output 0:2/3 whenever the sum of N7:5 and N7:8 is greater or equal to that of N7:4. 

(True/False)
4.7/5
(34)
There is no limit to the maximum value a PLC math function can store.
(True/False)
4.9/5
(40)
File arithmetic instructions are designed to perform math operations on single words.
(True/False)
4.8/5
(33)
For the program of Figure 11-6,the set-point temperature is set by the number stored in: 

(Multiple Choice)
4.8/5
(38)
Assume the set-point temperature is changed to 200 F.As a result,the number stored in N7:0 would be:

(Multiple Choice)
4.9/5
(39)