Which of the following pulse oximeters can measure carboxyhemoglobin (COHb)?

Free
(Multiple Choice)
4.9/5
(33)
Correct Answer:
Verified

C

Which of the following are indications for arterial blood gas analysis according to the American Association for Respiratory Care (AARC) Clinical Practice Guideline: Blood Gas Analysis and Hemoximeter: 2001 Revision and Update? I. Assess a patient's ventilatory status. II. Assess a patient's acid-base status. III. Assess a patient's oxygenation status. IV. Monitor response to therapeutic intervention.

Free
(Multiple Choice)
4.9/5
(41)
Correct Answer:
Verified

D

Indirect calorimetry may be used to assess: I. O2 consumption II CO2 production III. resting energy expenditure IV. tidal and minute volumes

Free
(Multiple Choice)
4.7/5
(37)
Correct Answer:
Verified

D

The barometric pressure is 745 mmHg, and you are calibrating a blood gas instrument with a mixture of 5% PCO2 and 10% O2. What are your expected calibration results? I. 37.3 mmHg II. 74.5 mmHg III. 34.9 mmHg IV. 69.8 mmHg

(Multiple Choice)
4.8/5
(28)

Six or more quality-control results on the same side of the mean is termed:

(Multiple Choice)
4.9/5
(26)

When hooking up a patient to an impedance plethysmographic apnea monitor:

(Multiple Choice)
4.7/5
(35)

The barometric pressure is 760 mmHg, and you are calibrating a blood gas instrument with a mixture of 5% PCO2 and 10% O2. What are your expected calibration results? I. 38.0 mmHg II. 76.0 mmHg III. 35.7 mmHg IV. 71.3 mmHg

(Multiple Choice)
4.7/5
(36)

Which of the following oximeters would be classified as a "finger tip" oximeter?

(Multiple Choice)
4.9/5
(29)

Which of the following are flow-measuring devices? I. water seal spirometer II. Fleisch pneumotachometer III. dry rolling seal spirometer IV. thermal anemometer

(Multiple Choice)
4.9/5
(34)

Which of the following reference electrodes does the PCO2 system use?

(Multiple Choice)
4.8/5
(37)

Which of the following uses a differential pressure to measure flow?

(Multiple Choice)
4.7/5
(29)

You are going to assess the effect of a small-volume nebulizer treatment with a bronchodilator. Which of the following will give you the best measure of the bronchodilator's effect?

(Multiple Choice)
4.9/5
(39)

What are the limitations to pulse oximetry according to the American Association for Respiratory Care (AARC) Clinical Practice Guideline: Pulse Oximetry? I. motion artifact II. abnormal hemoglobins III. ambient light IV. intravascular dyes

(Multiple Choice)
4.9/5
(36)

Which of the following are volume-displacement measuring devices? I. water seal spirometer II. Fleisch pneumotachometer III. dry rolling seal spirometer IV. thermal anemometer

(Multiple Choice)
4.9/5
(28)

If a transcutaneous electrode is responding slowly you should: I. remembrane the electrode II. recalibrate the electrode III. change the electrode site

(Multiple Choice)
4.8/5
(42)

Which of the following hemoglobin variants cannot combine reversibly with oxygen? I. reduced hemoglobin II. oxyhemoglobin III. methemoglobin IV. carboxyhemoglobin

(Multiple Choice)
4.8/5
(25)

Why must the electrode of a transcutaneous monitor be moved frequently to different locations on the patient's skin?

(Multiple Choice)
4.9/5
(40)

The PCO2 system's membrane is made of:

(Multiple Choice)
4.8/5
(34)

A means of plotting quality-control results graphically about the mean is termed:

(Multiple Choice)
4.7/5
(35)

A Wright respirometer is most accurate between the flow rates of:

(Multiple Choice)
4.7/5
(37)