Exam 8: Charging Systems

arrow
  • Select Tags
search iconSearch Question
flashcardsStudy Flashcards
  • Select Tags

Technician A says that Intelli-check is best used as a first-level diagnostic tool.Technician B says that if Intelli-check illuminates one of the four failure indicator LEDs,it would be good practice to have a technician skilled in electrical systems to check the system before replacing components.Who is correct?

Free
(Multiple Choice)
4.9/5
(33)
Correct Answer:
Verified

C

Technician A says that the Delco-Remy Intelli-check instrument can pin-point difficult to diagnose,charging circuit problems.Technician B says that an Intelli-check test procedure produces one of 5 status outcomes after testing.Who is correct?

Free
(Multiple Choice)
4.9/5
(34)
Correct Answer:
Verified

B

How is field current routed through an alternator?

Free
(Multiple Choice)
4.9/5
(38)
Correct Answer:
Verified

D

Which of the following alternator failures could result in undercharging?

(Multiple Choice)
4.9/5
(37)

How many windings should a typical truck alternator stator have?

(Multiple Choice)
4.9/5
(30)

How are the stator windings in a typical truck alternator configured?

(Multiple Choice)
4.8/5
(33)

Which of the following defects could result in an undercharged battery?

(Multiple Choice)
4.9/5
(31)

Which of the following statements about the diagnostic practice of full-fielding an alternator is true?

(Multiple Choice)
4.8/5
(28)

Which of the following describes the role of a rectifier in an alternator?

(Multiple Choice)
4.7/5
(38)

Technician A says that a 100 amp alternator can draw as much as 7 horsepower from the engine.Technician B says that an alternator is switched in and out of its effective cycle by the voltage regulator.Who is correct?

(Multiple Choice)
4.9/5
(37)

If you do not apply an electrical load to the batteries when full-fielding an alternator,which of the following could result?

(Multiple Choice)
4.9/5
(35)

Technician A says that to perform a maximum output test on a typical heavy-duty truck charging circuit,the engine should be run at 1500 rpm.Technician B says that alternator rpm is typically at least three times engine rpm.Who is correct?

(Multiple Choice)
4.8/5
(44)

Which of the following conditions will shorten the life of batteries?

(Multiple Choice)
4.8/5
(32)

Technician A says that a Delco/Remy 55 SI alternator rated at 420 amps is often used in motor coach applications.Technician B says that a Delcotron 33/34 SI can be rated as high as 300 amps.Who is correct?

(Multiple Choice)
4.8/5
(41)

What specific component on a truck charging system does an AC leakage test evaluate?

(Multiple Choice)
4.7/5
(37)

Which of the following best explains how an alternator is driven by truck engine at a higher speed than engine rpm?

(Multiple Choice)
4.9/5
(41)

Which of the following statements about how electrical current flow is induced in an alternator is correct?

(Multiple Choice)
4.9/5
(39)

When testing a Delcotron 33/34 SI alternator at an ambient temperature of 80 degrees Fahrenheit,what would be a within specification field current draw?

(Multiple Choice)
4.9/5
(34)

Technician A says that to perform an AC leakage test,a DMM should be set to auto-range AC with one test lead placed on the alternator insulated terminal,and the other on chassis ground.Technician B says that when performing an AC leakage test,the engine should be run at 1500 rpm.Who is correct?

(Multiple Choice)
4.9/5
(39)

What is the function of the diode trio in an internally regulated truck alternator?

(Multiple Choice)
4.9/5
(34)