Exam 9: Temperature Control
Exam 1: Transformers and Power Supplies10 Questions
Exam 2: Fuses, Disconnect Switches, and Circuit Breakers10 Questions
Exam 3: Control Units for Switching and Communication8 Questions
Exam 4: Relays10 Questions
Exam 5: Solenoids9 Questions
Exam 6: Types of Control10 Questions
Exam 7: Motion Control Devices8 Questions
Exam 8: Pressure Control10 Questions
Exam 9: Temperature Control10 Questions
Exam 10: Time Control10 Questions
Exam 11: Count Control9 Questions
Exam 12: Control Circuits10 Questions
Exam 13: Motors and Drives10 Questions
Exam 14: Motor Starters10 Questions
Exam 15: Introduction to Programmable Control10 Questions
Exam 16: Industrial Data Communications10 Questions
Exam 17: Quality Control10 Questions
Exam 18: Safety10 Questions
Exam 19: Troubleshooting10 Questions
Exam 20: Designing Control Systems for Easy Maintenance10 Questions
Select questions type
The main difference among temperature switches is the means by which the temperature information is transferred from the sensing element to the switching element.
Free
(True/False)
4.8/5
(37)
Correct Answer:
True
Temperature switches using differential expansion of metals may be of two different
types. One uses a mechanical link; the other uses a ____________________.
Free
(Short Answer)
4.9/5
(43)
Correct Answer:
fused bimetal
The ____ is a semiconductor whose resistance decreases with increasing temperature.
Free
(Multiple Choice)
4.8/5
(40)
Correct Answer:
B
____ is the difference in temperature at the sensing element between make and break of the controller's contacts when the controller is cycled.
(Multiple Choice)
4.9/5
(43)
Compared to thermocouples, RTDs are less repeatable and less stable.
(True/False)
4.8/5
(41)
_____________________ control turns the heating elements on or off based on the difference between the actual temperature and the set-point.
(Short Answer)
4.8/5
(47)
There are three basic types of sensing element: (1) ____________________, (2) differential expansion of metal, and (3) expansion of fluid, gas, or vapor.
(Short Answer)
4.8/5
(35)
With reference to temperature controllers, ____ refers to the operational functions that a controller has.
(Multiple Choice)
4.9/5
(29)
The temperature switch (thermostat) is generally used at ____________________ temperatures than the pyrometer.
(Short Answer)
4.9/5
(29)
The actual temperature in an on/off system will always fluctuate about some value.
(True/False)
4.8/5
(41)
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)