Exam 20: Checking Out and Troubleshooting Electrical Wiring Systems
Exam 1: Residential Workplace Safety47 Questions
Exam 2: Hardware and Materials Used in Residential Wiring53 Questions
Exam 3: Tools Used in Residential Wiring46 Questions
Exam 4: Test and Measurement Instruments Used in Residential Wiring51 Questions
Exam 5: Understanding Residential Building Plans41 Questions
Exam 6: Determining Branch Circuit, Feeder Circuit, and Service Entrance Requirements49 Questions
Exam 7: Introduction to Residential Service Entrances48 Questions
Exam 8: Service Entrance Equipment and Installation42 Questions
Exam 9: General Nec Requirements for Rough-In Wiring49 Questions
Exam 10: Electrical Box Installation44 Questions
Exam 11: Cable Installation49 Questions
Exam 12: Raceway Installation47 Questions
Exam 13: Switching Circuit Installation44 Questions
Exam 14: Branch-Circuit Installation47 Questions
Exam 15: Special Residential Wiring Situations49 Questions
Exam 16: Video, Voice, and Data Wiring Installation52 Questions
Exam 17: Lighting Fixture Installation52 Questions
Exam 18: Device Installation46 Questions
Exam 19: Service Panel Trim-Out42 Questions
Exam 20: Checking Out and Troubleshooting Electrical Wiring Systems41 Questions
Exam 21: Green Wiring Practices32 Questions
Exam 22: Photovoltaic Pv System Installation44 Questions
Select questions type
A continuity tester can be used to find short circuits, ground faults, and open circuits in de-energized circuits.
Free
(True/False)
4.8/5
(39)
Correct Answer:
True
When holes are bored through wood framing members, they must be at least __________ inches from the nearest edge of the wood member.
Free
(Multiple Choice)
4.8/5
(34)
Correct Answer:
C
An electrician tests a three-way switching circuit.The lighting load can be turned OFF and then ON at each of the three-way switch locations.However, when one three-way switch toggle is left in the up position, toggling the other three-way switch does not cause the lighting load to come on.The likely cause is __________.
Free
(Multiple Choice)
4.8/5
(38)
Correct Answer:
C
The rating of the __________ determines the rating of a branch or feeder circuit.
(Multiple Choice)
4.9/5
(32)
A(n) __________ is a circuit that is energized but does not allow useful current to flow on the circuit because of a break in the current path.
(Multiple Choice)
4.7/5
(36)
NEC Table __________ contains the requirements for direct burial of conductors and raceways.
(Multiple Choice)
4.8/5
(36)
An electrician is testing a 15-ampere, 125-volt rated duplex receptacle with a voltage tester.The tester indicates 120 volts between the ungrounded slot and the grounded slot.The tester also indicates 120 volts between the grounded slot and the grounding slot.The likely cause is __________.
(Multiple Choice)
4.9/5
(41)
At least __________ 20-ampere small appliance branch circuits are (is) required to serve kitchen countertop surfaces.
(Multiple Choice)
4.9/5
(43)
Explain "feed through" as it applies to using a continuity tester when testing a lighting circuit.
(Essay)
4.7/5
(35)
The house electrical system may be grounded using a metal water pipe in direct contact with the earth for at least __________ feet.
(Multiple Choice)
4.7/5
(34)
Recessed lighting fixtures installed in insulated ceilings so that the insulation is covering the fixture must be labeled ____________________.
(Essay)
4.7/5
(37)
A feed-though condition may cause false readings during circuit testing and can happen when a load is still connected to the circuit being tested.
(True/False)
4.9/5
(32)
A(n) __________ is an unintended low-resistance path through which current flows around, rather than along, a circuit's intended current path.
(Multiple Choice)
4.9/5
(35)
According to the NEC, lighting fixtures must be installed in clothes closets.
(True/False)
4.8/5
(38)
In a sub-panel, a green bonding screw provided by the panel manufacturer must be installed to electrically bond the grounded feeder conductor and the equipment-grounding conductors to the panel enclosure.
(True/False)
4.8/5
(35)
When there is a short in a branch circuit, a high circuit resistance develops that results in low amounts of current flowing on the circuit.
(True/False)
4.7/5
(35)
Regular fluorescent ballasts are designed to light fluorescent lamps in an ambient temperature of __________ degrees F or higher.
(Multiple Choice)
4.8/5
(37)
When testing a "live" 50-ampere, 125/250-volt range receptacle using a voltage tester, you should get a 240-volt reading when measuring from the grounded conductor connection (W slot) to either ungrounded conductor connection (X or Y slot).
(True/False)
4.8/5
(40)
The NEC requires a minimum of __________-20 ampere bathroom branch circuit in a dwelling unit.
(Multiple Choice)
4.9/5
(33)
Showing 1 - 20 of 41
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)