Exam 20: Checking Out and Troubleshooting Electrical Wiring Systems
Exam 1: Residential Workplace Safety47 Questions
Exam 2: Hardware and Materials Used in Residential Wiring53 Questions
Exam 3: Tools Used in Residential Wiring46 Questions
Exam 4: Test and Measurement Instruments Used in Residential Wiring51 Questions
Exam 5: Understanding Residential Building Plans41 Questions
Exam 6: Determining Branch Circuit, Feeder Circuit, and Service Entrance Requirements49 Questions
Exam 7: Introduction to Residential Service Entrances48 Questions
Exam 8: Service Entrance Equipment and Installation42 Questions
Exam 9: General Nec Requirements for Rough-In Wiring49 Questions
Exam 10: Electrical Box Installation44 Questions
Exam 11: Cable Installation49 Questions
Exam 12: Raceway Installation47 Questions
Exam 13: Switching Circuit Installation44 Questions
Exam 14: Branch-Circuit Installation47 Questions
Exam 15: Special Residential Wiring Situations49 Questions
Exam 16: Video, Voice, and Data Wiring Installation52 Questions
Exam 17: Lighting Fixture Installation52 Questions
Exam 18: Device Installation46 Questions
Exam 19: Service Panel Trim-Out42 Questions
Exam 20: Checking Out and Troubleshooting Electrical Wiring Systems41 Questions
Exam 21: Green Wiring Practices32 Questions
Exam 22: Photovoltaic Pv System Installation44 Questions
Select questions type
At kitchen countertops, receptacle outlets must be installed so that no point along the wall line is more than __________ feet, measured horizontally, from a receptacle outlet in that space.
(Multiple Choice)
4.8/5
(41)
An electrician is testing a circuit where a single-pole switch controls an LED lighting fixture in a bedroom.When the single-pole switch is toggled ON, the lighting fixture does not come on.Which of the following items could not be a cause for this?
(Multiple Choice)
4.7/5
(37)
GFCI protection is not required for 125 volt, 15- or 20-ampere receptacles located __________.
(Multiple Choice)
4.8/5
(33)
A(n) _________________________ is an unintended low-resistance path in an electrical circuit through which some current flows to ground using a pathway other than the intended pathway.
(Essay)
4.9/5
(38)
Type NM cable must be secured no more than ____________________ inches from each single-gang nonmetallic device box.
(Essay)
4.9/5
(54)
When testing a "live" 120-volt receptacle using a voltage tester, you should get a 120-volt reading when measuring from the grounded conductor connection (long slot) to the grounding conductor connection (U-shaped slot).
(True/False)
4.8/5
(32)
When the white grounded circuit conductor is connected to the silver screw on a receptacle and the "hot" ungrounded conductor is connected to the brass screw on the receptacle, you have proper receptacle __________.
(Multiple Choice)
4.7/5
(41)
In the NEC, Article __________ contains requirements for grounding and bonding residential electrical systems.
(Multiple Choice)
4.8/5
(43)
The minimum size of service disconnect for a single-family dwelling unit permitted by the NEC is __________ amperes.
(Multiple Choice)
4.8/5
(37)
An electrician is testing a 20-ampere, 125-volt duplex receptacle with a voltage tester.The tester indicates 120 volts between the ungrounded slot and the grounded slot.The tester also indicates 0 volts between the ungrounded slot and the grounding slot.The likely cause is __________.
(Multiple Choice)
4.9/5
(34)
Which of the following is not a NEC requirement for minimum clearance of a lighting fixture from the storage space in clothes closets?
(Multiple Choice)
4.8/5
(32)
All branch circuits supplying 125-volt, 15- and 20-ampere outlets and devices in residential kitchens, family rooms, living rooms, dining rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, laundry areas, or similar rooms must be protected by a(n) __________
(Multiple Choice)
4.8/5
(46)
An electrician tests a 30-ampere, 250-volt dryer receptacle with a voltage tester.The tester indicates 120 volts between the X and Y slots.The tester also indicates 240 volts between the X and W slots.The tester also indicates 0 volts between the Y and the grounding slot.The likely cause is __________.
(Multiple Choice)
4.8/5
(39)
When testing a "live" 120-volt receptacle using a voltage tester, you should get a 120-volt reading when measuring from the ungrounded conductor connection (short slot) to the grounding conductor connection (U-shaped slot).
(True/False)
4.9/5
(32)
The minimum length of free conductor at all boxes must be at least __________ inches.
(Multiple Choice)
4.8/5
(37)
According to the NEC, all work spaces must be provided with illumination.
(True/False)
4.9/5
(32)
Residential electrical systems may be grounded using only the metal water pipe system and do not need a supplemental grounding electrode.
(True/False)
4.8/5
(40)
Receptacle outlets in habitable rooms must be installed so that no point measured horizontally along the floor line in any wall space in more than __________ feet from a receptacle outlet.
(Multiple Choice)
4.9/5
(42)
In residential applications, Type NM cable is permitted to pass through environmental air handling spaces perpendicular to the long dimension of the space.
(True/False)
4.9/5
(29)