A multiple receptacle has more than __________ contact device(s) on the same yoke.

(Multiple Choice)
4.7/5
(41)

What do the letters "TVSS" stand for?

(Essay)
4.8/5
(39)

When more than one grounded conductor enters a device box, a wiring practice to use so that only one conductor gets connected to the silver terminal screw is to use a(n) ____________________.

(Essay)
4.9/5
(34)

All metal device boxes need to have the circuit equipment-grounding conductor(s) connected to it with a 10-32 green grounding screw.

(True/False)
4.9/5
(35)

Explain how metal faceplates are grounded if nonmetallic device boxes are used.

(Essay)
4.8/5
(30)

Explain why it is recommended to install receptacles with the grounding slot up.

(Essay)
4.8/5
(39)

The proper NEMA designation for a 15-ampere, 125-volt grounding-type receptacle is __________.

(Multiple Choice)
4.8/5
(31)

In all areas specified in Section 210.52, all nonlocking type 125- and 250-volt, 15- and 20-ampere receptacles must be tamper-resistant.(General Rule)

(True/False)
4.7/5
(36)

A TVSS device works by __________ the high-surge voltage to a level that a piece of equipment like a computer can withstand.

(Multiple Choice)
4.8/5
(38)

A(n) ____________________ switch is used to control a 240-volt load from one location.

(Essay)
4.9/5
(40)

An equipment-grounding conductor may not be __________.

(Multiple Choice)
4.7/5
(33)

The most common receptacle type used in residential wiring is the single receptacle.

(True/False)
4.8/5
(31)

Many of the appliances used in today's homes contain sensitive electronic circuitry, circuit boards, or microprocessors and these components are susceptible to transient voltages, also known as __________ or voltage spikes.

(Multiple Choice)
4.8/5
(39)

Which of the following conductors are permitted to be used for the push-in method of attaching conductors to a device?

(Multiple Choice)
4.9/5
(31)

The preferred method for connecting a circuit conductor to a device is to form a __________ in the wire, put it under a terminal screw, and tighten the screw properly.

(Multiple Choice)
4.7/5
(41)

To GFCI-protect receptacles that are downstream from a GFCI receptacle, the wiring going to those receptacles is connected to the ____________________ terminals on a feed-through GFCI receptacle.

(Essay)
4.8/5
(29)

Explain what can be done during the rough-in phase to make switch installation easier in the finish phase of the wiring process.

(Essay)
4.8/5
(34)

Describe different strategies that electricians use to properly position a duplex receptacle into a device box.

(Essay)
4.9/5
(42)

Section 404.10(B) specifies that screws used for attaching a switch to an electrical box must be sheet metal screws with a thread that matches the thread gage or size of the screw holes in the box.

(True/False)
4.8/5
(43)

Section 406.5 specifies that screws used for attaching a receptacle to an electrical box must be machine screws with 32 threads per inch or be the type supplied by a __________ receptacle.