Exam 8: Feeders
Exam 1: Commercial Building Plans and Specifications20 Questions
Exam 2: Reading Electrical Working Drawings- Entry Level20 Questions
Exam 3: Calculating the Electrical Load20 Questions
Exam 4: Branch Circuits20 Questions
Exam 5: Switches and Receptacles20 Questions
Exam 6: Wiring Methods20 Questions
Exam 7: Motor and Appliance Circuits20 Questions
Exam 8: Feeders20 Questions
Exam 9: Special Systems20 Questions
Exam 10: Working Drawings- Upper Level20 Questions
Exam 11: Special Circuits Owners Circuits20 Questions
Exam 12: Panelboard Selection and Installation20 Questions
Exam 13: The Electric Service20 Questions
Exam 14: Lamps and Ballasts for Lighting20 Questions
Exam 15: Luminaires20 Questions
Exam 16: Emergency, Legally Required Sstandby, and Optional Standby Power Systems20 Questions
Exam 17: Overcurrent Protection: Fuses and Circuit Breakers20 Questions
Exam 18: Short-Circuit Calculations and Coordination of Overcurrent Protective Devices20 Questions
Exam 19: Equipment and Conductor Short-Circuit Protection20 Questions
Exam 20: Low-Voltage Remote-Control20 Questions
Exam 21: The Cooling System20 Questions
Exam 22: Commercial Utility Interactive Photovoltaic Systems20 Questions
Select questions type
If the selected OCPD has a rating greater than 100-amperes, the conductors to be installed shall be selected from either the 75 degrees Celsius or degrees Celsius column of NEC Table 310.15(B)(16).
Free
(Multiple Choice)
4.8/5
(37)
Correct Answer:
B
Feeders are the part of the electrical system that connects the branch-circuit to the electrical service equipment.
Free
(Multiple Choice)
4.7/5
(34)
Correct Answer:
D
To determine a reasonable minimum size for a neutral conductor, two types of loads must be considered- .
Free
(Multiple Choice)
4.7/5
(37)
Correct Answer:
C
On a 3-phase, 4-wire, wye system, reduction is allowed for nonlinear loads.
(Multiple Choice)
4.8/5
(31)
Often the load is such that parallel conductors should be considered.This usually occurs with loads over amperes.
(Multiple Choice)
4.7/5
(34)
To get accurate current readings where harmonics are involved, ammeters referred to as " " must be used.
(Multiple Choice)
4.8/5
(34)
NEC 310.10(H) sets forth the requirements for installing conductors.These requirements are intended to ensure the conductors will share the current equally to prevent overloading individual conductors.
(Multiple Choice)
4.8/5
(38)
If the ampacity of a feeder does not match a standard OCPD rating, then be used.
(Multiple Choice)
4.8/5
(40)
What wire and cable options do you have for combating excessive neutral current?
(Essay)
4.8/5
(43)
The ampacity is the allowable ampacity multiplied by the factor.
(Multiple Choice)
4.9/5
(36)
For installations where the nonlinear load is huge, most consulting engineers will specify -rated transformers.
(Multiple Choice)
4.8/5
(41)
What three circuit parameters must be known before feeder component selection can begin?
(Essay)
4.8/5
(30)
wire is seldom used in branch circuits, but because of weight and cost factors, it is frequently selected for feeders and services.
(Multiple Choice)
4.8/5
(38)
In the United States, Hz is standard or the fundamental frequency.
(Multiple Choice)
4.8/5
(35)
When sizing feeder conductors, noncoincident loads (loads unlikely to be operated simultaneously such as the air-conditioning and the heating) need be included.
(Multiple Choice)
4.9/5
(35)
Currents of the 3rd harmonic and odd multiples of the 3rd harmonic (9th, 15th, 21st, etc.) add together in the common neutral conductor of a 3-phase system, instead of canceling each other.These odd multiples are referred to as ____.
(Multiple Choice)
4.9/5
(36)
What are the three conditions of failure that may occur with a 3-phase, 4-wire wye system?
(Essay)
4.8/5
(42)
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)