Exam 14: Ultrasound Equipment Quality Assurance
Exam 1: Introduction to Quality Management10 Questions
Exam 2: Quality Management Tools and Procedures10 Questions
Exam 3: Filmscreen Image Receptors, Darkrooms, and Viewing Conditions15 Questions
Exam 4: Film Processing10 Questions
Exam 5: Processor Quality Control10 Questions
Exam 6: Silver Recovery10 Questions
Exam 7: Quality Control of X-Ray Generators and Ancillary Radiographic Equipment20 Questions
Exam 8: Quality Control of Fluoroscopic Equipment10 Questions
Exam 9: Digital and Advanced Imaging Equipment10 Questions
Exam 10: Outcomes Assessment of Radiographic Images10 Questions
Exam 11: Mammographic Quality Standards10 Questions
Exam 12: Quality Control in Computed Tomography10 Questions
Exam 13: Quality Control for Magnetic Resonance Imaging Equipment10 Questions
Exam 14: Ultrasound Equipment Quality Assurance10 Questions
Exam 15: Quality Assurance in Nuclear Medicine10 Questions
Select questions type
Maximum depth of visualization tests are performed using _____ receiver gain and _____ transmit power.
Free
(Multiple Choice)
4.8/5
(37)
Correct Answer:
C
The maximum depth of visualization can indicate changes in
Free
(Multiple Choice)
4.8/5
(28)
Correct Answer:
D
A scan is done of a uniform section in a phantom, and a vertical shadow emanates from a position on the image corresponding to the transducer surface.This is likely caused by
Free
(Multiple Choice)
4.8/5
(42)
Correct Answer:
D
On the viewing monitor of a scanner, a sonographer counts 16 shades of gray in the gray-bar pattern.The hard-copy B-mode image displays only the 13 brightest gray bars.This should be interpreted as
(Multiple Choice)
4.8/5
(32)
A measurement comparing the actual separation between two reflectors placed at different positions along the beam axis with the separation indicated on the calipers is a test of
(Multiple Choice)
4.9/5
(36)
For which of the following tests would it be acceptable for the results to vary with the transducer frequency?
(Multiple Choice)
4.9/5
(34)
A measure of the minimum spacing along the beam axis that still allows two reflectors to be identified is called the
(Multiple Choice)
4.8/5
(21)
For the measurement described in question 7, the digital caliper cursors should be placed at the
(Multiple Choice)
4.8/5
(39)
Suppose that the maximum depth of visualization using a 3.5-MHz transducer is 14.2 cm.On the previous two tests, 3 months and 6 months earlier, it was 14.4 and 14.1 cm, respectively.These variations should be interpreted as
(Multiple Choice)
4.8/5
(36)
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)