The flat-panel TFT digital detector uses complex and sophisticated electronic circuitry to read out the electrical charges produced and stored in the matrix array.
Free
(True/False)
4.8/5
(33)
Correct Answer:
True
The flat-panel TFT digital detector is designed as a matrix of detector elements, each of which can be regarded as a(n) ____________________.
Free
(Short Answer)
5.0/5
(34)
Correct Answer:
pixel
At ____ kV, efficiencies are 37% for a-Se and 52% for CsI.
Free
(Multiple Choice)
4.9/5
(45)
Correct Answer:
C
Which of the following images is obtained initially from the detector and contains artifacts due to the bad detector elements?
(Multiple Choice)
4.7/5
(31)
Which of the following plays a role in image display optimization?
(Multiple Choice)
5.0/5
(31)
Which layer used in the indirect flat-panel digital detector is usually either cesium iodide (CsI) or gradolinium oxysulfide (Gd₂O₂S)?
(Multiple Choice)
4.7/5
(36)
Too much edge enhancement produces image noise and creates ____.
(Multiple Choice)
4.7/5
(39)
Flaws in the various components that make up a panel can lead to image lag.
(True/False)
4.9/5
(34)
Image processing is not intended to correct poor images due to routine errors that are made during image ____________________.
(Short Answer)
4.9/5
(45)
The narrower the LSF, the better the ____________________ resolution.
(Short Answer)
4.8/5
(35)
The ____________________ technology was developed as a dedicated system specifically for imaging the chest.
(Short Answer)
4.9/5
(27)
Problems arising as a result of image ____________________ may also be related to the differences in the acquisition workstation and the higher-quality PACS workstation used by the radiologist.
(Short Answer)
4.9/5
(34)
Flat-panel detectors can be used in portable radiography applications and in applications involving ____________________.
(Short Answer)
4.9/5
(44)
A higher MTF value at ____________________ spatial frequencies means that the detector provides better contrast resolution.
(Short Answer)
4.8/5
(28)
Which concept examines the response of the image receptor (screen-film detector or digital detector) to the radiation falling upon it?
(Multiple Choice)
4.8/5
(37)
Which of the following describes the ability of the imaging system to resolve fine details present in an object?
(Multiple Choice)
4.9/5
(32)
Which of the following reduces the output image from the scintillator phosphor to the size of the CCD array?
(Multiple Choice)
4.9/5
(34)
The raw digital data from a detector has a high image contrast simply because of the wide exposure latitude of the digital detector.
(True/False)
4.8/5
(27)
While the low frequencies contain fine details of the image, high frequencies contain the contrast information in the image.
(True/False)
4.7/5
(33)
Which of the following addresses the appearance of the image displayed on a monitor for viewing and interpretation by a radiologist?
(Multiple Choice)
4.9/5
(22)