Exam 27: Wave Form Analysis
Exam 1: Basics of Asepsis28 Questions
Exam 2: Basic Patient Assessment: Vital Signs and Breath Sounds28 Questions
Exam 3: Advanced Patient Assessment: Inspection, Palpation, and Percussion28 Questions
Exam 4: Radiologic Assessment28 Questions
Exam 5: Pulmonary Function Testing28 Questions
Exam 6: Electrocardiography28 Questions
Exam 7: Phlebotomy28 Questions
Exam 8: Arterial Blood Gas Sampling28 Questions
Exam 9: Hemodynamic Monitoring28 Questions
Exam 10: Noninvasive Monitoring28 Questions
Exam 11: Documentation and Goals Assessment27 Questions
Exam 12: Oxygen Supply Systems28 Questions
Exam 13: Oxygen Administration33 Questions
Exam 14: Introduction to Respiratory Care Pharmacology28 Questions
Exam 15: Humidity and Aerosol Therapy28 Questions
Exam 16: Bronchial Hygiene Therapy28 Questions
Exam 17: Hyperinflation Therapy32 Questions
Exam 18: Bronchoscopy Assisting28 Questions
Exam 19: Equipment Processing and Surveillance28 Questions
Exam 20: Emergency Airway Management34 Questions
Exam 21: Artificial Airway Care28 Questions
Exam 22: Chest Tubes31 Questions
Exam 23: Insertion and Maintenance of Intravenous Lines28 Questions
Exam 24: Noninvasive Positive-Pressure Ventilation29 Questions
Exam 25: Continuous Mechanical Ventilation34 Questions
Exam 26: Advanced Modes of Mechanical Ventilation33 Questions
Exam 27: Wave Form Analysis30 Questions
Exam 28: Weaning and Discontinuance of Mechanical Ventilation30 Questions
Exam 29: Neonatal Mechanical Ventilation35 Questions
Select questions type
Which of the following is true of the flow-volume loop?
I.Flow is plotted on the vertical axis.
II.It is commonly used in PF spirometry evaluation.
III.It is done only after bronchodilator administration.
Free
(Multiple Choice)
4.8/5
(40)
Correct Answer:
B
You have just place a patient with early ARDS onto a mechanical ventilator.Using ventilator graphics how will you monitor the patient's changing lung compliance?
Free
(Essay)
4.8/5
(37)
Correct Answer:
Changes in compliance may be assessed using the pressure-volume graphical display.By assessing the slope of the loop,changes in compliance may be determined.Be sure to save or print out a pressure volume loop to compare with subsequent loops.A non-graphic method is to determine static compliance measurements but often images are easier to understand.
If the volume wave form does not reach zero on exhalation,the practitioner can determine which of the following?
Free
(Multiple Choice)
4.8/5
(42)
Correct Answer:
A
Positive end expiratory pressure is identified on a pressure-time display by _______________
(Multiple Choice)
4.7/5
(30)
Combinations of ventilator wave forms can indicate __________________
(Multiple Choice)
4.7/5
(38)
Which of the following wave form would be most useful in assessing lung compliance?
(Multiple Choice)
4.8/5
(41)
The respiratory care practitioner wants to check the airway resistance with an asthmatic patient on a ventilator.She can check airway resistance by which of the following?
(Multiple Choice)
4.9/5
(42)
Wave form graphically displays which of the following?
I.Arterial blood gas values
II.Gas flowrates
III.Inspiratory and expiratory volumes
IV.Airway pressures
(Multiple Choice)
4.8/5
(37)
The wave form variables of flow,volume and pressure are most often plotted against ______________
(Multiple Choice)
4.8/5
(39)
As the respiratory care practitioner assigned to a ventilator patient,how would you use ventilator graphics to identify patient effort?
(Essay)
4.9/5
(29)
A breath that rises and then remains at a specific cmH₂O pressure for varying lengths of inspiratory is which type of breath?
(Multiple Choice)
4.8/5
(36)
A mechanical breath that rises and then remains at the same cmH₂O pressure for the same length of time is which type of mechanical breath?
(Multiple Choice)
4.9/5
(40)
The practitioner states to the nurse that she is concerned about "beaking." The practitioner is referring to
(Multiple Choice)
4.9/5
(32)
An asthmatic patient has been placed on a mechanical ventilator.The ventilating pressures have increased and wheezes are heard on auscultation over both lung fields.How can the practitioner assess improvement from aerosolized bronchodilator therapy?
(Essay)
4.8/5
(39)
A steeper slope of the pressure versus volume loop indicates ________________
(Multiple Choice)
4.8/5
(36)
Which of the following wave forms would be most useful in detecting changes in airway resistance especially after delivery of a bronchodilator?
(Multiple Choice)
4.9/5
(43)
The respiratory care practitioner wants to use the graphic display to determine the ventilator's tidal volume.Which of the following should he do?
(Multiple Choice)
4.8/5
(37)
You are concerned that the ventilator patient you are assessing may have autoPEEP.How would you use ventilator graphics to identify whether or not this problem exists?
(Essay)
4.9/5
(32)
The respiratory care practitioner determines that a patient has increased airway resistance.How was this identified?
(Multiple Choice)
4.8/5
(44)
Showing 1 - 20 of 30
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)