Exam 1: Mathematics and Statistics
Exam 1: Mathematics and Statistics42 Questions
Exam 2: Cell and Molecular Biology15 Questions
Exam 3: Chemistry/biochemistry24 Questions
Exam 4: Radio-Chemistry/Radio-Pharmacology25 Questions
Exam 5: Radiation Safety in Nuclear Medicine20 Questions
Exam 6: Patient Care30 Questions
Exam 7: Department Administration19 Questions
Exam 8: Clinical Research20 Questions
Exam 9: Health Informatics in Imaging15 Questions
Exam 10: Physics of Nuclear Medicine33 Questions
Exam 11: Instrumentation39 Questions
Exam 12: CT Physics and Instrumentation25 Questions
Exam 13: Pet Instrumentation29 Questions
Exam 14: Principles of Magnetic Resonance Imaging22 Questions
Exam 15: Clinical Petct in Oncology17 Questions
Exam 16: Central Nervous System16 Questions
Exam 17: Endocrine System17 Questions
Exam 18: Respiratory System30 Questions
Exam 19: Cardiovascular System29 Questions
Exam 20: Gastrointestinal System30 Questions
Exam 21: Genitourinary System25 Questions
Exam 22: Skeletal System15 Questions
Exam 23: Inflammatory Tumoroncology Imaging and Therapy26 Questions
Exam 24: Hematopoietic System20 Questions
Select questions type
A sample shows a count rate of 36,000 cpm during a 3-minute counting period.Express this as the count rate ± standard deviation.
(Multiple Choice)
4.9/5
(39)
It is known that 75% of a radionuclide decays away in 12 hours.If starting with 10 mCi, how much will be left after 6 hours?
(Multiple Choice)
4.9/5
(37)
A thyroid uptake dose of 10 Ci is equal to how much radioactivity in SI units?
(Multiple Choice)
4.8/5
(39)
How many counts should be acquired into each pixel of a nuclear medicine flood image if it is desired to be 95% confident that the true count in each pixel is within 1% of the measured counts in each pixel?
(Multiple Choice)
4.9/5
(36)
What is the proper number of decimal places in the sum of (0.3) + (3.5264)?
(Multiple Choice)
4.8/5
(44)
An intensity setting of 250 on a display screen may produce a suitable image for a bar phantom with 500K counts in the acquisition.Now it is desired to change to 350K counts in the image.The intensity on the screen is known to change linearly with the intensity control setting.What intensity setting should be used for the new 350K-count image?
(Multiple Choice)
4.8/5
(39)
A 5-ml sample of a standard diluted 1:10,000 produces 27,200 counts in the well counter.A 5-ml sample of patient plasma, counted for the same time as the diluted standard sample, produces 99,100 counts.What is the plasma volume?
(Multiple Choice)
4.8/5
(43)
A radioactive source of 137Cs (t1/2= 30 y) was calibrated on October 23, 2000, to contain 10 Ci.This is used as a daily accuracy check source in the dose calibrator.Presuming the dose calibrator is working properly, what activity should the dose calibrator show on April 23, 2006?
(Multiple Choice)
4.8/5
(39)
The dose equivalent for occupational whole-body exposure is commonly limited to 50 mSv.How many rem is this?
(Multiple Choice)
4.9/5
(32)
A nuclear medicine test produces a positive test result in only 80 of the 100 patients known to be ill.Similarly, the test produces a negative test result in only 190 of the 200 patients known to be not ill.Which is correct?
(Multiple Choice)
4.8/5
(44)
The linear attenuation coefficient in lead for 99mTc gamma rays (140 keV) is 23 cm-1.What percentage of these gamma rays will be absorbed by a lead apron that contains 0.60 mm of lead?
(Multiple Choice)
4.7/5
(41)
The morning elution of the 99Mo-99mTc generator yields 850 mCi of 99mTc radioactivity in 20 ml of saline eluate.What volume should be withdrawn from the eluate vial into a patient syringe to immediately perform a 25-mCi patient scan?
(Multiple Choice)
4.9/5
(55)
Readers are encouraged to use Microsoft Excel to solve this problem.What is the slope and intercept in the regression equation for problem 31? (board score) = intercept + (slope) * (exam score)
(Multiple Choice)
4.8/5
(39)
One radiologist is known to be a lax reader compared with another radiologist who is known to be a strict reader.In comparing these radiologists, how would one expect their sensitivity and specificity to compare?
(Multiple Choice)
4.8/5
(37)
Using Table 1-9 in the book, what is the P value for the linear correlation coefficient r in question 31?
(Multiple Choice)
4.9/5
(35)
If the HVL for some radionuclide in lead is 0.30 mm, what thickness of lead shielding is necessary to reduce the radiation exposure from 8 mR/hr to 1 mR/hr?
(Multiple Choice)
4.7/5
(35)
A patient may have had a kidney function test last month that showed a kidney clearance rate of 45 milliliters per minute (ml/min).The patient returns today and has a kidney clearance rate of 60 ml/min.What is the percent increase in kidney function?
(Multiple Choice)
4.9/5
(36)
One group of 20 patients is given a drug that is thought to have an effect on kidney function, and another group of 20 patients is given a placebo (i.e., sugar pill, which is known not to have an effect on kidney function).The nuclear medicine gamma camera is used to calculate the glomerular filtration rate (GFR) in these two groups of patients.What would be the proper statistical test to use to test the hypothesis that no difference in GFR exists between these two groups of patients?
(Multiple Choice)
4.9/5
(45)
Showing 21 - 40 of 42
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)