Exam 11: Special Circuits Owners Circuits
Exam 1: Commercial Building Plans and Specifications20 Questions
Exam 2: Reading Electrical Working Drawings--Entry Level20 Questions
Exam 3: General Requirements for Conductors16 Questions
Exam 4: Branch Circuits20 Questions
Exam 5: Switches and Receptacles20 Questions
Exam 6: Wiring Methods20 Questions
Exam 7: Motor and Appliance Circuits20 Questions
Exam 8: Feeder Installation and Load Calculation22 Questions
Exam 9: Special Systems20 Questions
Exam 10: Working Drawings--Upper Level20 Questions
Exam 11: Special Circuits Owners Circuits20 Questions
Exam 12: Panelboard Selection and Installation20 Questions
Exam 13: The Electric Service and Grounding20 Questions
Exam 14: Lamps and Ballasts for Lighting20 Questions
Exam 15: Luminaires20 Questions
Exam 16: Emergency, Legally Required Standby, and Optional Standby Power Systems20 Questions
Exam 17: Overcurrent Protection: Fuses and Circuit Breakers20 Questions
Exam 18: Short-Circuit Calculations and Coordination of Overcurrent Protective Devices20 Questions
Exam 19: Equipment and Conductor Short-Circuit17 Questions
Exam 20: Low-Voltage Remote Control20 Questions
Exam 21: The Cooling System20 Questions
Exam 22: Commercial Utility-Interactive Photovoltaic Systems20 Questions
Select questions type
In the commercial building in the chapter example, what do the owner's circuits serve?
Free
(Essay)
4.8/5
(41)
Correct Answer:
In the commercial building, the owner's circuits serve:
∙the elevator equipment that has the greatest electrical demand.
∙ heating and lighting for the public restrooms, hallway, and stairways as well as the exit signs for the basement, rear entrance hallway, and the second floor hallway.
∙ loads that are to be supplied by the optional standby power system.
The photocell control device consists of a light-sensitive cell and a(n)____ that increases the signal until it is sufficient to operate a relay that controls the light.
Free
(Multiple Choice)
4.8/5
(30)
Correct Answer:
D
With an electrically heated boiler, a heat sensor plus a remote bulb is mounted so that the bulb is ____.
Free
(Multiple Choice)
4.8/5
(40)
Correct Answer:
B
The lighting circuits that are considered to be the owner's responsibility can be divided into six groups according to the method used to control the circuit, including those under ____.
(Multiple Choice)
5.0/5
(34)
In a commercial building, it is the ____ responsibility to provide power for the elevator; illumination for the public areas such as hallways, stairways, and public toilet rooms; and heat for the common areas of the building.
(Multiple Choice)
4.8/5
(35)
One type of sump pump that is available commercially has a start-stop operation due to water pressure against a ____, which in turn pushes against a small integral switch within the submersible pump.
(Multiple Choice)
5.0/5
(38)
With a "____" elevator, the entire elevator lifting mechanism is located in the elevator shaft either on the elevator or on the wall.
(Multiple Choice)
4.7/5
(33)
The sump pump motor is protected by a manual motor starter and is controlled by a ____ switch.
(Multiple Choice)
4.8/5
(44)
The ____ is(are)an example(s)of equipment that is operated by an automatic control system.
(Multiple Choice)
4.9/5
(32)
In the boiler heating circuit in the chapter example, the main lugs connect to two ____-kcmil-per-phase conductors run to an 800-ampere switch.
(Multiple Choice)
4.9/5
(36)
The circuit to the hot-water circulating pump in the chapter example will be supplied from the ____ so that the water will continue to circulate if the utility power fails.
(Multiple Choice)
5.0/5
(33)
The building's occupants will each have a(n)____ located within their particular area.
(Multiple Choice)
4.8/5
(33)
The luminaires installed for the stairway to the second floor and hallways of the commercial building example in this chapter are ____ when the building is occupied because those spaces have no windows.
(Multiple Choice)
4.9/5
(40)
In the commercial building example of this chapter, the owner may choose to install an electrically heated ____ to supply heat to all areas.
(Multiple Choice)
4.9/5
(32)
Describe the wiring for electric elevators, including the roles of the electrical contractor and the elevator contractor.
(Essay)
4.8/5
(41)
On lighting controlled by timers, an ____ feature is extremely desirable because it provides sunset ON and sunrise OFF that change automatically day by day as the sunrise and sunset times change every day.
(Multiple Choice)
4.9/5
(34)
The heat sensor in an electrically heated boiler is adjusted so that it closes when the outside temperature falls below a set point, usually ____ degrees Fahrenheit.
(Multiple Choice)
4.9/5
(36)
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)