Exam 19: Testing, Adjusting and Balancing
Exam 1: Matter, Energy, and Heat Basics27 Questions
Exam 2: The Refrigeration Process30 Questions
Exam 3: General Safety Practices30 Questions
Exam 4: Refrigerant Management26 Questions
Exam 5: Hand Tools26 Questions
Exam 6: Tubing and Piping Tools28 Questions
Exam 7: Specialized Hvacr Tools43 Questions
Exam 8: System Location16 Questions
Exam 9: Air-Distribution Systems25 Questions
Exam 10: System Connections28 Questions
Exam 11: Leak Testing25 Questions
Exam 12: System Evacuation26 Questions
Exam 13: System Startup and Charging21 Questions
Exam 14: Electricity Fundamentals27 Questions
Exam 15: Electric Motors and Starting Components30 Questions
Exam 16: Electronic Controls26 Questions
Exam 17: Wiring Diagrams14 Questions
Exam 18: Electric Codes34 Questions
Exam 19: Testing, Adjusting and Balancing26 Questions
Exam 20: Indoor Air Quality30 Questions
Exam 21: Mechanical Troubleshooting26 Questions
Exam 22: Electrical Troubleshooting26 Questions
Exam 23: Electric Heat26 Questions
Exam 24: Gas Heat31 Questions
Exam 25: Oil Heat29 Questions
Exam 26: Hydronic Heat29 Questions
Exam 27: Heat Pumps25 Questions
Select questions type
Stepwise balancing involves stepping down the airflow to the outlets with the greatest amount of excess air.
Free
(True/False)
4.7/5
(36)
Correct Answer:
True
A duct system is pressurized by three pressures. Match each type of pressure to its correct definition.
Premises:
the pressure that results from the speed and the weight of the air
Responses:
total pressure
static pressure
velocity pressure
Correct Answer:
Premises:
Responses:
Free
(Matching)
4.8/5
(37)
Correct Answer:
The air pathway with the greatest resistance is often the __________.
Free
(Multiple Choice)
4.9/5
(34)
Correct Answer:
A
A duct system is pressurized by three pressures. Match each type of pressure to its correct definition.
Premises:
the sum of the static and velocity pressures
Responses:
velocity pressure
total pressure
static pressure
Correct Answer:
Premises:
Responses:
(Matching)
4.9/5
(46)
TAB work for residential systems involves measuring airflow rates and adjusting the volume control devices and/or blower speeds to maintain the desired airflow in the air distribution system. For the most part, the acceptable air volume in the air distribution system is within __________ of the desired airflow rate.
(Multiple Choice)
5.0/5
(31)
In the domestic environment, TAB work is typically performed on the hot water heating system.
(True/False)
4.7/5
(35)
__________ is the process of matching the actual fluid flow rates to the desired fluid flow rates within an acceptable range.
(Multiple Choice)
4.9/5
(52)
Describe the two most popular ways to measure the air volume supplied by the system blower.
(Essay)
4.9/5
(39)
The main concern of proportional balancing is to have the airflow at any given outlet at the same percentage of design airflow as any other outlet in the system.
(True/False)
4.8/5
(47)
Before the TAB work can begin, it is important to know what the __________ for the system are.
(Short Answer)
4.8/5
(38)
A system is said to be balanced when two conditions are met. List these two conditions.
(Essay)
4.9/5
(36)
Testing and balancing is the process of determining if __________.
(Short Answer)
5.0/5
(38)
The three elements of TAB work are __________, __________, and __________.
(Short Answer)
4.9/5
(37)
Improper system sizing, airflow and charging result in a significant reduction in capacity that can be as great as __________.
(Multiple Choice)
4.9/5
(37)
A duct system is pressurized by three pressures. Match each type of pressure to its correct definition.
Premises:
the pressure that pushes against the sides of the duct sections
Responses:
velocity pressure
static pressure
total pressure
Correct Answer:
Premises:
Responses:
(Matching)
4.8/5
(37)
__________ is the process of varying fluid flow by changing the settings on fluid flow controls such as valves, dampers, and blowers.
(Multiple Choice)
5.0/5
(35)
Match each tool with its purpose.
Premises:
measures circuit currents
Responses:
pitot tube
ammeter
u-tube manometer
Correct Answer:
Premises:
Responses:
(Matching)
4.8/5
(34)
By initiating the TAB process, a number of system deficiencies that might otherwise go unnoticed can be uncovered and remedied. List five such deficiencies
(Essay)
4.8/5
(37)
__________ is the process of using specialized, properly calibrated instruments to measure characteristics of fluid flow and electricity.
(Multiple Choice)
4.8/5
(40)
The first step to balancing an air distribution system is making certain that __________ is being provided by the blower.
(Short Answer)
4.8/5
(34)
Showing 1 - 20 of 26
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)