Exam 8: System Location

arrow
  • Select Tags
search iconSearch Question
  • Select Tags

To prevent prevailing wind from affecting the operation of the air conditioning system, the condensing unit should be positioned in a __________ location. __________ provide very good protection for the unit, preventing wind from blowing through it. However, they must be to __________ prevent them from blocking the unit's coil surfaces. The __________ can also create an airflow problem through the coil itself if they are pulled into the unit.

Free
(Short Answer)
4.9/5
(33)
Correct Answer:
Verified

shielded, shrubs, trimmed regularly, leaves

Lengthy duct runs will have a __________ effect on the operation of the air conditioning system.

Free
(Multiple Choice)
4.8/5
(39)
Correct Answer:
Verified

B

Which of the following is the most likely outcome if the condensing unit is not properly leveled?

Free
(Multiple Choice)
4.8/5
(36)
Correct Answer:
Verified

B

The interior surfaces of ductwork offer resistance to airflow, reducing the __________ of the air moving through it and thus the air conditioning system's operating efficiency.

(Multiple Choice)
4.9/5
(32)

When the air handler is located in the basement, a __________ is needed to move the condensate up to an overhead line..

(Multiple Choice)
4.8/5
(36)

For residential applications, the packaged air conditioning system is positioned at ground level, very close to the structure. When selecting the location for the unit a number of factors must be considered. List six of these factors.

(Essay)
4.9/5
(42)

Wherever the condenser unit is located, it should be perfectly __________. This will prevent __________on the condenser fan motor. The unit should never be set directly on the ground, as this can cause the unit to __________ and the coil to be blocked with __________. The unit should be located __________ ground level and should sit on a slab made of one of a number of materials, such as __________ or __________.

(Short Answer)
4.9/5
(38)

The condensing unit of the split air conditioning system contains a __________ and a __________, both of which generate noise that could be distracting to those around it.

(Multiple Choice)
4.9/5
(36)

__________ air handler units can be configured for right-hand or left-hand flow with only minor alterations to the position of the internal drain pan located within the unit.

(Multiple Choice)
4.8/5
(33)

In addition to removing heat from the air, the air conditioning system also __________ the air, thereby creating __________, which is the moisture removed from the air.

(Multiple Choice)
4.9/5
(43)

List six factors that must be considered when choosing the location for the indoor unit of the split air conditioning system.

(Essay)
4.8/5
(41)

Which type of air handler would be best suited for a system where the air handler is located in a basement?

(Multiple Choice)
4.9/5
(43)

When the air handler is located in an attic or overhead area, the condensate drain line should be routed to the __________ of the structure, if at all possible.

(Multiple Choice)
4.8/5
(39)

Which type of air handler would be best suited for attic installation?

(Multiple Choice)
4.8/5
(37)

One of the most important factors that will affect the success of the split air conditioner's installation is the condensing unit's __________ with respect to the indoor unit. The distance between these two pieces of equipment determines the length of the refrigerant lines that must be installed. The __________ these lines, the better.

(Short Answer)
4.8/5
(39)

List six factors that must be considered in order to establish the proper location for the condensing unit of a split residential central air conditioning system.

(Essay)
4.8/5
(35)
close modal

Filters

  • Essay(0)
  • Multiple Choice(0)
  • Short Answer(0)
  • True False(0)
  • Matching(0)