Exam 11: Scatter Control
Exam 1: Introduction to the Imaging Sciences75 Questions
Exam 2: Structure of the Atom63 Questions
Exam 3: Electromagnetic and Particulate Radiation58 Questions
Exam 4: X-Ray Circuit147 Questions
Exam 5: The X-Ray Tube108 Questions
Exam 6: X-Ray Production68 Questions
Exam 7: X-Ray Interactions With Matter63 Questions
Exam 8: Image Production66 Questions
Exam 9: Image Characteristics161 Questions
Exam 10: Radiographic Exposure Technique163 Questions
Exam 11: Scatter Control80 Questions
Exam 12: Image Receptors167 Questions
Exam 13: Automatic Exposure Control60 Questions
Exam 14: Image Intensified Fluoroscopy100 Questions
Exam 15: Additional Equipment54 Questions
Exam 16: Computed Tomography125 Questions
Select questions type
For a lateral lumbar spine,placing a lead shield on the table behind the area of exposure:
(Multiple Choice)
4.7/5
(32)
It is safe to assume that the x-ray beam field size and the light field size are exactly the same.
(True/False)
4.9/5
(47)
The type of grid that includes a channel for the IR to slide into is the:
(Multiple Choice)
4.8/5
(34)
The air gap technique is a frequently used method for reducing the amount of scatter radiation reaching the IR.
(True/False)
4.8/5
(36)
The recommended SIDs that can be used with a focused grid is the:
(Multiple Choice)
4.8/5
(39)
Decreasing collimation (opening up the field size)results in:
(Multiple Choice)
5.0/5
(35)
Focused grids are more effective than parallel grids in absorbing scatter radiation and allowing transmitted radiation to reach the IR.
(True/False)
4.8/5
(28)
When the x-ray beam is angled across the lead strips you have _________ cutoff.
(Multiple Choice)
4.8/5
(31)
Grids absorb almost all of the scatter radiation and allow all of the transmitted photons to pass through to the IR.
(True/False)
4.8/5
(39)
When using automatic collimation,collimating to the anatomy of interest is an unnecessary waste of time;the beam is already collimated.
(True/False)
4.8/5
(42)
The air gap technique reduces the amount of scatter radiation reaching the IR because:
(Multiple Choice)
4.8/5
(51)
Which of the following produces the greatest amount of scatter radiation exiting the patient?
(Multiple Choice)
4.9/5
(46)
A flat piece of lead with a hole in it that has a flange directed toward the patient is a(n):
(Multiple Choice)
4.8/5
(37)
Grids absorb scatter radiation because the scattered photons:
(Multiple Choice)
4.8/5
(42)
When the x-ray beam is not lined up with the center of the grid you have _________ cutoff.
(Multiple Choice)
4.8/5
(33)
The number of lead lines per inch or centimeter is the grid:
(Multiple Choice)
4.9/5
(36)
Anyone in the room during an exposure must wear a lead apron to absorb the scatter radiation produced in the:
(Multiple Choice)
4.7/5
(39)
Showing 41 - 60 of 80
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)