Exam 11: Scatter Control

arrow
  • Select Tags
search iconSearch Question
flashcardsStudy Flashcards
  • Select Tags

For a lateral lumbar spine,placing a lead shield on the table behind the area of exposure:

(Multiple Choice)
4.7/5
(32)

It is safe to assume that the x-ray beam field size and the light field size are exactly the same.

(True/False)
4.9/5
(47)

Grid cutoff results in:

(Multiple Choice)
4.7/5
(40)

The type of grid that includes a channel for the IR to slide into is the:

(Multiple Choice)
4.8/5
(34)

The air gap technique is a frequently used method for reducing the amount of scatter radiation reaching the IR.

(True/False)
4.8/5
(36)

The Moiré effect is also known as the _________ pattern.

(Multiple Choice)
4.9/5
(27)

The recommended SIDs that can be used with a focused grid is the:

(Multiple Choice)
4.8/5
(39)

Decreasing collimation (opening up the field size)results in:

(Multiple Choice)
5.0/5
(35)

Focused grids are more effective than parallel grids in absorbing scatter radiation and allowing transmitted radiation to reach the IR.

(True/False)
4.8/5
(28)

When the x-ray beam is angled across the lead strips you have _________ cutoff.

(Multiple Choice)
4.8/5
(31)

Grids absorb almost all of the scatter radiation and allow all of the transmitted photons to pass through to the IR.

(True/False)
4.8/5
(39)

When using automatic collimation,collimating to the anatomy of interest is an unnecessary waste of time;the beam is already collimated.

(True/False)
4.8/5
(42)

The volume of tissue irradiated is determined by:

(Multiple Choice)
4.7/5
(37)

The air gap technique reduces the amount of scatter radiation reaching the IR because:

(Multiple Choice)
4.8/5
(51)

Which of the following produces the greatest amount of scatter radiation exiting the patient?

(Multiple Choice)
4.9/5
(46)

A flat piece of lead with a hole in it that has a flange directed toward the patient is a(n):

(Multiple Choice)
4.8/5
(37)

Grids absorb scatter radiation because the scattered photons:

(Multiple Choice)
4.8/5
(42)

When the x-ray beam is not lined up with the center of the grid you have _________ cutoff.

(Multiple Choice)
4.8/5
(33)

The number of lead lines per inch or centimeter is the grid:

(Multiple Choice)
4.9/5
(36)

Anyone in the room during an exposure must wear a lead apron to absorb the scatter radiation produced in the:

(Multiple Choice)
4.7/5
(39)
Showing 41 - 60 of 80
close modal

Filters

  • Essay(0)
  • Multiple Choice(0)
  • Short Answer(0)
  • True False(0)
  • Matching(0)