Exam 11: Scatter Control
Exam 1: Introduction to the Imaging Sciences75 Questions
Exam 2: Structure of the Atom63 Questions
Exam 3: Electromagnetic and Particulate Radiation58 Questions
Exam 4: X-Ray Circuit147 Questions
Exam 5: The X-Ray Tube108 Questions
Exam 6: X-Ray Production68 Questions
Exam 7: X-Ray Interactions With Matter63 Questions
Exam 8: Image Production66 Questions
Exam 9: Image Characteristics161 Questions
Exam 10: Radiographic Exposure Technique163 Questions
Exam 11: Scatter Control80 Questions
Exam 12: Image Receptors167 Questions
Exam 13: Automatic Exposure Control60 Questions
Exam 14: Image Intensified Fluoroscopy100 Questions
Exam 15: Additional Equipment54 Questions
Exam 16: Computed Tomography125 Questions
Select questions type
If a shoulder examination is done using an 8:1 ratio grid and 12 mAs,how much mAs should be used if the examination must be done tabletop (no grid)?
(Multiple Choice)
4.8/5
(35)
The location in space where all the lines extended from the lead strips meet is the:
(Multiple Choice)
4.8/5
(42)
To compensate for some of the loss of recorded detail due to the large OID used with the air gap technique,the ________ should be increased as well.
(Multiple Choice)
4.7/5
(42)
The most effective and often used radiographic beam-restriction device is the:
(Multiple Choice)
4.8/5
(38)
If a tabletop exposure (no grid)of a humerus requires 2.5 mAs,how much mAs is needed if a 12:1 ratio grid is added?
(Multiple Choice)
4.9/5
(30)
Which of the following is the formula used to determine grid ratio?
(Multiple Choice)
4.8/5
(49)
The cutoff that appears as a strip of appropriate density in the middle of the image and a significant loss of density on both sides is:
(Multiple Choice)
4.9/5
(50)
What is the grid ratio if the grid frequency is 100 lines/inch,and the lead strips are 1.8 mm high and 0.3 mm apart?
(Multiple Choice)
4.8/5
(36)
Grids are typically only used when the part measures more than ________ cm and ______ kVp is needed for the examination.
(Multiple Choice)
5.0/5
(38)
Absorption of transmitted photons by a grid caused by misalignment is:
(Multiple Choice)
4.9/5
(41)
Beam-restricting devices are located just above the tube housing.
(True/False)
4.8/5
(48)
The beam-restriction device that includes a visible light projecting the x-ray field size onto the patient is the:
(Multiple Choice)
4.9/5
(33)
If 22 mAs and a 5:1 grid results in an excellent radiograph,how much mAs is needed with a 12:1 grid?
(Multiple Choice)
4.9/5
(44)
The most easily adjusted radiographic beam-restricting device is the:
(Multiple Choice)
4.8/5
(32)
For radiographic procedures,scatter radiation is primarily the result of:
(Multiple Choice)
4.8/5
(44)
As compared with lower kVp exposures,when using high kVp the energy of the scattered photon is:
(Multiple Choice)
4.7/5
(31)
Restriction of the primary beam to the anatomy of interest:
(Multiple Choice)
4.9/5
(33)
A grid with lead strips that run parallel to each other is a:
(Multiple Choice)
4.9/5
(39)
Showing 61 - 80 of 80
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)