Exam 11: Scatter Control

arrow
  • Select Tags
search iconSearch Question
flashcardsStudy Flashcards
  • Select Tags

If a shoulder examination is done using an 8:1 ratio grid and 12 mAs,how much mAs should be used if the examination must be done tabletop (no grid)?

(Multiple Choice)
4.8/5
(35)

The location in space where all the lines extended from the lead strips meet is the:

(Multiple Choice)
4.8/5
(42)

To compensate for some of the loss of recorded detail due to the large OID used with the air gap technique,the ________ should be increased as well.

(Multiple Choice)
4.7/5
(42)

The most effective and often used radiographic beam-restriction device is the:

(Multiple Choice)
4.8/5
(38)

If a tabletop exposure (no grid)of a humerus requires 2.5 mAs,how much mAs is needed if a 12:1 ratio grid is added?

(Multiple Choice)
4.9/5
(30)

The field shape produced by a collimator is:

(Multiple Choice)
4.9/5
(39)

Which of the following is the formula used to determine grid ratio?

(Multiple Choice)
4.8/5
(49)

The unrestricted primary x-ray beam is:

(Multiple Choice)
4.8/5
(34)

The cutoff that appears as a strip of appropriate density in the middle of the image and a significant loss of density on both sides is:

(Multiple Choice)
4.9/5
(50)

What is the grid ratio if the grid frequency is 100 lines/inch,and the lead strips are 1.8 mm high and 0.3 mm apart?

(Multiple Choice)
4.8/5
(36)

Grids are typically only used when the part measures more than ________ cm and ______ kVp is needed for the examination.

(Multiple Choice)
5.0/5
(38)

Absorption of transmitted photons by a grid caused by misalignment is:

(Multiple Choice)
4.9/5
(41)

Beam-restricting devices are located just above the tube housing.

(True/False)
4.8/5
(48)

The beam-restriction device that includes a visible light projecting the x-ray field size onto the patient is the:

(Multiple Choice)
4.9/5
(33)

If 22 mAs and a 5:1 grid results in an excellent radiograph,how much mAs is needed with a 12:1 grid?

(Multiple Choice)
4.9/5
(44)

The most easily adjusted radiographic beam-restricting device is the:

(Multiple Choice)
4.8/5
(32)

For radiographic procedures,scatter radiation is primarily the result of:

(Multiple Choice)
4.8/5
(44)

As compared with lower kVp exposures,when using high kVp the energy of the scattered photon is:

(Multiple Choice)
4.7/5
(31)

Restriction of the primary beam to the anatomy of interest:

(Multiple Choice)
4.9/5
(33)

A grid with lead strips that run parallel to each other is a:

(Multiple Choice)
4.9/5
(39)
Showing 61 - 80 of 80
close modal

Filters

  • Essay(0)
  • Multiple Choice(0)
  • Short Answer(0)
  • True False(0)
  • Matching(0)