Exam 41: Computed Tomography
Exam 1: Basic Mathematics18 Questions
Exam 2: Radiation Concepts45 Questions
Exam 3: Electricity49 Questions
Exam 4: Electromagnetism46 Questions
Exam 5: X-Ray Equipment47 Questions
Exam 6: The X-Ray Tube50 Questions
Exam 7: X-Ray Production26 Questions
Exam 8: Radiation Protection Concepts and Equipment36 Questions
Exam 9: Radiation Protection Procedures for Patients and Personnel36 Questions
Exam 10: Filtration38 Questions
Exam 11: The Prime Factors45 Questions
Exam 12: X-Ray Interactions41 Questions
Exam 13: Minimizing Patient Dose30 Questions
Exam 14: Vision and Perception26 Questions
Exam 15: Beam Restriction40 Questions
Exam 16: The Patient As a Beam Emitter40 Questions
Exam 17: The Pathology Problem34 Questions
Exam 18: The Grid41 Questions
Exam 19: Radiographic Film33 Questions
Exam 20: Film Processing41 Questions
Exam 21: Film Sensitometry36 Questions
Exam 22: Intensifying Screens and Film Screen Combinations43 Questions
Exam 23: Digital Radiography50 Questions
Exam 24: Picture Archiving and Communication Systems Pacs40 Questions
Exam 25: The Imaging Process26 Questions
Exam 26: Densityir Exposure50 Questions
Exam 27: Contrast38 Questions
Exam 28: Recorded Detail42 Questions
Exam 29: Distortion35 Questions
Exam 30: The Art of Image Critique27 Questions
Exam 31: Quality Management36 Questions
Exam 32: Exposure Systems and Charts39 Questions
Exam 33: Automatic Exposure Controls31 Questions
Exam 34: Exposure Conversion Problems38 Questions
Exam 35: Mobile Radiography34 Questions
Exam 36: Fluoroscopy55 Questions
Exam 37: Tomography and Digital Tomosynthesis31 Questions
Exam 38: Mammography40 Questions
Exam 39: Bone Densitometry38 Questions
Exam 40: Vascular Imaging Equipment25 Questions
Exam 41: Computed Tomography40 Questions
Exam 42: Magnetic Resonance Imaging52 Questions
Exam 43: Nuclear Medicine45 Questions
Exam 44: Radiation Therapy37 Questions
Exam 45: Diagnostic Medical Sonography48 Questions
Select questions type
If the table is moving at 10 mm/sec., and a section thickness of 8 mm is being acquired, what is the pitch?
(Short Answer)
4.8/5
(34)
If the table is moving at 5 mm/sec., and a pitch of 1.5 is being used, what is the section thickness?
(Short Answer)
4.8/5
(41)
If a pitch of 1.0 is being used with a section thickness of 8 mm, what is the proper table speed?
(Short Answer)
4.8/5
(37)
The localization image produced by the CT scanner is technically called a/an
(Multiple Choice)
5.0/5
(46)
The CT radiographer usually varies the ____ to control the primary beam.
(Multiple Choice)
4.7/5
(42)
The process of combining detector elements into various combinations in order set slice thickness is called detector
(Multiple Choice)
4.8/5
(32)
The process of modifying pixel values by a mathematical formula is called
(Multiple Choice)
4.9/5
(34)
CT scan pitch uses all of the following technical parameters EXCEPT
(Multiple Choice)
4.8/5
(37)
The ____ is how well the detectors convert incoming photons.
(Multiple Choice)
4.8/5
(38)
The primary mathematical method used in the creation of computerized medical images is the ____ transformation.
(Multiple Choice)
4.9/5
(39)
The calculation of CT numbers is based upon the calculation of
(Multiple Choice)
4.7/5
(37)
If a pitch of 0.5 is being used with a section thickness of 10 mm, what is the proper table speed?
(Short Answer)
5.0/5
(47)
Showing 21 - 40 of 40
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)