Technique charts are still needed when using AEC.
Free
(True/False)
4.7/5
(26)
Correct Answer:
True
The technique chart will provide information as to how to recognize and compensate for additive pathology.
Free
(True/False)
4.9/5
(39)
Correct Answer:
False
A variable kVp-fixed mAs chart may be most effective with:
Free
(Multiple Choice)
4.8/5
(39)
Correct Answer:
D
Newer x-ray units may keep you from making an exposure if you've selected the table Bucky on the control panel but there's no IR in the table Bucky.
(True/False)
4.7/5
(34)
With a CR system,when using AEC to image a patient who is having difficulty holding still,increasing the mA (if the unit allows)will:
(Multiple Choice)
4.8/5
(29)
The most common cause for repeating images done with film-screen and AEC is inaccurate:
(Multiple Choice)
4.9/5
(34)
What is the appropriate change in kVp when using a variable kVp-fixed mAs technique chart for a 1 cm change in tissue thickness?
(Multiple Choice)
4.8/5
(23)
When using a fixed kVp-variable mAs technique chart,if part thickness increases by 5 cm,what needs to happen to the mAs?
(Multiple Choice)
4.8/5
(24)
When using AEC with film-screen,what should the radiographer adjust to manipulate the overall density of the image?
(Multiple Choice)
4.9/5
(31)
What kind of chart uses a kVp value that is high enough to adequately penetrate the part but does not diminish radiographic contrast?
(Multiple Choice)
4.9/5
(30)
Once a predetermined amount of radiation is transmitted through a patient to the AEC detector,which of the following occurs?
(Multiple Choice)
4.8/5
(32)
Exposure time will ______ using AEC when patient thickness decreases.
(Multiple Choice)
4.8/5
(41)
Where is the sensor located in an automatic exposure device that converts light into an electrical signal?
(Multiple Choice)
4.9/5
(36)
With modern x-ray equipment,the AEC system's minimum response time is typically:
(Multiple Choice)
4.9/5
(33)
Where is the sensor located in an automatic exposure device with a gas-filled chamber?
(Multiple Choice)
4.9/5
(36)
Two identical rooms having the same generator and tube and installed at the same time do not require development of separate technique charts.The chart for one room can accurately be used in the other.
(True/False)
4.9/5
(30)