Exam 9: Image Evaluation

arrow
  • Select Tags
search iconSearch Question
flashcardsStudy Flashcards
  • Select Tags

Using a Konica digital imaging system,if an image's S number is 600 while the optimal range ends at 300,this means that the IR was ______________ and the exposure to the IR needs to be ___________________.

Free
(Multiple Choice)
4.8/5
(41)
Correct Answer:
Verified

A

In order to produce a radiographic image with structural lines as accurate as possible,you must maximize the spatial resolution and distortion.

Free
(True/False)
4.9/5
(35)
Correct Answer:
Verified

False

Assuming no other changes are made,which of the following would result in increased quantum noise in a digital image? 1)Decreasing mAs 2)Increasing kVp 3)Imaging a thicker part

Free
(Multiple Choice)
4.7/5
(30)
Correct Answer:
Verified

B

Using an Agfa digital imaging system,if an image's exposure indicator is 2.3 lgM while the optimal range begins at 2.6 lgM,this means that the IR was ______________ and the exposure to the IR needs to be ___________________ .

(Multiple Choice)
4.8/5
(26)

Which of the following changes would produce a digital image with decreased brightness?

(Multiple Choice)
4.8/5
(28)

A digital image with higher contrast may be due to: 1)Decreased kVp 2)Increased grid ratio 3)Decreased patient thickness

(Multiple Choice)
4.7/5
(36)

A film-screen image with lower contrast may be due to: 1)Increased patient thickness 2)Increased beam restriction 3)Increased kVp

(Multiple Choice)
4.7/5
(36)

When using a digital imaging system,changing from 40 in SID to 72 in SID would result in _____________ brightness and ____________ contrast.

(Multiple Choice)
4.8/5
(30)

When using a film-screen imaging system,changing from small to large focal spot size would result in _____________ density and ____________ recorded detail.

(Multiple Choice)
4.8/5
(34)

Which of the following would reduce quantum noise in a digital image? 1)Decreasing mAs 2)Increasing mAs 3)Changing to a lower ratio grid

(Multiple Choice)
4.8/5
(37)

A film-screen image with increased recorded detail may be due to: 1)Increased SID 2)Decreased focal spot size 3)Decreased film-screen speed

(Multiple Choice)
4.9/5
(46)

Artifacts are detrimental to radiographs because they can make the visibility of anatomy,pathologic conditions,or patient identification information difficult or impossible.

(True/False)
4.9/5
(38)

A digital image with decreased spatial resolution may be due to: 1)Increased central ray angulation 2)Decreased grid ratio 3)Decreased SID

(Multiple Choice)
4.8/5
(33)

The variation in brightness and density on digital or film imaging is the:

(Multiple Choice)
4.9/5
(42)

A film-screen image with decreased distortion may be due to: 1)Decreased patient thickness 2)Increased SID 3)Increased focal spot size

(Multiple Choice)
4.9/5
(37)

The amount of luminance (light emission)of a display monitor is the:

(Multiple Choice)
4.9/5
(37)

When using a digital imaging system,changing from 8 × 10 collimation to 14 × 17 collimation would result in _____________ brightness and ____________ contrast.

(Multiple Choice)
4.8/5
(38)

Using a Carestream digital imaging system,if an image's EI number is 1800 while the optimal range ends at 1200,this means that the IR was ______________ and the exposure to the IR needs to be ___________________.

(Multiple Choice)
4.8/5
(34)

A film-screen image with increased density may be due to: 1)Increased OID 2)Decreased SID 3)Increased film-screen speed

(Multiple Choice)
4.9/5
(38)

An area of decreased brightness visualized on a computer monitor has ________density on a film image.

(Multiple Choice)
4.8/5
(38)
Showing 1 - 20 of 25