Using a Konica digital imaging system,if an image's S number is 600 while the optimal range ends at 300,this means that the IR was ______________ and the exposure to the IR needs to be ___________________.
Free
(Multiple Choice)
4.8/5
(41)
Correct Answer:
A
In order to produce a radiographic image with structural lines as accurate as possible,you must maximize the spatial resolution and distortion.
Free
(True/False)
4.9/5
(35)
Correct Answer:
False
Assuming no other changes are made,which of the following would result in increased quantum noise in a digital image?
1)Decreasing mAs
2)Increasing kVp
3)Imaging a thicker part
Free
(Multiple Choice)
4.7/5
(30)
Correct Answer:
B
Using an Agfa digital imaging system,if an image's exposure indicator is 2.3 lgM while the optimal range begins at 2.6 lgM,this means that the IR was ______________ and the exposure to the IR needs to be ___________________ .
(Multiple Choice)
4.8/5
(26)
Which of the following changes would produce a digital image with decreased brightness?
(Multiple Choice)
4.8/5
(28)
A digital image with higher contrast may be due to:
1)Decreased kVp
2)Increased grid ratio
3)Decreased patient thickness
(Multiple Choice)
4.7/5
(36)
A film-screen image with lower contrast may be due to:
1)Increased patient thickness
2)Increased beam restriction
3)Increased kVp
(Multiple Choice)
4.7/5
(36)
When using a digital imaging system,changing from 40 in SID to 72 in SID would result in _____________ brightness and ____________ contrast.
(Multiple Choice)
4.8/5
(30)
When using a film-screen imaging system,changing from small to large focal spot size would result in _____________ density and ____________ recorded detail.
(Multiple Choice)
4.8/5
(34)
Which of the following would reduce quantum noise in a digital image?
1)Decreasing mAs
2)Increasing mAs
3)Changing to a lower ratio grid
(Multiple Choice)
4.8/5
(37)
A film-screen image with increased recorded detail may be due to:
1)Increased SID
2)Decreased focal spot size
3)Decreased film-screen speed
(Multiple Choice)
4.9/5
(46)
Artifacts are detrimental to radiographs because they can make the visibility of anatomy,pathologic conditions,or patient identification information difficult or impossible.
(True/False)
4.9/5
(38)
A digital image with decreased spatial resolution may be due to:
1)Increased central ray angulation
2)Decreased grid ratio
3)Decreased SID
(Multiple Choice)
4.8/5
(33)
The variation in brightness and density on digital or film imaging is the:
(Multiple Choice)
4.9/5
(42)
A film-screen image with decreased distortion may be due to:
1)Decreased patient thickness
2)Increased SID
3)Increased focal spot size
(Multiple Choice)
4.9/5
(37)
The amount of luminance (light emission)of a display monitor is the:
(Multiple Choice)
4.9/5
(37)
When using a digital imaging system,changing from 8 × 10 collimation to 14 × 17 collimation would result in _____________ brightness and ____________ contrast.
(Multiple Choice)
4.8/5
(38)
Using a Carestream digital imaging system,if an image's EI number is 1800 while the optimal range ends at 1200,this means that the IR was ______________ and the exposure to the IR needs to be ___________________.
(Multiple Choice)
4.8/5
(34)
A film-screen image with increased density may be due to:
1)Increased OID
2)Decreased SID
3)Increased film-screen speed
(Multiple Choice)
4.9/5
(38)
An area of decreased brightness visualized on a computer monitor has ________density on a film image.
(Multiple Choice)
4.8/5
(38)