Exam 5: Data Acquisition Concepts
Exam 1: Computed Tomography: An Overview40 Questions
Exam 2: Introduction to Computers60 Questions
Exam 3: Digital Image Processing48 Questions
Exam 4: Physical Principles of Computed Tomography50 Questions
Exam 5: Data Acquisition Concepts50 Questions
Exam 6: Image Reconstruction35 Questions
Exam 7: Basic Instrumentation39 Questions
Exam 8: Image Postprocessing and Visualization Tools35 Questions
Exam 9: Image Quality40 Questions
Exam 10: Radiation Dose in Computed Tomography49 Questions
Exam 11: Single-Slice Spiralhelical Computed Tomography: Physical Principles and Instrumentation30 Questions
Exam 12: Multislice Spiralhelical Computed Tomography: Physical Principles and Instrumentation40 Questions
Exam 13: Other Technical Applications of Computed Tomography Imaging: Basic Principles50 Questions
Exam 14: Three-Dimensional Computed Tomography: Basic Concepts40 Questions
Exam 15: Virtual Reality Imaging20 Questions
Exam 16: Positron Emission Tomographycomputed Tomography Scanners25 Questions
Exam 17: Computed Tomography of the Head, Cerebral Vessels, Neck, and Spine55 Questions
Exam 18: Computed Tomography of the Body40 Questions
Exam 19: Pediatric Computed Tomography30 Questions
Exam 20: Quality Control for Computed Tomography Scanners21 Questions
Select questions type
Seventh-generation scanners use flat-panel digital area detectors.
Free
(True/False)
4.9/5
(27)
Correct Answer:
True
The overall goal of the electron-beam computed tomography scanner is to produce low-resolution images of moving organs that are free of artifacts caused by motion.
Free
(True/False)
4.9/5
(35)
Correct Answer:
False
In one type of fourth-generation computed tomography scanner, the tilting action of the detector ring is referred to as:
Free
(Multiple Choice)
4.7/5
(30)
Correct Answer:
B
The change of attenuation and thickness data into transmission measurement is called efficiency conversion.
(True/False)
4.8/5
(42)
Match the following data acquisition concepts. All answer selections will be used just once.
-Ionization detector
(Multiple Choice)
4.9/5
(39)
The speed with which a computed tomography detector can detect an x-ray event and recover to detect another event is the:
(Multiple Choice)
4.9/5
(32)
Optoelectronics refers to the use of lens and light diodes to facilitate data transmission.
(True/False)
4.8/5
(38)
Gas ionization computed tomography detectors convert x ray photons into electrical signals with no light conversion process in between.
(True/False)
5.0/5
(33)
Electromechanical devices made up of rings and brushes to transmit electrical energy across a rotating interface are called:
(Multiple Choice)
4.8/5
(38)
Scintillation detectors convert x-ray photons to light and subsequently to electrical signals.
(True/False)
4.9/5
(28)
Computed tomography detectors generate a signal that represents the attenuation as the ray moves across the slice. This signal is called:
(Multiple Choice)
4.7/5
(39)
The configuration of the dual-row detector system results in faster volume coverage compared with single-row computed tomography systems.
(True/False)
4.8/5
(34)
Which generation of scanners, also called dual-source computed tomography scanners, consists of two x-ray tubes and two sets of detectors?
(Multiple Choice)
4.8/5
(37)
Which of the following refers to the ability of the computed tomography detector to capture, absorb, and convert x-ray photons into electrical energy?
(Multiple Choice)
4.9/5
(27)
In which scanner is the apex of the fan beam located outside the detector?
(Multiple Choice)
4.8/5
(39)
Compared with conventional computed tomography scanners, slip-ring scanners offer the following advantage(s): I. removal of cable wraparound
II. elimination of start-stop action
III. continuous rotation of x-ray tube and minimal interscan delays
(Multiple Choice)
4.8/5
(42)
The high-voltage generators of slip-ring scanners are located in the gantry.
(True/False)
4.9/5
(31)
Which detector characteristic refers to the steadiness of the detector response?
(Multiple Choice)
4.8/5
(34)
Which of the following refers to the size, shape, motion, and path traced by the x-ray beam as it scans the patient?
(Multiple Choice)
4.9/5
(37)
Showing 1 - 20 of 50
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)