Exam 5: Data Acquisition Concepts

arrow
  • Select Tags
search iconSearch Question
flashcardsStudy Flashcards
  • Select Tags

Seventh-generation scanners use flat-panel digital area detectors.

Free
(True/False)
4.9/5
(27)
Correct Answer:
Verified

True

The overall goal of the electron-beam computed tomography scanner is to produce low-resolution images of moving organs that are free of artifacts caused by motion.

Free
(True/False)
4.9/5
(35)
Correct Answer:
Verified

False

In one type of fourth-generation computed tomography scanner, the tilting action of the detector ring is referred to as:

Free
(Multiple Choice)
4.7/5
(30)
Correct Answer:
Verified

B

The change of attenuation and thickness data into transmission measurement is called efficiency conversion.

(True/False)
4.8/5
(42)

Match the following data acquisition concepts. All answer selections will be used just once. -Ionization detector

(Multiple Choice)
4.9/5
(39)

The speed with which a computed tomography detector can detect an x-ray event and recover to detect another event is the:

(Multiple Choice)
4.9/5
(32)

Optoelectronics refers to the use of lens and light diodes to facilitate data transmission.

(True/False)
4.8/5
(38)

Gas ionization computed tomography detectors convert x ray photons into electrical signals with no light conversion process in between.

(True/False)
5.0/5
(33)

Electromechanical devices made up of rings and brushes to transmit electrical energy across a rotating interface are called:

(Multiple Choice)
4.8/5
(38)

Which scanner is based on slip-ring technology?

(Multiple Choice)
4.8/5
(30)

Scintillation detectors convert x-ray photons to light and subsequently to electrical signals.

(True/False)
4.9/5
(28)

Computed tomography detectors generate a signal that represents the attenuation as the ray moves across the slice. This signal is called:

(Multiple Choice)
4.7/5
(39)

The configuration of the dual-row detector system results in faster volume coverage compared with single-row computed tomography systems.

(True/False)
4.8/5
(34)

Which generation of scanners, also called dual-source computed tomography scanners, consists of two x-ray tubes and two sets of detectors?

(Multiple Choice)
4.8/5
(37)

Which of the following refers to the ability of the computed tomography detector to capture, absorb, and convert x-ray photons into electrical energy?

(Multiple Choice)
4.9/5
(27)

In which scanner is the apex of the fan beam located outside the detector?

(Multiple Choice)
4.8/5
(39)

Compared with conventional computed tomography scanners, slip-ring scanners offer the following advantage(s): I. removal of cable wraparound II. elimination of start-stop action III. continuous rotation of x-ray tube and minimal interscan delays

(Multiple Choice)
4.8/5
(42)

The high-voltage generators of slip-ring scanners are located in the gantry.

(True/False)
4.9/5
(31)

Which detector characteristic refers to the steadiness of the detector response?

(Multiple Choice)
4.8/5
(34)

Which of the following refers to the size, shape, motion, and path traced by the x-ray beam as it scans the patient?

(Multiple Choice)
4.9/5
(37)
Showing 1 - 20 of 50
close modal

Filters

  • Essay(0)
  • Multiple Choice(0)
  • Short Answer(0)
  • True False(0)
  • Matching(0)