Match the following data acquisition concepts. All answer selections will be used just once. -Filtration

(Multiple Choice)
4.9/5
(31)

The scanner that uses an electron gun to "shoot" electrons toward a target ring is the:

(Multiple Choice)
4.8/5
(40)

The purpose of collimation in computed tomography is: I. to protect the patient II. to ensure a constant beam width at the detector III. to reduce scatter radiation

(Multiple Choice)
4.9/5
(39)

Streaking artifacts are the result of too many samples being measured by the detectors.

(True/False)
4.9/5
(29)

A single ray in computed tomography is:

(Multiple Choice)
4.8/5
(26)

Match the following data acquisition concepts. All answer selections will be used just once. -Detector electronics

(Multiple Choice)
4.9/5
(40)

Match the following data acquisition concepts. All answer selections will be used just once. -Slip-ring design

(Multiple Choice)
4.9/5
(43)

Multirow computed tomography detectors fall into two categories, namely, matrix array detectors and pixel array detectors.

(True/False)
4.9/5
(46)

Which of the following refers to a method by which the patient is systematically scanned by the x-ray tube and detectors to collect enough information for image reconstruction?

(Multiple Choice)
4.9/5
(38)

Which of the following is classified as a high-speed computed tomography scanner?

(Multiple Choice)
4.8/5
(38)

Which x-ray generator is used in modern computed tomography scanners?

(Multiple Choice)
4.7/5
(31)

Match the following data acquisition concepts. All answer selections will be used just once. -Scintillation

(Multiple Choice)
4.8/5
(46)

Gas ionization chambers were first introduced in second-generation scanners.

(True/False)
4.7/5
(45)

The total number of data samples per scan or per slice in computed tomography is the:

(Multiple Choice)
4.7/5
(46)

Match the following data acquisition concepts. All answer selections will be used just once. -Semiconductor

(Multiple Choice)
4.8/5
(27)

The following crystals have been used in scintillation computed tomography detectors except:

(Multiple Choice)
4.8/5
(36)

The slice thickness in computed tomography is determined by the:

(Multiple Choice)
4.8/5
(48)

Which scanner allows for continuous rotation of the x-ray tube while the patient moves simultaneously through the gantry aperture?

(Multiple Choice)
4.8/5
(35)

A view in computed tomography is:

(Multiple Choice)
4.7/5
(41)

The Stanton x-ray tube was designed by Toshiba Medical Systems.

(True/False)
4.9/5
(37)