Exam 19: Specific Equipment
Exam 1: Introduction to the National Electrical Code13 Questions
Exam 2: Definitions25 Questions
Exam 3: Boxes and Enclosures25 Questions
Exam 4: Cables17 Questions
Exam 5: Raceways and Conductors26 Questions
Exam 6: General Provisions25 Questions
Exam 7: Specific Provisions25 Questions
Exam 8: Load Calculations25 Questions
Exam 9: Services and Electrical Equipment27 Questions
Exam 10: Comprehensive Provisions25 Questions
Exam 11: Load Calculations14 Questions
Exam 12: General Provisions25 Questions
Exam 13: Nondwelling Load Calculations17 Questions
Exam 14: Services, Feeders, and Equipment25 Questions
Exam 15: Hazardous Classified Locations25 Questions
Exam 16: Health Care25 Questions
Exam 17: Industrial Locations25 Questions
Exam 18: Special Occupancies25 Questions
Exam 19: Specific Equipment25 Questions
Select questions type
Conductors in pipe organs shall have ____ insulation.
Free
(Multiple Choice)
4.7/5
(41)
Correct Answer:
B
Flexible metal conduit, ____ metal conduit, liquidtight flexible nonmetallic conduit, and flexible cords and cables are permitted wiring methods are permitted on the counterweight assembly and on the car assembly in elevators.
Free
(Multiple Choice)
5.0/5
(31)
Correct Answer:
C
Circuit voltage of heating/air-conditioning equipment branch circuits located on the elevator car shall not exceed ____ volts.
Free
(Multiple Choice)
4.7/5
(32)
Correct Answer:
D
A pipe organ should use a minimum of ____ AWG conductors for electronic signal circuits, and at least 26 AWG for electromagnetic valve supply.
(Multiple Choice)
4.7/5
(35)
All ____ receptacle outlets used in technical applications shall be GFCI protected.
(Multiple Choice)
4.9/5
(33)
Article 647 covers the installation and wiring of sensitive electronic equipment that is connected to a separately derived system operating at ____ volts line-to-line and 60 volts to ground.
(Multiple Choice)
4.8/5
(28)
Equipment used to combine and level-match a multiplicity of electronic signals, as from microphones, electronic instruments, and recorded audio is referred to as a(n) ____.
(Multiple Choice)
4.9/5
(40)
Each hoistway elevator pit shall have at least one ____-volt, single phase, 15- or 20-ampere duplex receptacle
(Multiple Choice)
4.7/5
(40)
Individual office furnishings of the freestanding type, or groups of individual office furnishings that are electrically connected, are mechanically contiguous, and do not exceed 30 ft when assembled, shall be permitted to connect to the building's electrical system by means of a ____.
(Multiple Choice)
4.8/5
(35)
A junction box for an underwater application shall be comprised of ____, brass, suitable plastic, or other approved corrosion-resistant material.
(Multiple Choice)
4.9/5
(29)
Where a permanently installed pool is installed, no fewer than one 125-volt 15- or 20-ampere receptacle on a general-purpose branch circuit shall be located a minimum of ____ ft, but no more than 20 ft, from the pool's inside wall.
(Multiple Choice)
4.9/5
(29)
Neon tubing secondary conductor(s) shall be supported within ____ in.of the electrode connection.
(Multiple Choice)
4.7/5
(34)
Unencapsulated structural reinforcing steel in pools shall be ____.
(Multiple Choice)
4.9/5
(37)
Electric signs and outline lighting system equipment in wet locations, unless of the listed watertight type, shall be weatherproof and, if necessary, have ____ in accordance with 600.9(D)(1) through (3).
(Multiple Choice)
5.0/5
(30)
Neon tubing's length and design shall not cause a continuous overcurrent beyond the capacity of the transformer or ____.
(Multiple Choice)
4.8/5
(24)
DC power shall be supplied by a listed dc power supply with a maximum output of ____ volts.
(Multiple Choice)
4.7/5
(36)
Unit heaters shall not be mounted over the pool or`within the area extending ____ ft horizontally from the inside walls of a pool.
(Multiple Choice)
4.8/5
(43)
An electric vehicle supply equipment's coupling means shall be stored or located at a height of not less than ____ in. above the floor level for indoor locations and 24 in. above the grade level for outdoor locations.
(Multiple Choice)
4.7/5
(33)
Branch circuits and feeders in a separately derived 60-volts to ground system shall be provided with a means to ____.
(Multiple Choice)
4.7/5
(39)
Electric signs and outline lighting systems shall be marked with the manufacturer's name, trademark or other identification, ____, and current rating.
(Multiple Choice)
4.7/5
(31)
Showing 1 - 20 of 25
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)