Skin effect and induction change the resistance in alternating-current (ac) circuits, therefore resistance of a conductor is ____.

Free
(Multiple Choice)
4.9/5
(31)
Correct Answer:
Verified

C

Service conductors supplying a building (or other structure) shall not ____.

Free
(Multiple Choice)
4.8/5
(34)
Correct Answer:
Verified

C

Kitchen receptacles not serving countertops (such as receptacles behind refrigerators) ____ unless they are installed within 6 ft of the outside edge of the sink.

Free
(Multiple Choice)
4.9/5
(39)
Correct Answer:
Verified

C

The maximum distance to any receptacle, measured horizontally along the wall line, is ____ in.

(Multiple Choice)
4.9/5
(38)

Each occupant must have ready access to ____ protecting the conductors supplying that occupancy.

(Multiple Choice)
4.9/5
(39)

The vertical clearance above roof level must be maintained for a distance of at least ____ ft from all edges of the roof.

(Multiple Choice)
4.9/5
(31)

All electric equipment must be ____ to allow ready and safe equipment operation and maintenance.

(Multiple Choice)
4.8/5
(40)

If the load requirements of a single-phase installation are greater than the serving agency normally supplies through one service, ____ are permitted.

(Multiple Choice)
4.9/5
(39)

A single-phase feeder (or branch circuit) conductor will have a total resistance ____ that of one conductor.

(Multiple Choice)
5.0/5
(40)

A drip loop's lowest point has a minimum vertical clearance of ____ ft.

(Multiple Choice)
5.0/5
(29)

The conductors and equipment that deliver energy from the electricity supply system to the wiring system of the premises are called the ____.

(Multiple Choice)
4.9/5
(36)

All 125-volt, single-phase, 15- and 20-ampere dwelling unit outdoor receptacles must have ____.

(Multiple Choice)
4.7/5
(33)

Dwelling-unit branch circuits shall supply only loads within, or associated only with, ____.

(Multiple Choice)
4.9/5
(33)

____ is the maximum number of disconnects per service grouped in any one location.

(Multiple Choice)
4.8/5
(39)

____ is defined as the underground conductors between the utility electric supply system and the service point.

(Multiple Choice)
4.9/5
(42)

The recommended voltage drop for a branch circuit is ____ % or less.

(Multiple Choice)
4.9/5
(36)

A minimum of ____ wall switch-controlled lighting outlet(s) is (are) required for dwelling hallways.

(Multiple Choice)
4.9/5
(26)

General receptacle installation provisions for multifamily dwellings are almost identical to those for ____.

(Multiple Choice)
4.9/5
(32)

Conductors must have ____ and sufficient ampacity to carry the current for the load as calculated.

(Multiple Choice)
4.8/5
(40)

The larger the circular mil area of a conductor, the ____.

(Multiple Choice)
4.7/5
(35)