Exam 10: Comprehensive Provisions
Exam 1: Introduction to the National Electrical Code13 Questions
Exam 2: Definitions25 Questions
Exam 3: Boxes and Enclosures25 Questions
Exam 4: Cables17 Questions
Exam 5: Raceways and Conductors26 Questions
Exam 6: General Provisions25 Questions
Exam 7: Specific Provisions25 Questions
Exam 8: Load Calculations25 Questions
Exam 9: Services and Electrical Equipment27 Questions
Exam 10: Comprehensive Provisions25 Questions
Exam 11: Load Calculations14 Questions
Exam 12: General Provisions25 Questions
Exam 13: Nondwelling Load Calculations17 Questions
Exam 14: Services, Feeders, and Equipment25 Questions
Exam 15: Hazardous Classified Locations25 Questions
Exam 16: Health Care25 Questions
Exam 17: Industrial Locations25 Questions
Exam 18: Special Occupancies25 Questions
Exam 19: Specific Equipment25 Questions
Select questions type
Skin effect and induction change the resistance in alternating-current (ac) circuits, therefore resistance of a conductor is ____.
Free
(Multiple Choice)
4.9/5
(31)
Correct Answer:
C
Service conductors supplying a building (or other structure) shall not ____.
Free
(Multiple Choice)
4.8/5
(34)
Correct Answer:
C
Kitchen receptacles not serving countertops (such as receptacles behind refrigerators) ____ unless they are installed within 6 ft of the outside edge of the sink.
Free
(Multiple Choice)
4.9/5
(39)
Correct Answer:
C
The maximum distance to any receptacle, measured horizontally along the wall line, is ____ in.
(Multiple Choice)
4.9/5
(38)
Each occupant must have ready access to ____ protecting the conductors supplying that occupancy.
(Multiple Choice)
4.9/5
(39)
The vertical clearance above roof level must be maintained for a distance of at least ____ ft from all edges of the roof.
(Multiple Choice)
4.9/5
(31)
All electric equipment must be ____ to allow ready and safe equipment operation and maintenance.
(Multiple Choice)
4.8/5
(40)
If the load requirements of a single-phase installation are greater than the serving agency normally supplies through one service, ____ are permitted.
(Multiple Choice)
4.9/5
(39)
A single-phase feeder (or branch circuit) conductor will have a total resistance ____ that of one conductor.
(Multiple Choice)
5.0/5
(40)
A drip loop's lowest point has a minimum vertical clearance of ____ ft.
(Multiple Choice)
5.0/5
(29)
The conductors and equipment that deliver energy from the electricity supply system to the wiring system of the premises are called the ____.
(Multiple Choice)
4.9/5
(36)
All 125-volt, single-phase, 15- and 20-ampere dwelling unit outdoor receptacles must have ____.
(Multiple Choice)
4.7/5
(33)
Dwelling-unit branch circuits shall supply only loads within, or associated only with, ____.
(Multiple Choice)
4.9/5
(33)
____ is the maximum number of disconnects per service grouped in any one location.
(Multiple Choice)
4.8/5
(39)
____ is defined as the underground conductors between the utility electric supply system and the service point.
(Multiple Choice)
4.9/5
(42)
The recommended voltage drop for a branch circuit is ____ % or less.
(Multiple Choice)
4.9/5
(36)
A minimum of ____ wall switch-controlled lighting outlet(s) is (are) required for dwelling hallways.
(Multiple Choice)
4.9/5
(26)
General receptacle installation provisions for multifamily dwellings are almost identical to those for ____.
(Multiple Choice)
4.9/5
(32)
Conductors must have ____ and sufficient ampacity to carry the current for the load as calculated.
(Multiple Choice)
4.8/5
(40)