Exam 4: Cables
Exam 1: Introduction to the National Electrical Code13 Questions
Exam 2: Definitions25 Questions
Exam 3: Boxes and Enclosures25 Questions
Exam 4: Cables17 Questions
Exam 5: Raceways and Conductors26 Questions
Exam 6: General Provisions25 Questions
Exam 7: Specific Provisions25 Questions
Exam 8: Load Calculations25 Questions
Exam 9: Services and Electrical Equipment27 Questions
Exam 10: Comprehensive Provisions25 Questions
Exam 11: Load Calculations14 Questions
Exam 12: General Provisions25 Questions
Exam 13: Nondwelling Load Calculations17 Questions
Exam 14: Services, Feeders, and Equipment25 Questions
Exam 15: Hazardous Classified Locations25 Questions
Exam 16: Health Care25 Questions
Exam 17: Industrial Locations25 Questions
Exam 18: Special Occupancies25 Questions
Exam 19: Specific Equipment25 Questions
Select questions type
Electrical installation openings that penetrate into or through fire-resistant-rated structures must be ____.
Free
(Multiple Choice)
4.8/5
(28)
Correct Answer:
A
Protection is required for cables located within 6 ft (measured both vertically and horizontally) of the ____.
Free
(Multiple Choice)
4.8/5
(34)
Correct Answer:
C
Type AC cable must have a bending radius at least ____ times the diameter of the cable.
Free
(Multiple Choice)
4.9/5
(30)
Correct Answer:
C
Cables entering or exiting conduit used for support or protection against physical damage require fittings on the conduit ends to prevent ____.
(Multiple Choice)
4.8/5
(37)
Cable installed under a building must be ____ unless the wiring method is Type MC or Type MI cable that is identified for direct burial.
(Multiple Choice)
4.9/5
(42)
.Nonmetallic-sheathed cable passing through holes (or slots) in metal framing must be protected by ____ covering all metal edges.
(Multiple Choice)
4.9/5
(25)
Cover measurement commences at the top surface of any direct burial wiring method and ends at the ____ of the finished grade's top surface.
(Multiple Choice)
4.7/5
(27)
A widely accepted practice is to identify 3-phase ungrounded (hot) conductors as ____ in 208/120 volt, 4-wire, wye-connected systems.
(Multiple Choice)
4.8/5
(31)
A cable assembly's ____ conductor can be used as a switch loop (leg) in single-pole, three-way, and four-way switch installations, even though it is an ungrounded (hot) conductor.
(Multiple Choice)
4.7/5
(39)
A key provision found in most of the cable articles states that the cable must not be installed where subject to ____.
(Multiple Choice)
4.9/5
(23)
Cables running horizontally (or diagonally) are considered supported and secured when passing through a(n) ____.
(Multiple Choice)
4.7/5
(41)
Exposed runs of Type AC cable installed on the underside of joists must be supported at ____.
(Multiple Choice)
4.8/5
(29)
Ducts used to transport dust, loose stock, or flammable vapors shall not contain ____ of any type.
(Multiple Choice)
4.8/5
(31)
Generally, ungrounded (hot) conductors can be any color except ____.
(Multiple Choice)
4.9/5
(32)
Holes must be bored so that the edge of the hole is at least ____ from the nearest edge of the wood member.
(Multiple Choice)
4.7/5
(29)
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)