What is the most common and least hazardous method used to disable an array or parts of an array?

Free
(Essay)
4.7/5
(36)
Correct Answer:
Verified

Open circuiting is the most common method of disabling an array and presents the least amount of hazard.

Direct mount is a module mounting method where the modules are secured directly to the roof surface.

Free
(True/False)
4.9/5
(31)
Correct Answer:
Verified

True

What are the six considerations for choosing a PV mounting system?

Free
(Essay)
4.8/5
(37)
Correct Answer:
Verified

Installers of a PV mounting system need to consider the orientation of the building, shading at the site, weather considerations, roof material, ground or roof bearing capacity, and the system application.

A rack type that uses masonry blocks or some other type of ballast to hold it in place is called a(n) ____________________.

(Short Answer)
4.9/5
(34)

____________________ mount systems have the modules mounted in a metal framework set at a tilt angle that can be adjusted.

(Short Answer)
4.7/5
(37)

A metal tool or other object being dropped onto the battery terminals can cause a fire or ____________________.

(Short Answer)
4.8/5
(38)

An opaque object allows light to pass through it.

(True/False)
4.9/5
(32)

With a(n) ____________________ mount system the PV modules are mounted directly to a roof and have the same tilt angle as the roof.

(Short Answer)
4.9/5
(36)

A PV system should only be considered "live" when it is in operation.

(True/False)
4.7/5
(30)

Which is usually the largest of the structural loads and what is its typical range?

(Essay)
4.8/5
(37)

Module mounting systems can be fixed tilt or ____________________ tilt.

(Short Answer)
4.8/5
(35)

The ____________________ box is usually insulated and built from materials like wood, plastic, or some other corrosion resistant painted material.

(Short Answer)
4.8/5
(30)

What are the five structural loads an installer should be aware of when determining whether a structure can be used to support a PV array and associated equipment?

(Essay)
4.9/5
(41)

A live load is a structural load that is a result of the weight of temporary items, including people, on the structure while the array is being installed.

(True/False)
4.8/5
(31)

____________________ corrosion is an electrochemical process that causes corrosion where two dissimilar metals touch.

(Short Answer)
4.8/5
(28)

What are some appropriate materials for coating battery terminals to prevent corrosion?

(Essay)
4.8/5
(37)

When does galvanic corrosion occur and how can it be prevented?

(Essay)
4.8/5
(26)

The ____________________ load is the actual weight of the PV modules, the mounting structure used, and the other balance of system (BOS) components divided by the area of the array.

(Short Answer)
4.8/5
(41)

The intentional connecting together of the PV output circuit conductors is called ____________________ circuiting.

(Short Answer)
4.7/5
(38)

The wind load is the structural load caused by the wind and resulting in downward, lateral, or lifting forces on PV modules and mounting systems.

(True/False)
4.8/5
(36)