____________________ is the current, in amperes, that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
Free
(Short Answer)
4.8/5
(43)
Correct Answer:
Ampacity
Write the common formula used to calculate voltage drop.
Free
(Essay)
4.9/5
(43)
Correct Answer:
The common formula used to calculate voltage drop is:
If conductors are installed in conduit located outside of a building or underground in a trench, you need to use 90° C, wet rated conductors.
Free
(True/False)
4.9/5
(28)
Correct Answer:
True
Why is there a need to consider voltage drop when installing long runs of wiring as part of a PV system?
(Essay)
4.8/5
(36)
Every circuit must be protected from an electrical current that exceeds the conductor's voltage.
(True/False)
4.8/5
(37)
Conductor ampacity must be derated for high ambient temperatures when the ambient temperature around the conductor is higher than the base temperature rating of 30° C (86° F).
(True/False)
5.0/5
(34)
There are two types of overcurrent devices used in PV systems: ____________________ and circuit breakers
(Short Answer)
4.8/5
(35)
The conductors between the inverter and the batteries in a stand-alone system, or the conductors between the inverter and the photovoltaic output circuit in a grid-tie system, are referred to as the inverter output circuit.
(True/False)
4.8/5
(29)
A junction box typically located at the PV array location where two or more PV source circuits are connected together is called a(n) ____________________ box.
(Short Answer)
4.8/5
(33)
Describe the two exceptions in NEC Section 690.13 that deal with disconnecting grounded connectors.
(Essay)
4.8/5
(39)
What is typically used to house source circuit OCPDs in a roof-mount PV array and where is it located?
(Essay)
4.9/5
(40)
What two criteria must an installer consider with conductor sizing for a PV system?
(Essay)
4.7/5
(39)
A grounded conductor is a system or circuit conductor that is intentionally grounded.
(True/False)
4.9/5
(36)
PV system installers must install the correct type of ____________________ for a PV system to be National Electrical Code compliant.
(Short Answer)
4.8/5
(36)
Type NM, Type UF, Type AC, Type MC, and Type USE are all ____________________ types.
(Short Answer)
4.8/5
(35)
There are two types of grounding in a PV system: ____________________ grounding and equipment grounding.
(Short Answer)
4.9/5
(36)