Exam 15: Direct Current Generators and Parallel Operation
Exam 1: Transformer Fundamentals and Operation25 Questions
Exam 2: Transformer Technology and Design25 Questions
Exam 3: Transformer: Resistance, Oil, Relays, Harmonics, and Core Properties25 Questions
Exam 4: Transformers: Efficiency, Design, and Testing25 Questions
Exam 5: Transformers: Voltage Regulation, Efficiency, and Protection25 Questions
Exam 6: Transformer and D.C Motor25 Questions
Exam 7: D.C Motors and Starters25 Questions
Exam 8: D.C Motors and Speed Control25 Questions
Exam 9: D.C Motors and Controls25 Questions
Exam 10: D.C Motors and Generators25 Questions
Exam 11: D.C Machine and Generator Laminations, Commutation, and Components25 Questions
Exam 12: D.C Generators and Commutators25 Questions
Exam 13: D.C Generator Operation and Construction25 Questions
Exam 14: D.C Generators25 Questions
Exam 15: Direct Current Generators and Parallel Operation18 Questions
Select questions type
Which generator would you prefer for feeding long D.C. transmission lines ?
Free
(Multiple Choice)
4.9/5
(35)
Correct Answer:
C
Shunt generators are most suited for stable parallel operation because of their
Free
(Multiple Choice)
4.9/5
(35)
Correct Answer:
C
The essential condition for parallel operation of two D.C. generators is that they have '
Free
(Multiple Choice)
4.8/5
(38)
Correct Answer:
C
The open circuit voltage of a compound generator is 250 V. At full load the terminal voltage
(Multiple Choice)
4.7/5
(28)
Two D.C. shunt generators, each with armature resistance of 0.02 ohm and field resistance of 50 ohm run in parallel and supply a total current of 1000 amperes to the load circuit. If their e.m.fs. are 270 V and 265 V, their bus bar voltage will be
(Multiple Choice)
4.9/5
(35)
The number of armature parallel paths in a two-pole D.C. generator having duplexlap winding is
(Multiple Choice)
4.8/5
(43)
In a D.C. generator the critical resistance can be increased by
(Multiple Choice)
4.8/5
(45)
The series field of a short-shunt D.C. generator is excited by
(Multiple Choice)
5.0/5
(37)
The terminal voltage of a series generator is 150 V when the load current is 5 A. If the load current is increased to 10 A, the terminal voltage will be
(Multiple Choice)
4.9/5
(45)
As a result of armature reaction, the reduction in the total mutual air gap flux in aD.C. generator is approximately
(Multiple Choice)
4.9/5
(37)
Two generators are running in parallel. One of the generators may run as motor for which of the following reasons ?
(Multiple Choice)
4.9/5
(42)
The main factor which leads to unstable parallel operation of flat and over compounded generators is
(Multiple Choice)
4.9/5
(33)
For both lap and wave windings, there are as many commutator bars as the numberof
(Multiple Choice)
4.8/5
(28)
When two D.C. generators are running in parallel an equilizer bar is used
(Multiple Choice)
4.8/5
(31)
With a D.C. generator which of the following regulation is preferred ?
(Multiple Choice)
4.8/5
(41)
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)