Exam 15: Direct Current Generators and Parallel Operation

arrow
  • Select Tags
search iconSearch Question
flashcardsStudy Flashcards
  • Select Tags

Which generator would you prefer for feeding long D.C. transmission lines ?

Free
(Multiple Choice)
4.9/5
(35)
Correct Answer:
Verified

C

Shunt generators are most suited for stable parallel operation because of their

Free
(Multiple Choice)
4.9/5
(35)
Correct Answer:
Verified

C

The essential condition for parallel operation of two D.C. generators is that they have '

Free
(Multiple Choice)
4.8/5
(38)
Correct Answer:
Verified

C

The open circuit voltage of a compound generator is 250 V. At full load the terminal voltage

(Multiple Choice)
4.7/5
(28)

Two D.C. shunt generators, each with armature resistance of 0.02 ohm and field resistance of 50 ohm run in parallel and supply a total current of 1000 amperes to the load circuit. If their e.m.fs. are 270 V and 265 V, their bus bar voltage will be

(Multiple Choice)
4.9/5
(35)

The number of armature parallel paths in a two-pole D.C. generator having duplexlap winding is

(Multiple Choice)
4.8/5
(43)

In a D.C. generator the critical resistance can be increased by

(Multiple Choice)
4.8/5
(45)

The series field of a short-shunt D.C. generator is excited by

(Multiple Choice)
5.0/5
(37)

The terminal voltage of a series generator is 150 V when the load current is 5 A. If the load current is increased to 10 A, the terminal voltage will be

(Multiple Choice)
4.9/5
(45)

A D.C. generator works on the principle of

(Multiple Choice)
5.0/5
(35)

A shunt generator can self-excite

(Multiple Choice)
4.7/5
(38)

As a result of armature reaction, the reduction in the total mutual air gap flux in aD.C. generator is approximately

(Multiple Choice)
4.9/5
(37)

A series generator can self-excite

(Multiple Choice)
4.8/5
(41)

Two generators are running in parallel. One of the generators may run as motor for which of the following reasons ?

(Multiple Choice)
4.9/5
(42)

The main factor which leads to unstable parallel operation of flat and over compounded generators is

(Multiple Choice)
4.9/5
(33)

For both lap and wave windings, there are as many commutator bars as the numberof

(Multiple Choice)
4.8/5
(28)

When two D.C. generators are running in parallel an equilizer bar is used

(Multiple Choice)
4.8/5
(31)

With a D.C. generator which of the following regulation is preferred ?

(Multiple Choice)
4.8/5
(41)
close modal

Filters

  • Essay(0)
  • Multiple Choice(0)
  • Short Answer(0)
  • True False(0)
  • Matching(0)