Anatomically programmed radiography (APR)is a system in which the radiographer selects

(Multiple Choice)
4.8/5
(42)

When using AEC,destructive pathologic conditions can cause

(Multiple Choice)
4.9/5
(34)

Using a higher kVp during an AEC examination results in

(Multiple Choice)
5.0/5
(42)

The AEC minimum response time may pose a problem when

(Multiple Choice)
4.9/5
(34)

It is safe to assume that APR settings have been developed to produce the best quality images with the least amount of exposure.

(True/False)
4.9/5
(33)

With film-screen imaging using AEC,if an AP thoracic spine is imaged with the central ray passing 3 inches to the right of the spine,the density in the area of interest will be __________________ and the exposure time will be ________________________.(Assume all other factors are appropriate. )

(Multiple Choice)
4.8/5
(33)

When there is a significant amount of scatter radiation reaching the detector,the exposure time will

(Multiple Choice)
5.0/5
(36)

Using the plus or minus density controls should be done frequently to produce optimal images with AEC.

(True/False)
4.8/5
(46)

The shortest exposure time that a radiographic tube with AEC can have is the

(Multiple Choice)
4.9/5
(39)

The detector(s)selected for an image should be

(Multiple Choice)
4.9/5
(41)

When using AEC,the exit radiation is converted into an electrical signal.

(True/False)
4.7/5
(38)

Phototimer AEC detectors are usually exit-type devices because

(Multiple Choice)
4.7/5
(38)

With film-screen imaging using AEC,if an AP thoracic spine is imaged using 110 kVp instead of 80 kVp,the density in the area of interest will be __________________ and the image contrast will be ________________________.(Assume all other factors are appropriate. )

(Multiple Choice)
4.9/5
(34)

___________________ identify optimal kVp values and alter the mAs for variations in part thickness

(Multiple Choice)
4.7/5
(40)

Collimation is not required when AEC is used.

(True/False)
4.8/5
(31)

The predetermined level of radiation exposure needed to terminate the exposure when using AEC is set by

(Multiple Choice)
4.8/5
(25)

If the AEC detectors are not completely covered by the part being imaged and are exposed to primary radiation

(Multiple Choice)
5.0/5
(40)

If the radiographer is doing an upright chest using AEC but the table bucky is selected

(Multiple Choice)
4.9/5
(42)

These can be adjusted to increase or decrease the amount of radiation needed to terminate the exposure using AEC

(Multiple Choice)
4.8/5
(43)

The reason to have a back-up time is to

(Multiple Choice)
4.9/5
(38)