Exam 17: Hydronic Heat

arrow
  • Select Tags
search iconSearch Question
flashcardsStudy Flashcards
  • Select Tags

The desired floor temperature for a radiant floor heating system is ____ degrees.

Free
(Multiple Choice)
4.9/5
(30)
Correct Answer:
Verified

B

What is another name for a flow control valve?

Free
(Short Answer)
4.9/5
(29)
Correct Answer:
Verified

check valve

Which type of expansion tank can become water-logged?

Free
(Multiple Choice)
4.9/5
(36)
Correct Answer:
Verified

A

In a series loop system,the last heater in the circuit will be the warmest.

(True/False)
4.7/5
(33)

If an expansion tank were pressurized to 15 psig when installed,and the pump generates a pressure difference of 20 psig,the point of no pressure change for the system would be ____.

(Multiple Choice)
4.8/5
(38)

Radiant heating systems typically heat the water in the ____ degree range.

(Multiple Choice)
4.7/5
(34)

The majority of radiant heating piping systems are located in the ____.

(Multiple Choice)
4.7/5
(33)

Which pipe is most commonly used in radiant heating systems?

(Multiple Choice)
4.9/5
(35)

Under normal conditions,the human body produces approximately ____ btus.

(Multiple Choice)
4.9/5
(35)

Which control will prevent the "dry firing " of the boiler?

(Multiple Choice)
4.9/5
(38)

What does the acronym ASME stand for when referring to hydronic heating systems?

(Short Answer)
4.7/5
(29)

At what pressure do most residential relief valves open?

(Multiple Choice)
4.7/5
(31)

A circulator pump should always be installed so that the water is pumped away from the expansion tank.

(True/False)
4.7/5
(29)

When troubleshooting a three zone hydronic heating system,the technician observes that two zones are operating correctly while the third zone is not getting warm during a call for heat,what is the most likely problem?

(Multiple Choice)
4.8/5
(38)

When troubleshooting a residential hydronic heating system,the technician notices that the burner keeps going out on high limit,what is the most likely cause?

(Multiple Choice)
4.8/5
(30)

In a one-pipe system,the same pipe that carries the supply water from the boiler also carries the return water back to the boiler.

(True/False)
4.7/5
(38)

A reset control will adjust the water temperature of the boiler according to the _______________ temperature.

(Short Answer)
4.8/5
(36)

In which type of piping system is the first heating unit supplied with hot water also the last heater to return its water to the boiler?

(Multiple Choice)
4.7/5
(28)

As water is heated,the volume of the water is decreased.

(True/False)
4.7/5
(36)

Which is the best method for checking the pressure in an expansion tank?

(Multiple Choice)
4.8/5
(33)
Showing 1 - 20 of 25