Exam 14: Multiple Push Button Stations and Hand-Off-Automatic Controls
Exam 1: General Principles of Motor Control, Symbols and Schematic Diagrams11 Questions
Exam 2: Manual Starters and Overload Relays13 Questions
Exam 3: The Control Transformer, Relays, Contactors, and Motor Starters13 Questions
Exam 4: Timing Relays, Pressure Switches and Sensors15 Questions
Exam 5: Float Switches, Flow Switches and Sensors11 Questions
Exam 6: Limit Switches and Phase Failure Relays13 Questions
Exam 7: Temperature Sensing, Devices M Solenoid and Motor Operated Valves12 Questions
Exam 8: Hall Effect Sensors and Proximity Detectors12 Questions
Exam 9: Basic Control Circuits and Photodetectors14 Questions
Exam 10: Schematics, Wiring Diagrams Circuit (1), Timed Starting for Three Motors Circuit (2)10 Questions
Exam 11: Float Switch Control of a Pump and Pilot Lights Circuit (3), Developing a Wiring Diagram Circuit (1)8 Questions
Exam 12: Developing a Wiring Diagram Circuit (2) and Developing a Wiring Diagram Circuit (3)6 Questions
Exam 13: Installing Control Systems and Reading Large Schematic Diagrams13 Questions
Exam 14: Multiple Push Button Stations and Hand-Off-Automatic Controls13 Questions
Exam 15: Forward-Reverse Control, Jogging and Inching14 Questions
Exam 16: Dc Motors and Sequence Control14 Questions
Exam 17: Solid-State Dc Drives and Starting Methods for DC Motors13 Questions
Exam 18: Stepping Motors, the Motor and Starting Methods14 Questions
Exam 19: Autotransformer Starting , Resistor and Reactor Starting for Ac Motors14 Questions
Exam 20: Wye-Delta Starting, Part Winding Starters9 Questions
Exam 21: Braking , Consequent Pole Motors, Variable Voltage and Magnetic Clutches14 Questions
Exam 22: Variable Frequency Control14 Questions
Exam 23: Troubleshooting, Motor Installation and Developing Control Circuits19 Questions
Exam 51: Digital Logic and the Bounceless Switch14 Questions
Exam 25: Programmable Logic Controllers and Start-Stop Push Button Control14 Questions
Exam 26: Programming a PLC and Analog Sensing for Programmable Controllers10 Questions
Select questions type
What happens when the hand-off-automatic switch is set in the Hand position?
Free
(Essay)
4.7/5
(33)
Correct Answer:
When the hand-off-automatic switch is set in the Hand position, connection is made between terminals 1 and 2. This permits the motor to be controlled by a start-stop push-button station. In this mode, the fan will run continuously until the Stop button is pressed.
When the M coil energizes, what happens to the normally open auxiliary contact?
Free
(Essay)
4.7/5
(42)
Correct Answer:
When the M coil energizes, the normally open auxiliary contact connected in parallel with the two Start buttons closes to maintain the circuit to M coil when the Start button is released.
A(n) ____________________ lamp indicates that there is no flow of water when the circuit is energized.
Free
(Short Answer)
4.7/5
(41)
Correct Answer:
warning
After wire numbers are placed on the schematic, corresponding numbers are placed on the control components.
(True/False)
4.8/5
(32)
A flow switch can be used to detect the flow of water to ensure that a fan motor cannot run if there is no flow of cooling water.
(True/False)
4.8/5
(29)
A(n) ____________________ line indicates that two switches are mechanically connected.
(Short Answer)
4.8/5
(35)
One terminal of both a normally open switch and normally closed switch are connected together. This forms a common point for both switches and could be used as the common terminal for a flow switch that contains a ____ switch.
(Multiple Choice)
4.7/5
(42)
When a component is used to perform the function of stop in a control circuit, it will generally be a normally ____ component and be connected in ____ with the motor starter coil.
(Multiple Choice)
5.0/5
(29)
Hand-off-automatic controls are used to prevent an operator from selecting between automatic or manual operation of a motor.
(True/False)
4.9/5
(24)
When the HOA switch is placed in the Auto position, a(n) ____ controls the action of the fan.
(Multiple Choice)
4.8/5
(41)
Consider a circuit needing a flow switch with two separate contacts, one normally open and the other normally closed. When one switch changes position, the other switch changes position. What happens if a flow switch with two separate switches cannot be obtained?
(Essay)
4.8/5
(51)
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)