Exam 35: Fire Rated and Acoustical Considerations

arrow
  • Select Tags
search iconSearch Question
flashcardsStudy Flashcards
  • Select Tags

The principles that are used to stop the flow of sound through walls also apply to the floor/ceiling assembly, and wall construction is same for floor/ceiling construction.

Free
(True/False)
4.8/5
(37)
Correct Answer:
Verified

False

Sound is transmitted by __________ in any material: solid, liquid, or gas.

Free
(Multiple Choice)
4.9/5
(29)
Correct Answer:
Verified

B

Varying degrees of fire resistance can be achieved by using a second layer of fire-rated ______ on one or both sides of the wall.

Free
(Multiple Choice)
4.7/5
(40)
Correct Answer:
Verified

A

A rating of _________ IIC for the floor would be the most satisfying for individuals.

(Multiple Choice)
4.9/5
(38)

Openings are rarely avoided in fire-rated walls.

(True/False)
4.8/5
(34)

To prevent vertical flame spread, stud spaces are not permitted to be more than ____ high.

(Multiple Choice)
4.8/5
(28)

An STC of 45 is achieved without clips by using 2 x 4 studs and 2 x 6 plates.

(True/False)
4.8/5
(39)

The spaces between the studs are closed off with ____ at each level.

(Multiple Choice)
4.9/5
(33)

The sound transmission classification of a wall can be improved greatly by allowing the studs to contact both surfaces.

(True/False)
4.9/5
(30)

The Town House party walls have stricter fire-resisting requirements in some places than in others.

(True/False)
4.9/5
(31)

A wall that is shared by two living units in a multifamily structure is called a ____ wall.

(Multiple Choice)
4.8/5
(38)

The measurement of the capability of a building element to reduce the passage of sound is its ____ (STC).

(Multiple Choice)
4.9/5
(31)

The most obvious way in which a wall, floor, ceiling, or roof can slow the spread of fire is by having a fire-resistant ____.

(Multiple Choice)
4.8/5
(39)

Fire-rated doors are ____ allowed to have a slightly lower rating than the walls in which they are installed.

(Multiple Choice)
4.9/5
(41)

Type ____ wallboard is a special fire-rated wallboard.

(Multiple Choice)
4.8/5
(30)

Party walls are often required to have double thicknesses of ____ on each side.

(Multiple Choice)
4.9/5
(32)

Using clips and sound-deadening fiberboard results in an STC rating of ____.

(Multiple Choice)
4.8/5
(35)

Approved fire ____ or fill must be used at all utility-line fire-rated wall penetrations.

(Multiple Choice)
4.8/5
(34)

Instead of wood firestops, the wall cavity can be blocked off with fire-resistant ____ insulation.

(Multiple Choice)
4.8/5
(35)

An STC of 45 can be increased to 49 by including ____ insulation.

(Multiple Choice)
4.8/5
(31)
Showing 1 - 20 of 24
close modal

Filters

  • Essay(0)
  • Multiple Choice(0)
  • Short Answer(0)
  • True False(0)
  • Matching(0)