Exam 39: Automation in Hematology
Exam 1: Introduction30 Questions
Exam 2: Cellular Homeostasis40 Questions
Exam 3: Structure and Function of Hematopoietic Organs35 Questions
Exam 4: Hematopoiesis35 Questions
Exam 5: The Erythrocyte37 Questions
Exam 6: Hemoglobin40 Questions
Exam 7: Granulocytes and Monocytes30 Questions
Exam 8: Lymphocytes25 Questions
Exam 9: The Platelet16 Questions
Exam 10: The Complete Blood Count and Peripheral Blood Smear Evaluation35 Questions
Exam 11: Introduction to Anemia35 Questions
Exam 12: Anemias of Disordered Iron Metabolism and Heme Synthesis36 Questions
Exam 13: Hemoglobinopathies: Qualitative Defects33 Questions
Exam 14: Thalassemia32 Questions
Exam 15: Megaloblastic and Nonmegaloblastic Macrocytic Anemias34 Questions
Exam 16: Hypoproliferative Anemias32 Questions
Exam 17: Hemolytic Anemia: Membrane Defects36 Questions
Exam 18: Hemolytic Anemia: Enzyme Deficiencies36 Questions
Exam 19: Hemolytic Anemia: Immune Anemias30 Questions
Exam 20: Hemolytic Anemia: Nonimmune Defects30 Questions
Exam 21: Nonmalignant Disorders of Leukocytes: Granulocytes and Monocytes35 Questions
Exam 22: Nonmalignant Lymphocyte Disorders32 Questions
Exam 23: Introduction to Hematopoietic Neoplasms34 Questions
Exam 24: Myeloproliferative Neoplasms44 Questions
Exam 25: Myelodysplastic Syndromes34 Questions
Exam 26: Acute Myeloid Leukemias35 Questions
Exam 27: Precursor Lymphoid Neoplasms34 Questions
Exam 28: Mature Lymphoid Neoplasms39 Questions
Exam 29: Hematopoietic Stem Cell Transplantation41 Questions
Exam 30: Morphologic Analysis of Body Fluids in the Hematology Laboratory39 Questions
Exam 31: Primary Hemostasis35 Questions
Exam 32: Secondary Hemostasis and Fibrinolysis33 Questions
Exam 33: Disorders of Primary Hemostasis35 Questions
Exam 34: Disorders of Secondary Hemostasis34 Questions
Exam 35: Thrombophilia34 Questions
Exam 36: Hemostasis: Laboratory Testing and Instrumentation41 Questions
Exam 37: Hematology Procedures46 Questions
Exam 38: Bone Marrow Examination34 Questions
Exam 39: Automation in Hematology38 Questions
Exam 40: Flow Cytometry34 Questions
Exam 41: Chromosome Analysis of Hematopoietic and Lymphoid Disorders35 Questions
Exam 42: Molecular Analysis of Hematologic Diseases18 Questions
Select questions type
Regarding the CELL-DYN Sapphire,which parameter is determined by the impedance principle?
(Multiple Choice)
4.9/5
(47)
The Sysmex XE-2100 instrument printout reports a middle fluorescent ratio of 7.0 and a high fluorescent ratio of 1.3.What is the immature reticulocyte fraction?
(Multiple Choice)
4.9/5
(34)
Which of the following is a reported parameter for the ADVIA 120 but not for the LH 750 instrument?
(Multiple Choice)
4.7/5
(38)
Which parameter does the Coulter LH 750 instrument derive from a histogram?
(Multiple Choice)
4.9/5
(35)
Which instrument does not use fluorescence intensity in its determination of reticulocytes?
(Multiple Choice)
4.9/5
(37)
What is the principle of impedance?
Name at least two instruments that employ this method for blood cell counting.
(Essay)
4.7/5
(40)
Which of the following instruments uses both electromechanical and optical density as a means of clot detection?
(Multiple Choice)
4.8/5
(32)
What cellular characteristic is evaluated by radio frequency?
(Multiple Choice)
4.8/5
(33)
Which analyzer measures platelets in the same channel as reticulocytes?
(Multiple Choice)
4.9/5
(42)
Which parameter does the Sysmex XE-2100 instrument determine by using light-scattering and fluorescence intensity characteristics?
(Multiple Choice)
4.8/5
(30)
D-dimers are measured by which method on the Trinity Biotech AMAX Destiny Plus?
(Multiple Choice)
4.9/5
(47)
Which analyzer does not use cyanide-free detection of hemoglobin?
(Multiple Choice)
5.0/5
(30)
When using the CELL-DYN Sapphire to perform CBCs,a laboratory professional can choose to run the ImmunoPlt assay if:
(Multiple Choice)
4.9/5
(38)
Which instrument utilizes contour gating to classify different leukocyte cell types?
(Multiple Choice)
4.8/5
(30)
Which of the following instruments is capable of performing electromechanical,optical density,chromogenic,and immunologic methodologies?
(Multiple Choice)
4.9/5
(32)
In the reticulocyte determination,using the Sysmex XE-2100,the fluorescent dye containing oxazine and polymethine penetrates the cell membranes and stains the blood cells.What does the oxazine bind to within the cells?
(Multiple Choice)
4.8/5
(32)
Compare and contrast the methods of detection for the following analyzers:
a.Sysmex XE-2100
b.Abbott Cell-Dyn Sapphire
c.Coulter LH 780
d.Advia 2120
(Essay)
4.9/5
(30)
The principle that relies on detecting resistance as cells pass through a photo-detector and is used by most of the major hematology analyzers is:
(Multiple Choice)
4.8/5
(37)
Showing 21 - 38 of 38
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)