Exam 39: Automation in Hematology

arrow
  • Select Tags
search iconSearch Question
flashcardsStudy Flashcards
  • Select Tags

Regarding the CELL-DYN Sapphire,which parameter is determined by the impedance principle?

(Multiple Choice)
4.9/5
(47)

The Sysmex XE-2100 instrument printout reports a middle fluorescent ratio of 7.0 and a high fluorescent ratio of 1.3.What is the immature reticulocyte fraction?

(Multiple Choice)
4.9/5
(34)

Which of the following is a reported parameter for the ADVIA 120 but not for the LH 750 instrument?

(Multiple Choice)
4.7/5
(38)

Which parameter does the Coulter LH 750 instrument derive from a histogram?

(Multiple Choice)
4.9/5
(35)

Which instrument does not use fluorescence intensity in its determination of reticulocytes?

(Multiple Choice)
4.9/5
(37)

What is the principle of impedance? Name at least two instruments that employ this method for blood cell counting.

(Essay)
4.7/5
(40)

Which of the following instruments uses both electromechanical and optical density as a means of clot detection?

(Multiple Choice)
4.8/5
(32)

What cellular characteristic is evaluated by radio frequency?

(Multiple Choice)
4.8/5
(33)

Which analyzer measures platelets in the same channel as reticulocytes?

(Multiple Choice)
4.9/5
(42)

Which parameter does the Sysmex XE-2100 instrument determine by using light-scattering and fluorescence intensity characteristics?

(Multiple Choice)
4.8/5
(30)

D-dimers are measured by which method on the Trinity Biotech AMAX Destiny Plus?

(Multiple Choice)
4.9/5
(47)

Which analyzer does not use cyanide-free detection of hemoglobin?

(Multiple Choice)
5.0/5
(30)

When using the CELL-DYN Sapphire to perform CBCs,a laboratory professional can choose to run the ImmunoPlt assay if:

(Multiple Choice)
4.9/5
(38)

Which instrument utilizes contour gating to classify different leukocyte cell types?

(Multiple Choice)
4.8/5
(30)

Which of the following instruments is capable of performing electromechanical,optical density,chromogenic,and immunologic methodologies?

(Multiple Choice)
4.9/5
(32)

In the reticulocyte determination,using the Sysmex XE-2100,the fluorescent dye containing oxazine and polymethine penetrates the cell membranes and stains the blood cells.What does the oxazine bind to within the cells?

(Multiple Choice)
4.8/5
(32)

Compare and contrast the methods of detection for the following analyzers: a.Sysmex XE-2100 b.Abbott Cell-Dyn Sapphire c.Coulter LH 780 d.Advia 2120

(Essay)
4.9/5
(30)

The principle that relies on detecting resistance as cells pass through a photo-detector and is used by most of the major hematology analyzers is:

(Multiple Choice)
4.8/5
(37)
Showing 21 - 38 of 38
close modal

Filters

  • Essay(0)
  • Multiple Choice(0)
  • Short Answer(0)
  • True False(0)
  • Matching(0)